Enclosed Power Supplies TXL Series, 15–1000 Watt Features ◆ Compact metal case with screw terminal block ◆ Dual and triple output models with isolated outputs ◆ Universal input 85–264 VAC ◆ EMI/EMC compliance with EN 61000-6-3 and EN 61000-6-1 ◆ Compliance to EN 61000-3-2 (PFC) ◆ Short circuit and overvoltage protection ◆ International safety approvals ◆ 3-year product warranty The TRACOPOWER TXL series is a family of encased power supplies designed for a wide range of cost critical applications. With a low profile metal case and screw terminal block connection, they are easy to install in any equipment. There are 64 models in this range with single, dual, and triple output voltages from 3.3 VDC to 48 VDC in 12 power ranges from 15 W to 1000 W. These power supplies have universal input and comply with European EMC standards and the Low Voltage Directive (LVD). Models with Single Output Order Code Case Type Output Power max. Output Voltage nom. Output Current max. TXL 015-3.3S 3.3 VDC 3.0 A TXL 015-05S 5 VDC 3.0 A TXL 015-12S 12 VDC 1.3 A TXL 015-15S B 15 Watt 15 VDC 1.0 A TXL 015-24S 24 VDC 0.63 A TXL 015-48S 48 VDC 0.32 A TXL 025-3.3S 3.3 VDC 6.0 A TXL 025-05S 5 VDC 5.0 A 12 VDC 2.1 A 15 VDC 1.7 A TXL 025-24S 24 VDC 1.1 A TXL 025-48S 48 VDC 0.57 A TXL 035-3.3S 3.3 VDC 9.0 A TXL 035-05S 5 VDC 7.0 A TXL 035-12S 12 VDC 3.0 A 15 VDC 2.4 A 24 VDC 1.5 A TXL 035-48S 48 VDC 0.8 A TXL 050-05S 5 VDC 10.0 A TXL 060-12S 12 VDC 5.0 A 15 VDC 4.0 A 24 VDC 2.5 A TXL 025-12S TXL 025-15S C 35 Watt TXL 035-15S TXL 035-24S TXL 060-15S TXL 060-24S http://www.tracopower.com 25 Watt D 50 / 60 Watt Page 1 of 11 Enclosed Power Supplies TXL Series 15–1000 Watt Models with Single Output Order Code Case Type TXL 060-3.3S TXL 060-05S TXL 070-12S TXL 070-15S TXL 070-24S TXL 070-48S TXL 100-3.3S TXL 100-05S TXL 100-12S TXL 100-15S TXL 100-24S TXL 100-48S TXL 150-05S TXL 150-12S TXL 150-24S TXL 150-48S TXL 230-12S* TXL 230-24S* TXL 230-48S* TXL 350-24S* TXL 350-48S* TXL 750-24S* TXL 750-48S* TXL 1000-24S* TXL 1000-48S* Output Power max. 60 / 70 Watt E J 100 Watt L 150 Watt N 230 Watt O 350 Watt P 750 Watt Q 1000 Watt Output Voltage nom. 3.3 VDC 5 VDC 12 VDC 15 VDC 24 VDC 48 VDC 3.3 VDC 5 VDC 12 VDC 15 VDC 24 VDC 48 VDC 5 VDC 12 VDC 24 VDC 48 VDC 12 VDC 24 VDC 48 VDC 24 VDC 48 VDC 24 VDC 48 VDC 24 VDC 48 VDC Output Current max. 15.0 A 12.0 A 6.0 A 4.8 A 3.0 A 1.5 A 23.0 A 20.0 A 8.5 A 7.0 A 4.3 A 2.3 A 30.0 A 12.5 A 6.3 A 3.2 A 19.2 A 9.6 A 4.8 A 14.7 A 7.5 A 31.3 A 15.8 A 40.0 A 21.0 A * with internal fan (see dimensions) Models with Multiple Output Order Code Case Type TXL 035-0512D TXL 035-0524D TXL 035-1212D TXL 035-1515D TXL 060-0512DI TXL 060-0524DI TXL 060-0521TI