txl 035

Enclosed Power Supplies
TXL Series, 15­–1000 Watt
Features
◆ Compact metal case with
screw terminal block
◆ Dual and triple output models with
isolated outputs
◆ Universal input 85–264 VAC
◆ EMI/EMC compliance with EN 61000-6-3
and EN 61000-6-1
◆ Compliance to EN 61000-3-2 (PFC)
◆ Short circuit and overvoltage protection
◆ International safety approvals
◆ 3-year product warranty
The TRACOPOWER TXL series is a family of encased power supplies designed for
a wide range of cost critical applications. With a low profile metal case and screw
terminal block connection, they are easy to install in any equipment.
There are 64 models in this range with single, dual, and triple output voltages from
3.3 VDC to 48 VDC in 12 power ranges from 15 W to 1000 W. These power supplies have universal input and comply with European EMC standards and the Low
Voltage Directive (LVD).
Models with Single Output
Order Code
Case Type
Output Power max.
Output Voltage nom.
Output Current max.
TXL 015-3.3S
3.3 VDC
3.0 A
TXL 015-05S
5 VDC
3.0 A
TXL 015-12S
12 VDC
1.3 A
TXL 015-15S
B
15 Watt
15 VDC
1.0 A
TXL 015-24S
24 VDC
0.63 A
TXL 015-48S
48 VDC
0.32 A
TXL 025-3.3S
3.3 VDC
6.0 A
TXL 025-05S
5 VDC
5.0 A
12 VDC
2.1 A
15 VDC
1.7 A
TXL 025-24S
24 VDC
1.1 A
TXL 025-48S
48 VDC
0.57 A
TXL 035-3.3S
3.3 VDC
9.0 A
TXL 035-05S
5 VDC
7.0 A
TXL 035-12S
12 VDC
3.0 A
15 VDC
2.4 A
24 VDC
1.5 A
TXL 035-48S
48 VDC
0.8 A
TXL 050-05S
5 VDC
10.0 A
TXL 060-12S
12 VDC
5.0 A
15 VDC
4.0 A
24 VDC
2.5 A
TXL 025-12S
TXL 025-15S
C
35 Watt
TXL 035-15S
TXL 035-24S
TXL 060-15S
TXL 060-24S
http://www.tracopower.com
25 Watt
D
50 / 60 Watt
Page 1 of 11
Enclosed Power Supplies
TXL Series
15–1000 Watt
Models with Single Output
Order Code
Case Type
TXL 060-3.3S
TXL 060-05S
TXL 070-12S
TXL 070-15S
TXL 070-24S
TXL 070-48S
TXL 100-3.3S
TXL 100-05S
TXL 100-12S
TXL 100-15S
TXL 100-24S
TXL 100-48S
TXL 150-05S
TXL 150-12S
TXL 150-24S
TXL 150-48S
TXL 230-12S*
TXL 230-24S*
TXL 230-48S*
TXL 350-24S*
TXL 350-48S*
TXL 750-24S*
TXL 750-48S*
TXL 1000-24S*
TXL 1000-48S*
Output Power max.
60 / 70 Watt
E
J
100 Watt
L
150 Watt
N
230 Watt
O
350 Watt
P
750 Watt
Q
1000 Watt
Output Voltage nom.
3.3 VDC
5 VDC
12 VDC
15 VDC
24 VDC
48 VDC
3.3 VDC
5 VDC
12 VDC
15 VDC
24 VDC
48 VDC
5 VDC
12 VDC
24 VDC
48 VDC
12 VDC
24 VDC
48 VDC
24 VDC
48 VDC
24 VDC
48 VDC
24 VDC
48 VDC
Output Current max.
15.0 A
12.0 A
6.0 A
4.8 A
3.0 A
1.5 A
23.0 A
20.0 A
8.5 A
7.0 A
4.3 A
2.3 A
30.0 A
12.5 A
6.3 A
3.2 A
19.2 A
9.6 A
4.8 A
14.7 A
7.5 A
31.3 A
15.8 A
40.0 A
21.0 A
* with internal fan (see dimensions)
Models with Multiple Output
Order Code
Case Type
TXL 035-0512D
TXL 035-0524D
TXL 035-1212D
TXL 035-1515D
TXL 060-0512DI
TXL 060-0524DI
TXL 060-0521TI
TXL 060-0522TI
TXL 060-0533TI
TXL 060-0534TI
TXL 100-0512DI
TXL 100-0524DI
TXL 100-0521TI
TXL 100-0522TI
TXL 100-0533TI
TXL 100-0534TI
Output Power
max.
