high power standard/90 series module installation and removal

HIGH POWER CONTACTS AND MODULES USER’S MANUAL: SECTION 4
VIRGINIA PANEL CORPORATION
HIGH POWER STANDARD/90 SERIES MODULE INSTALLATION AND REMOVAL
TOOLS REQUIRED
3
/32 Allen Wrench
In-lbs Torque Driver
INSTALLATION INSTRUCTIONS
1. Place the module in the receiver or ITA until the upper and
lower module screws touch the mating holes in the inner
frame. Ensure that Position 1 is located at the top for systems
in which the modules are oriented vertically or to the left for
systems in which the modules are oriented horizontally.
2. Using a 3/32 Allen wrench, tighten the top screw (4-40 x 5/8 captive
screw for the receiver module and 4-40 x 9/16 captive screw for
ITA module)1 to 2 full revolutions, while pushing lightly against the
face of the
module.
3. Maintain this pressure while tightening the bottom screw 1 to
2 full revolutions.
4. Repeat this sequence until the module is seated. Tighten screws
to a maximum torque of 4 in-lbs [0.45 Nm].
REMOVAL INSTRUCTIONS
1. To remove, loosen the top screw (4-40 x 5/8 captive screw for the
receiver module and 4-40 x 9/16 captive screw for ITA module)
1 to 2 full revolutions. Loosen bottom screw 1 to 2 full revolutions.
Figure A. Receiver Module.
2. Repeat this sequence until the module is separated from the
receiver or ITA.
NOTE: For optimum performance and system longevity, distribute
the contact load evenly throughout the module.
Figure B. ITA Module.
4-1
For more information visit vpc.com
11/25/2014