TXL 060-0522TI TXL 060-0533TI TXL 060-0534TI TXL 100-0512DI TXL 100-0524DI TXL 100-0521TI TXL 100-0522TI TXL 100-0533TI TXL 100-0534TI Output Power max. D 35 Watt E 60 Watt J 100 Watt * Output1 (Main Output) +5 VDC/ 4.0 A +5 VDC/ 4.0 A +12 VDC/ 3.0 A +15 VDC/ 2.4 A 5 VDC/ 8.0 A 5 VDC/ 6.0 A 5 VDC/ 8.0 A 5 VDC/ 7.0 A 5 VDC/ 7.0 A 5 VDC/ 6.0 A 5 VDC/ 12.0 A 5 VDC/ 12.0 A 5 VDC/ 12.0 A 5 VDC/ 12.0 A 5 VDC/ 12.0 A 5 VDC/ 12.0 A * Output 2 +12 VDC/ 2.5 A +24 VDC/ 1.3 A –12 VDC/ 1.5 A –15 VDC/ 1.5 A 12 VDC/ 4.0 A 24 VDC/ 2.2 A 12 VDC/ 3.5 A 12 VDC/ 3.5 A 15 VDC/ 3.0 A 12 VDC/ 1.5 A 12 VDC/ 7.0 A 24 VDC/ 3.5 A 12 VDC/ 5.0 A 12 VDC/ 5.0 A 15 VDC/ 4.0 A 12 VDC/ 4.0 A * Output 3 5 VDC/ 1.0 A 12 VDC/ 1.0 A 15 VDC/ 1.0 A 24 VDC/ 1.2 A 5 VDC/ 1.5 A 12 VDC/ 1.5 A 15 VDC/ 1.5 A 24 VDC/ 2.0 A * Total power must not exceed specified max. output power http://www.tracopower.com Page 2 of 11 Enclosed Power Supplies TXL Series 15–1000 Watt Input Specifications Input voltage range – nominal – AC range (universal input) – DC range 100 – 240 VAC 85 – 264 VAC for 15 to 350 Watt model 90 – 264 VAC for 750 & 1000 Watt models 120 – 375 VDC for 15 to 350 Watt model 127 – 375 VDC for 750 & 1000 Watt models Input voltage frequency 47 – 63 Hz Input current (at full load) TXL 015/025 models: TXL 035 models: TXL 060/070 models: TXL 100 models: TXL 150 models: TXL 230 models: TXL 350 models: TXL 750 models: TXL 1000 models: Vin = 115 VAC 0.50 A typ. 0.70 A typ. 1.00 A typ. 1.65 A typ. 2.10 A typ. 3.20 A typ. 3.30 A typ. 8.0 A typ. 11.0 A typ. Vin = 230 VAC 0.22 A typ. 0.42 A typ. 0.60 A typ. 0.95 A typ. 1.10 A typ. 1.70 A typ. 1.70 A typ. 3.90 A typ 5.0 A typ. Input current (at no load) TXL 015/025 models: TXL 035 models: TXL 230/350 models: TXL 750 models: TXL 1000 models: other models: Vin = 115 VAC 10 mA typ. 50 mA typ. 115 mA typ. 210 mA typ. 330 mA typ. 100 mA typ. Vin = 230 VAC 17 mA typ. 55 mA typ. 140 mA typ. 220 mA typ. 350 mA typ. 80 mA typ. Recommended circuit breaker up to 70 Watt models: 5 A (characteristic C) or slow blow fuse up to 350 Watt models: 10 A TXL 750 & 1000 Watt models: 16 A Output Specifications Output voltage adjustment range ±10 % – 35 Watt dual output models: range Vout 1–2 – other multi output models: Vout 1 Regulation – Input variation – Load variation (10–100%) single output models: multiple output models: – Minimum load on main output of multiple output models: (to provide the regulation on the auxilary outputs) 1 % max. 2 % max. 4 % max. for main output 6 % max. for output 2/3 (20–100 % load) 0.3 A for TXL 035 1.0 A for TXL 060 1.5 A for TXL 100 Ripple and noise (20 MHz bandwidth) 3.3 VDC output < 50 mV Output 3 (on triple output