High Power Contacts VPC’s new 150 Amp contact is designed for high amperage and power testing applications. Features and Benefits • High Power/Current contacts rated up to 150 Amps* • Safety Interlock can be wired with use of our TriPaddle contacts • Contacts are IP rated 2X when fully assembled • 6 position Standard/90 Series with strain relief • 4 position iCon modules for use in i1 or iCon connector** • Up to 10,000 cycles *Tested and designed to use with Cooner Wire CW6044-14(UL Rated), AS 105-14(Non-UL), or equivalent. **Some physical limitations may apply and additional parts may be needed, please consult VPC for assistance in maximizing your system’s performance. VIRGINIA PANEL CORPORATION vpc.com 1/22/14 High Power Contacts Specifications Operating Current 150 Amp Continuous using 2 AWG wire Contact Resistance 0.35 mOhms Mating Force 2.5 lbs Max [1.13 Kg] Operating Voltage 600V Contact Body Cu Alloy Contact Plating Receiver Body - 10µ" Au over 100µ" Ni Internal Contact Beams - Ag over Ni Contact Plating ITA Body - 30µ" Au over 100µ" Ni Operating Temperature -40°C to 125°C T-Rise +40°C at 150 Amps Contact Termination Crimp Cycle Life 10,000 cycles ITA Contact, Part # 610 150 101 Receiver Contact, Part # 610 149 101 5.89 .232 11.12 .438 8.83 .348 5.72 .225 8.83 .348 12.70 .500 36.20 1.425 37.47 1.475 11.12 .438 12.70 .500 Pa r t # Description 610 149 101* 610 150 101* 7-221 902 000-036 7-222 902 000-036 510 104 307 510 108 281 510 160 124** 510 161 124** 510 109 549 910 102 116 910 102 117 910 112 129 High Power Contact, Receiver, 150 Amp, 2 AWG, 10µ" Gold High Power Contact, ITA, 150 Amp, 2 AWG, 30µ" Gold High Power Patchcord, Receiver, 150 Amp, 36", 2 AWG, Single Ended High Power Patchcord, ITA, 150 Amp, 36", 2 AWG, Single Ended High Power Module, Receiver, 6 Position High Power Module, ITA, 6 Position High Power Module, Receiver, iCon, 4 Position High Power Module, ITA, iCon, 4 Position Strain Relief Plate for High Power Standard/90 Series ITA and Receiver Modules Tool, Crimp Kit (Pneumatic Crimp Tool, Locator, and Die), High Power, Receiver and ITA Tool, Crimp Kit (Locator and Die), High Power, Receiver and ITA Tool, Extraction, High Power, Receiver and ITA *Tested and designed to use with Cooner Wire CW6044-14(UL Rated), AS 105-14(Non-UL), or equivalent. **Some physical limitations may apply and additional parts may be needed, please consult VPC for assistance in maximizing your system’s performance. For multiple conductor correction factors please reference http://www.coonerwire.com/amp-chart/. VIRGINIA PANEL CORPORATION vpc.com 1/22/14