PART # 610 115 124 / 610 115 125
Dimensions shown: [millimeters]
inches
ASSEMBLY INSTRUCTIONS
1. Strip wire (Figure A).
2. Insert a piece of 0.25” [6.35 mm] diameter shrink tubing 1.00”
[25.4 mm] long onto wire.
3. Solder and clean (Figure B). VPC solders per IPC’S J-STD-001.
NOTE: Make sure the heat from the solder does not shrink the
tubing.
Figure A. Strip length.
4. Slide the piece of shrink tubing over the soldered end, up to
the inspection hole; make sure that the inspection hole is not
covered (Figure C).
5. Shrink the tubing.
Figure B. Solder, taking care not to shrink the tubing.
Figure C. Ensure inspection hole is not covered.