models) < 1.5 % of Vout all other output voltages < 1.0 % of Vout nom. Output current limitation 105 % – 150 % of Iout max. Overload protection mode Fold back, automatic recovery Over voltage protection (only output 1) 115 % – 140 % of Vout nom. (depending on model) Capacitive load, max. www.tracopower.com/products/txl-capload.pdf http://www.tracopower.com Page 3 of 11 Enclosed Power Supplies TXL Series 15–1000 Watt General Specifications Temperature ranges – Operating –20°C to +70°C – Load derating above +45°C 2 %/°K (2.5 %/°K for TXL 120/230/1000) – Storage (non operating) –14°C to +85°C Temperature coefficient 0.02 %/°C Efficiency 70 – 84 % (depending on model) Humidity (non condensing) 85 % rel max. (non condensing) Switching frequency 50 kHz typ. (pulse width modulation) Hold-up time 20 ms min. Isolation voltage (60 sec.) – Input/Output – Input/Case – Output/Case – Output/Output 60–100 Watt multiple output models: 35 Watt dual output models: 3‘000 VAC 1‘500 VAC 500 VAC 500 VAC (for all outputs of triple output models!) outputs not isolated Reliability /calculated MTBF (MIL-HDBK-217F, at +25°C typ., ground benign) >250’000 h Electromagnetic compatibility – Conducted input RI suppression (EMC), Emissions – Harmonic current emissions – Flicker EN 55022, class B, FCC part 15, level B IEC/EN 61000-3-2, class D (TXL 120/150/220) IEC/EN 61000-3-2, class A (others) IEC/EN 61000-3-3 Electromagnetic compatibility – (EMC), Immunity – – – – – – IEC/EN 61000-4-2 IEC/EN 61000-4-3 IEC/EN 61000-4-4 IEC/EN 61000-4-5 IEC/EN 61000-4-6 IEC/EN 61000-4-8 IEC/EN 61000-4-11 Electrostatic discharge ESD RF field immunity Electrical fast transients/burst immunity Surge Conducted RF Magnetic field Voltage dip 4 kV / 8 kV 3 V/m 1 kV 1 kV / 2 kV 3 V/m 3 A/m Safety standards UL 60950-1, IEC/EN 60950-1 2nd edition Safety approvals – UL/cUL – CB report TXL 015 models: TXL 025 models: TXL 035 models: TXL 060/070 models: TXL 100 models: TXL 150 models: TXL 230 models: TXL 350 models: TXL 750 models: TXL 1000 models: Environmental compliance www.ul.com -> certifications -> File: e188913 www.tracopower.com/products/txl015-cb.pdf www.tracopower.com/products/txl025-cb.pdf www.tracopower.com/products/txl035-cb.pdf www.tracopower.com/products/txl060-cb.pdf www.tracopower.com/products/txl100-cb.pdf www.tracopower.com/products/txl150-cb.pdf www.tracopower.com/products/txl230-cb.pdf www.tracopower.com/products/txl350-cb.pdf www.tracopower.com/products/txl750-cb.pdf www.tracopower.com/products/txl1000-cb.pdf – Reach www.tracopower.com/overview/txl – RoHS RoHS directive 2011/65/EU Casing material TXL 025/035 nickel plated steel (chassis & cover) TXL 50/60/70/100aluminium (chassis), nickel plated steel (cover) othersaluminium (chassis & cover) All specifications valid at nominal input voltage, full load and +25°C after warm-up time unless otherwise stated. http://www.tracopower.com Page 4 of 11 Enclosed Power Supplies TXL Series 15–1000 Watt Case Dimensions 15.1 2x M3 THD 11.5 (0.45) (2.44) Top view (0.99) Vout 2 x M3 THD (bottom) 25.25 L N + Weight: 0.13 kg (4.6 oz) 39.1 14.7 (1.54) (0.58) 51 62 (0.55 max.) (2.01) 14 max. 39.1 (1.54) (0.59) Case B 28.0 (1.10) 65 (2.56) 14.5 2x M3 THD (0.57) Case C 3 (0.12) (3.11) L N 2 x M3 THD (bottom) Top view (1.0) 25.5 Vout Weight: 0.19 kg (6.7 oz) (2.01) 79 (0.55 max.) 51 14 max. 55 11 28.5 (2.17) (0.43) (1.12) 1 AC L AC L 2 AC N AC N 3 AC FG AC FG 4 –Vout Common 5 +Vout Vout 1 6 No con. Vout 2 74 10 max. (0.28) (3.90) (0.39 max.) 0.3 kg (10 oz) Max mounting screw penetration: 2.0 mm (0.08) http://www.tracopower.com 99 7 (2.91) 1 2 3 4 5 6 2 x M3 THD (bottom) Top view 55 (2.17) 23.5 (0.93) 82 (3.23) dual 45 (1.77) single (0.69) 2x M3 THD Connection Weight: 17.5 Case D 35 (1.38) Page 5 of 11 Enclosed Power Supplies TXL Series 15–1000 Watt Case Dimensions * Opposite polarity for TXL 060-0534TI Weight: 10 max. 19 (0.75) 159 (6.26) (0.39 max.) 1 2 3 4 5 6 7 8 9 1 2 3 4 5 6 7 Dual & Triple output models 0.7 kg (25 oz) 118 (4.65) 19 AC L AC N AC FG +Vout 3* –Vout 3* –Vout 1 +Vout 1 –Vout 2 +Vout 2 (0.75) AC L AC N AC FG No con. No con –Vout 1 +Vout 1 –Vout 2 +Vout 2 Top view 2 x M3 THD (bottom) Single output (3.74) AC L AC N AC FG –Vout –Vout +Vout +Vout – – 95 Triple (1.26) Dual 10 18 Single 32 1 2 3 4 5 6 7 8 9 3 x M3 THD (0.39) Connection (0.71) Case E 78 57 38 (3.07) (0.95) (1.50) Case J AC L AC N AC FG +Vout 3* –Vout 3* –Vout 1 +Vout 1 –Vout 2 +Vout 2 3 x M3 THD 158 20 (6.22) (0.79) 19 AC L AC N AC FG No con. No con –Vout 1 +Vout 1 –Vout 2 +Vout 2 (0.75) AC L AC N AC FG –Vout –Vout +Vout +Vout – – 10 Triple (0.39) Dual 18 1 2 3 4 5 6 7 8 9 Single (0.71) Connection * Opposite polarity for TXL 100-0534TI 10 max. 198 (7.80) (0.39 max.) Weight: 0.8 kg (28 oz) Single output 120 (4.72) (3.74) 80 4 x M3 THD (bottom) 95 (3.15) Top view (0.35) Dual & Triple output models 1 2 3 4 5 6 7 9 1 2 3 4 5 6 7 8 9 16.5 (0.45) 38 (1.50) Max mounting screw penetration: 3.0 mm (0.12) http://www.tracopower.com Page 6 of 11 Enclosed Power Supplies TXL Series 15–1000 Watt Case Dimensions 6 x M4 THD (0.49) 12.5 Case L (2.20) (0.98) 25 176.5 13 max. 56 (4.61) RC Remote Control On/Off: RC+/RC–: 0–0.7 V = On 3–10 V = Off. RS Remote Sense Can be open or connected to the load under regard of polarity (0.49) 117 12.5 21 (0.83) Connector 11.5 (6.95) (0.45) 198 (7.83) (0.51 max.) 168 63 (2.48) (6.61) 10 