Winchester Electronics Presents... Customized Fujikura Fusion Splicer Winchester Electronics has partnered with the global leader in fusion splicing technology, AFL Telecommunications, to design a customized Winchester KINGS® Brand, Fujikura fusion splicer for our HDTV Fiber Optic Tri-Loc® Camera Connectors and EL-Series™ Video Patching System. This partnership provides Winchester customers with the best performance and value in the industry. Our fixed V-groove and core alignment models incorporate a user-friendly interface with enhanced features to provide the most rugged and reliable fusion splicers in the market today. The new rugged construction adds improved reliability by resisting shock, dust, and rain, and can withstand a 30” drop test. Product Benefits: Dual purpose design enables quick and easy conversion between standard single fiber fusion splicing and Winchester’s fiber splicing needs. Rugged construction providing shock, dust, and moisture resistance. Dual monitor position with automatic image orientation. Automatic arc calibration and fiber identification. User-selectable fiber clamping method - sheath clamp or fiber holders. Rugged SMPTE 311 cable holder for ease of use during splicing in the field. Auto-start tube heater feature. Color LCD display with anti-reflective coating for excellent visibility in bright sunlight. Simultaneous battery charge and splicer operation. Long battery life (up to 160 splice/heat cycles per charge). Detachable work table incorporated into the transit case. Data and video download software included; software upgrade available via the internet. Green friendly - RoHS & WEEE compliant. July 2011 www.winchesterelectronics.com Parts and Accessories Fusion Splicer Kit with Winchester KINGS® Fiber Optic Tri-Loc® Modification (with cleaver) Includes: CT30A Cleaver, ADC-13 AC Adapter, ACC-14 AC Cord, Spare Electrodes (pair),Sheath Clamp, USB Cable, Splicer Carrying Strap, Quick Reference Guide, Video Instruction Manual, JP-05 Splice Sleeve Cooling Tray, and Transit Case with Carrying Strap Fusion Splicer Kit with Winchester KINGS® Fiber Optic Tri-Loc® Modification (with cleaver, battery and cord) Includes: BTR-08 Battery, DCC-14 Battery Charge Cord, CT30A Cleaver, ADC-13 AC Adapter, ACC-14 AC Cord, Spare Electrodes (pair), Sheath Clamp, USB Cable, Splicer Carrying Strap, Quick Reference Guide, Video Instruction Manual, JP-05 Splice Sleeve Cooling Tray, and Transit Case with Carrying Strap Accessories for FSM-18S/60S FSM-18S V-Groove FSM-60S Core Alignment KTH-2315 KTH-2328 KTH-2330 KTH-2329 Part Number Cable Clamp for Fiber Optic Tri-Loc® Cable KTH-2331 Fiber Holder for Fiber Optic Tri-Loc Cable KTH-2332 Fiber Holder for Fiber Optic Tri-Loc® Termini KTH-2333 ® Fiber Optic Tri-Loc Modification Upgrade for Standard FSM-60S/18S KTH-2334 Fiber Holder for EL Series™ DIN Terminal KTH-2335 CT-30A Cleaver (SO14080) Single Fibers: 250-900µm coating, 125µm cladding KTH-2340 Fiber Optic Tri-Loc CT-30A Cleaver Base / Use with Cable Clamp KTH-2341 ® ® Specifications Model FSM-18S FSM-60S Cladding Diameter 125μm 100μm to 1,000μm Typical Average Splice Loss 0.05dB with SM, 0.02dB with MM, 0.08dB with DS, 0.08dB with NZDS, measured by cut-back method relevant to ITU-T and IEC standards 0.02dB with SM, 0.01dB with M , 0.04dB with DS, 0.04dB with NZDS. Measured by cut-back method relevant to ITU-T and IEC standards Splicing Time Typical 11 seconds with standard single-mode fiber Typical 9 seconds with standard single-mode fiber Splice Loss Estimate Based upon dual camera cladding axis alignment data Based upon dual camera core alignment data Operating Condition 0 to 3,660m above sea level, 0 to 95% RH, -10 to 50°C respectively 0 to 5,000m above sea level, 0 to 95%RH and -10 to 50°C respectively Splice/Heat Cycles w/ Battery Typical 150 cycles with power save functions activated Typical 160 cycles with power save functions activated Weight 2.1 kg (4.6 lbs) with AC adapter ADC-11; 2.5kg (5.5 lbs) with BTR-08 battery 2.3 kg (5.1 lbs) with AC adapter ADC-11; 2.7kg (5.9 lbs) with BTR-08 battery Applicable Fibers Single-mode (ITU-T G.652), multimode (ITU-T G.651), DS (ITU -T G.653), NZDS (ITU-T G.655) Coating Diameter 100μm to 1000μm Fiber Cleave Length 8 to 16mm with 250μm coating diameter, 16mm with 900μm coating diameter Arc Calibration Method Automatic, real-time by using results of previous splice when in AUTO mode; manual arc calibration function available Splicing Modes 100 preset and user programmable modes Storage of Splice Result Last 2000 results to be stored in the internal memory Fiber Display X or Y, or both X and Y simultaneously; front or rear monitor display options with automated image orientation Magnification 300X for single X or Y view, or 187X for X and Y view Viewing Method Dual cameras with 4.1 inch TFT color LCD monitor with anti-reflective coating Mechanical Proof Test 1.96 to 2.25N Tube Heater Built-in tube heater with 30 heating modes; auto-start function Tube Heating Time Typical 30 seconds with FP-03 sleeve, 35 seconds with FP3 (40), 35-55 seconds with Fujikura micro sleeves Protection Sleeve Length 60mm, 40mm, micro Power Supply Auto voltage selection from 100 to 240V AC or 10 to 15V DC with ADC-1, 13.2V DC with BTR-08 battery Terminals USB 1.1 (USB-B type) for PC communication, Mini-DIN (6-pin) for HJS-02/03 and SH-8 tube heater Wind Protection Maximum wind velocity of 15m/s. (34 mph) Dimensions 136W x 161D x 143H (mm) / 5.3W x 6.3D x 5.6H (inches) 62 Barnes Industrial Road North Wallingford, CT 06492 Phone: (203) 741-5400 • Fax: (203) 741-5500