DNP objects supported

Default Variation Window
Page 1 of 4
DNP Add-On: Default Variation Window
This window is used to configure the Default Variation of each one of the Objects.
Station Name
Combo Box that shows the different choices for Object 1 (Binary Input) that the user can select as a default
variation.
Combo Box that shows the different choices for Object 2 (Binary Input Change Events) that the user can select as
a default variation.
Combo Box that shows the different choices for Object 10 (Binary Output) that the user can select as a default
variation.
Combo Box that shows the different choices for Object 30 (Analog Input) that the user can select as a default
variation.
Combo Box that shows the different choices for Object 31 (Frozen Analog Input) that the user can select as a
default variation (only on Level 2+).
Combo Box that shows the different choices for Object 32 (Analog Input Change Events) that the user can select
as a default variation.
Combo Box that shows the different choices for Object 33 (Frozen Analog Input Change Event) that the user can
mk:@MSITStore:C:\Program%20Files%20(x86)\Sixnet%20Tools\Programs\DNPAddOn.... 3/18/2015
Default Variation Window
Page 2 of 4
select as a default variation (only on Level 2+).
Combo Box that shows the different choices for Object 40 (Analog Output) that the user can select as a default
variation.
Combo Box that shows the different choices for Object 20 (Binary Counters) that the user can select as a default
variation.
Combo Box that shows the different choices for Object 21 (Frozen Binary Counters) that the user can select as a
default variation.
Combo Box that shows the different choices for Object 22 (Binary Counters Change Events) that the user can
select as a default variation.
Combo Box that shows the different choices for Object 23 (Frozen Binary Counters Change Event) that the user
can select as a default variation (only on Level 2+).
The possible values for Default Variation are shown in the following table:
DNP Type Object
Binary input
Binary input
change
Binary
Output
Binary
Counter
Frozen
Binary
counter
1
2
10
20
21
Variation
Level
2
Level2+
Description
1
2
1
2
1
1
2
2
3
3
Binary Input Change
without Time
Binary Input Change with
Time
Binary Input Change with
Relative Time
2
1
2
Binary Output
Binary Output Status
1
2
1
2
5
5
6
6
32-Bit Binary Counter
16-Bit Binary Counter
32-Bit Binary Counter
without Flag
16-Bit Binary Counter
without Flag
1
2
1
2
9
5
10
6
9
10
Binary Input
Binary Input with Status
32-Bit Frozen Counter
16-Bit Frozen Counter
32-Bit Frozen Counter
with Time of Freeze
16-Bit Frozen Counter
with Time of Freeze
32-Bit Frozen Counter
without Flag
16-Bit Frozen Counter
without Flag
mk:@MSITStore:C:\Program%20Files%20(x86)\Sixnet%20Tools\Programs\DNPAddOn.... 3/18/2015
Default Variation Window
Binary
Counter
Event
Page 3 of 4
1
1
2
2
22
5
6
1
Frozen
Binary
counter
events
2
23
5
6
Analog Input
30
1
2
1
2
3
3
4
4
5
6
1
2
3
Frozen
Analog Input
4
31
5
6
7
8
1
1
2
2
3
Analog Input
Event
4
32
5
6
32-Bit Counter Change
Event without Time
16-Bit Counter Change
Event without Time
32-Bit Counter Change
Event with Time
16-Bit Counter Change
Event with Time
32-Bit Frozen Counter
Event without Time
16-Bit Frozen Counter
Event without Time
32-Bit Frozen Counter
Event with Time
16-Bit Frozen Counter
Event with Time
32-Bit Analog Input
16-Bit Analog Input
32-Bit Analog Input
without Flag
16-Bit Analog Input
without Flag
Short Floating Point
Analog Input
Long Floating Point
Analog Input
32-Bit Frozen Analog
Input
16-Bit Frozen Analog
Input
32-Bit Frozen Analog
Input with Time of Freeze
16-Bit Frozen Analog
Input with Time of Freeze
32-Bit Frozen Analog
Input without Flag
16-Bit Frozen Analog
Input without Flag
Short Floating Point
Frozen Analog Input
Long Floating Point
Frozen Analog Input
32-Bit Analog Change
Event without Time
16-Bit Analog Change
Event without Time
32-Bit Analog Change
Event with Time
16-Bit Analog Change
Event with Time
Short Floating Point
Analog Change Event
without Time
Long Floating Point
Analog Change Event
without Time
Short Floating Point
Analog Change Event
mk:@MSITStore:C:\Program%20Files%20(x86)\Sixnet%20Tools\Programs\DNPAddOn.... 3/18/2015
Default Variation Window
Page 4 of 4
7
8
1
2
3
4
Frozen
Analog Input
Event
33
5
6
7
8
1
Analog
Output
40
2
2
3
4
with Time
Long Floating Point
Analog Change Event
with Time
32-Bit Frozen Analog
Event without Time
16-Bit Frozen Analog
Event without Time
32-Bit Frozen Analog
Event with Time
16-Bit Frozen Analog
Event with Time
Short Floating Point
Frozen Analog Change
Event without Time
Long Floating Point
Frozen Analog Change
Event without Time
Short Floating Point
Frozen Analog Change
Event with Time
Long Floating Point
Frozen Analog Change
Event with Time
32-Bit Analog Output
Status
16-Bit Analog Output
Status
Short Floating Point
Long Floating Point
Related Topics
DNP
DNP
DNP
DNP
DNP
Add-On:
Add-On:
Add-On:
Add-On:
Add-On:
DNP General Properties Window
Physical Link Layer Properties Window
Data Link Layer Properties Window
Application Layer Properties Window
Object Mapping Window