49.5 (1.95) 99 (3.9) (3.11) (2.56) 28 2 x M4 thread (bottom) 65 Weight: 79 N L Top view (1.10) 4 x M3 THD (bottom) 10 Vout V adj. RC + RS + (0.39) + + 50 (1.97) (0.39) 0.89 kg (31 oz) 4x TXL-CMB chassis mount brackets included in shipment http://www.tracopower.com Max mounting screw penetration: 3.0 mm (0.12) Page 7 of 11 Enclosed Power Supplies TXL Series 15–1000 Watt (0.49) 6 x M4 THD 12.5 Case N air flow Outline Dimensions 11.5 176.5 (6.95) 12 max. (0.98) 25 56 (2.20) RC Remote Control On/Off: RC+/RC–: 0–0.7 V = On 3–10 V = Off. RS Remote Sense Can be open or connected to the load under regard of polarity (0.49) 117 (4.61) 12.5 21 (0.83) Connector (0.45) 198 (7.8) (0.47 max.) V adj. RC + RS + 63 65 (2.56) (2.48) 168 (6.61) Weight: (1.95) 28 N L (1.10) 2 x M4 THD (bottom) 49.5 79 (3.11) 4 x M3 THD (bottom) 45 10 + + (0.39) Vout 99 (3.9) Top View (1.77) 10 (0.39) 0.88 kg (30 oz) 4x TXL-CMB chassis mount brackets included in shipment 12 max. (1.16) 212 (0.98 ±0.03) 29.5 (5.91 ±0.03) (0.49) 150 ±0.8 25 ±0.8 4 x M4 THD 12.5 air flow Case O Connector RC Remote Control On/Off: RC+/RC–: 0–0.7 V = On 3–10 V = Off. RS Remote Sense Can be open or connected to the load under regard of polarity (8.35) (0.47 max.) 150 29.5 (5.91) (1.16) 177.5 (6.99) Weight: 1.05 kg (37 oz) 4x TXL-CMB chassis mount brackets included in shipment http://www.tracopower.com (3.44) 7 (4.53) (1.97) (1.28) 115 50 (0.39) 87.5 95 (3.74) 5 x M3 THD (bottom) 10 N L 54.5 4 x M4 THD (bottom) (2.15) Vout + + + 32.5 V adj. RC + RS + 50 (1.97 ) (0.28) Max mounting screw penetration: 3.0 mm (0.12) Page 8 of 11 Enclosed Power Supplies TXL Series 15–1000 Watt Outline Dimensions Case P Weight: 39 220 16 12.5 30 20 13 3.5 kg (123 oz) 25 210 40 30 29(bottom) 5 240(bottom) 6 (bottom) 40 125 145 S/N LABEL 6 TXL-CMB chassis mount bracket set (4pcs) included in shipment. For dimensions see page 11. 15 220 20 8.5 40 63 air flow 34.5 CN3 210 6 6 113(bottom) 6 (bottom) 125 25 240 M O D E L L AB E L 16.5 113 30 5 16.5 275 Max mounting screw penetration: 3.0 mm (0.12) CN3 pin consideration: Pin 1: Current sharing to interconnect up to 3 units at parallel operation Max power = units x 0.9, max deviation of voltage adjustment among units =100mV Pin 2: Power Good Signal. TTL (3mA max.): 0 – 1 VDC = DC-Off, 3.3 – 5.6 VDC = DC-OK Pin 3/4: Remote sense to be connected at load side under regard of polarity Pin 5/6: Remote control input RC1& RC2 Pin 7/8 Auxillary output 12VDC/0.1A for remote control function Using internal 12V auxiliary output Remote On/Off function: 330Ω RC1 Using external voltage AUX 2KΩ RC2 AUX 2KΩ RC2 SW 12V Connection cable with 500mm flyind leads included! Using internal 12V auxiliary