1. PART NUMBER CODE 2. MARKING 3. Outline Drawing

Unictron Technologies Corporation
Product :Gas Discharge Tube
Part No.: JN2R2500A6L
1. PART NUMBER CODE
JN
2500
2R
Brand
N am e
2 Elem ents
M ini H igh
Voltage Series
A
AC PA2R 2500
3. Outline Drawing
Unit: mm
Item
Dimensions
D
5.5 +0.3,-0.5
T
6.0+0.3,-0.5
d
0.8±0.05
L
20min.
L
D iam eter
5.5m m
DC
Breakdow n
Voltage
2. MARKING
6
Length
6m m
Lead Type
0.8m m
lead
diam eter
Rev. 1.0
Page
1/3
Unictron Technologies Corporation
Product :Gas Discharge Tube
Rev. 1.0
Part No.: JN2R2500A6L
Page
2/3
4. SPECIFICATION
4.1ELECTRICA L SPECIFICATION
Model
DC
Maximum
Maximum
Normal
Impulse
DC
Minimum
Maximum
Name
Breakdown
Impulse
Impulse
Alternating
Life
Holdover
Insulation
Capacitance
Voltage
Breakdown
Discharge
Dischar ge
Voltage
Resistance
Voltage
Current
Current
(100A)
(V)
(GΩ)
times
<150ms
300
150
(8/20 µs)
(V)
100V/s
2 R -2500 2500 ±20%
100V/µs 1000V/µs 1 time
3500
(A)
(KA)
(V)
3300
10/1000µs
3
10
50Hz,
Single
times
1sec
9cycles
1.5
2
4
4.2 Standard Bulk Packaging Specifications
Quantity: 100 pieces per plastic tray
500 pieces per inner box
10 inner boxes per carton
5000 pieces per full carton
(pf)
1MHZ
1
1
Unictron Technologies Corporation
Product :Gas Discharge Tube
Part No.: JN2R2500A6L
Rev. 1.0
Page
3/3
5. ELECTRICAL RATING
Item
DC Breakdown
Test Condition / Description
Requirement
The voltage measured at a rise time of 100v/s.
Voltage
Maximum Impulse The maximum breakdown voltage at rise times of 100v/us and 1000v/us.
Breakdown
Voltage
The maximum current applying a waveform of 8/20us that can be applied
Maximum Impulse across the terminals of the gas tube without causing the gas tube to
Discharge Current change more than ±25% from its initial measured DC breakdown
voltage. Dwell time between pulses is 3 minutes.
Rated RMS value of AC current at 50Hz, 1 sec. 10 times. Intervals: 3min.
Alternating
DC breakdown voltage may not change more than ±25% from its initial
Discharge Current measured DC breakdown voltage. IR > 108 ohms (-20%, +30% for 70 –
90V).
Impulse Life
The minimum number of impulses of a specified waveform and peak
current which a gas tube will conduct without causing the gas tube to
change more than ±25% from its initial measured DC breakdown voltage.
Dwell time between pulses is 1-2 minutes.
DC Holdover
Voltage
The maximum DC voltage across the two terminals of the gas tube under
which it may be expected to return to the high impedance state after the
gas tube breakdown.
The resistance of the gas tube shall be measured each terminal to each
other terminal.
DC Breakdown Voltage
Measuring Voltage
Insulation
70-150V
50V
Resistance
151-400V
100V
470-1000V
250V
1001-2000V
500V
2001-6000V
1000V
Capacitance
The capacitance of a gas tube shall be measured each terminal to each
other terminal. Test frequency:
1MHz In measurements involving 3-electrode gas tubes, the terminal not
being tested shall be connected
to a ground plane.
To meet the
specified value