output AUX 2KΩ Mating connector: Housing: HRS DF11-08DS-2C Crimp: HRS DF11-EP22SCB RC1 12V 330Ω SW 470Ω 330Ω SW GND RC2 RC1 12V 5V GND GND Parallel operation: PSU CN3 2 4 6 8 1 3 5 7 +v +v +v -v -v -v PSU CN3 2 4 6 8 1 3 5 7 PSU CN3 +v +v +v -v -v -v 2 4 6 8 1 3 5 7 +v +v +v -v -v -v RS-(PIN4) +V -V RS+(PIN3) LOAD All specifications valid at nominal input voltage, full load and +25°C after warm-up time unless otherwise stated. http://www.tracopower.com Page 9 of 11 Enclosed Power Supplies TXL Series 15–1000 Watt Outline Dimensions 271.7 (10.70) Case Q 17.3 (XXX) (1.00) 40.6 25.4 7.8 (0.31) 3 x M4 THD (0.81) 20.5 (XXX) (both sides) 239.5 (9.43) 34.5 (1.36) 3 x M4 THD (bottom) −V air flow 127.0 (5.00) 68.0 (2.68) LED 1 CN15 CN14 PE air flow L (0.73) 18.5 90.0 (3.54) +V Vadj + N 295.0 (11.61) CN15 8 6 4 2 GND ON/OFF GND −S CS DC_OK 5V_AUX +S Weight: 7 5 3 1 1.9 kg (67 oz) Dimensions in [mm], () = Inch Tolerances ±0.8 (±0.03) Monting hole pich tolerances ±0.5 (±0.02) Caution! Max mounting screw penetration: 3.0 mm (0.12) TXL-CMB1 chassis mount bracket set (4pcs) included in shipment. For dimensions see page 11. CN14 Jumper on CN14 disables the Remote Off function CN15 On/Off (pin 4 & 6): Contact closed = Power On, Contact open = Power Off CN15 –S/+S (pin 1 & 2): Remote sense to be connected at load side under regard of polarity CN15 5V Aux (pin 3 & 8): Auxiliary output 5 VDC / 0.5 A CN15 DC–OK (pin 5 & 8): TTL signal (2.2 mA max.): 0 – 1 VDC = DC–Off, 3.3 – 5.6 VDC = DC–OK CN15 CS (pin 7): Current Sharing to interconnect up to 4 units at parallel operation Max power = units x 0.9, max deviation of voltage adjustment among units =100mV Parallel operation: CN15 7 6 5 4 3 2 1 -S CN15 PS1 8 CS -V +S +V 7 6 5 4 3 2 1 -S CN15 PS2 8 CS -V +V +S PS3 8 7 6 5 4 3 2 1 -S CS -V +V +S -S +S Specifications can be changed any time without notice. LOAD Page 10 of 11 AC/DC Power Modules TXL Series 15–1000 Watt Chassi Mount Brackets Order code: TXL-CMB contains 4pcs brackets and screws 4x7 For series models: •TXL 150; Case L •TXL 230; Case N •TXL 350; Case O •TXL 750; Case P R1 7.5 7.5 7.5 7.5 .5 R0 5.6 5.0 .0 5.0 10.0 The chassi mount brackets are bypacked along with the following models: 17.5 Ø4 12.5 .2 15.0 Order code: TXL-CMB1 contains 4pcs brackets and screws 15.0 16.8 4x7 5.0 For series models: •TXL 1000; Case Q .0 R1 6.9 6.9 2.8 7.8 11.2 12.7 .2 25.4 Ø4 5.6 8.6 4.9 6.9 13.8 15.0 Note: 1. Material: S.P.C.C. 2. Thickness: 0.8mm 3. Treatment: Nickel plated 4. Unit: mm Specifications can be changed without notice! Make sure you are using the latest documentation, downloadable at www.tracopower.com www.tracopower.com Rev. February 23. 2015 Page 11 of 11