D
35 Watt
E
60 Watt
J
100 Watt
* Output1
(Main Output)
+5 VDC/ 4.0 A
+5 VDC/ 4.0 A
+12 VDC/ 3.0 A
+15 VDC/ 2.4 A
5 VDC/ 8.0 A
5 VDC/ 6.0 A
5 VDC/ 8.0 A
5 VDC/ 7.0 A
5 VDC/ 7.0 A
5 VDC/ 6.0 A
5 VDC/ 12.0 A
5 VDC/ 12.0 A
5 VDC/ 12.0 A
5 VDC/ 12.0 A
5 VDC/ 12.0 A
5 VDC/ 12.0 A
* Output 2
+12 VDC/ 2.5 A
+24 VDC/ 1.3 A
–12 VDC/ 1.5 A
–15 VDC/ 1.5 A
12 VDC/ 4.0 A
24 VDC/ 2.2 A
12 VDC/ 3.5 A
12 VDC/ 3.5 A
15 VDC/ 3.0 A
12 VDC/ 1.5 A
12 VDC/ 7.0 A
24 VDC/ 3.5 A
12 VDC/ 5.0 A
12 VDC/ 5.0 A
15 VDC/ 4.0 A
12 VDC/ 4.0 A
* Output 3
5 VDC/ 1.0 A
12 VDC/ 1.0 A
15 VDC/ 1.0 A
24 VDC/ 1.2 A
5 VDC/ 1.5 A
12 VDC/ 1.5 A
15 VDC/ 1.5 A
24 VDC/ 2.0 A
* Total power must not exceed specified max. output power
http://www.tracopower.com
Page 2 of 11
Enclosed Power Supplies
TXL Series
15–1000 Watt
Input Specifications
Input voltage range
– nominal
– AC range (universal input)
– DC range 100 – 240 VAC
85 – 264 VAC for 15 to 350 Watt model
90 – 264 VAC for 750 & 1000 Watt models
120 – 375 VDC for 15 to 350 Watt model
127 – 375 VDC for 750 & 1000 Watt models
Input voltage frequency
47 – 63 Hz
Input current (at full load)
TXL 015/025 models:
TXL 035 models:
TXL 060/070 models:
TXL 100 models:
TXL 150 models:
TXL 230 models:
TXL 350 models:
TXL 750 models:
TXL 1000 models:
Vin = 115 VAC
0.50 A typ.
0.70 A typ.
1.00 A typ.
1.65 A typ.
2.10 A typ.
3.20 A typ.
3.30 A typ.
8.0 A typ.
11.0 A typ.
Vin = 230 VAC
0.22 A typ.
0.42 A typ.
0.60 A typ.
0.95 A typ.
1.10 A typ.
1.70 A typ.
1.70 A typ.
3.90 A typ
5.0 A typ.
Input current (at no load)
TXL 015/025 models:
TXL 035 models:
TXL 230/350 models:
TXL 750 models:
TXL 1000 models:
other models:
Vin = 115 VAC
10 mA typ.
50 mA typ.
115 mA typ.
210 mA typ.
330 mA typ.
100 mA typ.
Vin = 230 VAC
17 mA typ.
55 mA typ.
140 mA typ.
220 mA typ.
350 mA typ.
80 mA typ.
Recommended circuit breaker
up to 70 Watt models: 5 A
(characteristic C) or slow blow fuse
up to 350 Watt models: 10 A
TXL 750 & 1000 Watt models: 16 A
Output Specifications
Output voltage adjustment range ±10 %
– 35 Watt dual output models: range Vout 1–2
– other multi output models: Vout 1
Regulation
– Input variation
– Load variation (10–100%)
single output models:
multiple output models:
– Minimum load on main output of multiple output models:
(to provide the regulation on the auxilary outputs)
1 % max.
2 % max.
4 % max. for main output
6 % max. for output 2/3 (20–100 % load)
0.3 A for TXL 035
1.0 A for TXL 060
1.5 A for TXL 100
Ripple and noise (20 MHz bandwidth)
3.3 VDC output < 50 mV
Output 3 (on triple output models) < 1.5 % of Vout
all other output voltages < 1.0 % of Vout nom.
Output current limitation 105 % – 150 % of Iout max.
Overload protection mode Fold back, automatic recovery
Over voltage protection (only output 1) 115 % – 140 % of Vout nom.
(depending on model)
Capacitive load, max. www.tracopower.com/products/txl-capload.pdf
http://www.tracopower.com
Page 3 of 11
Enclosed Power Supplies
TXL Series
15–1000 Watt
General Specifications
Temperature ranges
– Operating –20°C to +70°C
– Load derating above +45°C 2 %/°K (2.5 %/°K for TXL 120/230/1000)
– Storage (non operating) –14°C to +85°C
Temperature coefficient 0.02 %/°C
Efficiency 70 – 84 % (depending on model)
Humidity (non condensing) 85 % rel max. (non condensing)
Switching frequency 50 kHz typ. (pulse width modulation)
Hold-up time 20 ms min.
Isolation voltage (60 sec.) – Input/Output
– Input/Case
– Output/Case
– Output/Output
60–100 Watt multiple output models:
35 Watt dual output models:
3‘000 VAC
1‘500 VAC
500 VAC
500 VAC (for all outputs of triple output models!)
outputs not isolated
Reliability /calculated MTBF (MIL-HDBK-217F, at +25°C typ., ground benign) >250’000 h Electromagnetic compatibility – Conducted input RI suppression
(EMC), Emissions
– Harmonic current emissions – Flicker
EN 55022, class B, FCC part 15, level B
IEC/EN 61000-3-2, class D (TXL 120/150/220)
IEC/EN 61000-3-2, class A (others)
IEC/EN 61000-3-3
Electromagnetic compatibility –
(EMC), Immunity –
–
–
–
–
–
IEC/EN 61000-4-2
IEC/EN 61000-4-3
IEC/EN 61000-4-4
IEC/EN 61000-4-5
IEC/EN 61000-4-6
IEC/EN 61000-4-8
IEC/EN 61000-4-11
Electrostatic discharge ESD
RF field immunity
Electrical fast transients/burst immunity
Surge
Conducted RF
Magnetic field
Voltage dip
4 kV / 8 kV
3 V/m
1 kV
1 kV / 2 kV
3 V/m
3 A/m
Safety standards UL 60950-1, IEC/EN 60950-1 2nd edition
Safety approvals
– UL/cUL – CB report TXL 015 models:
TXL 025 models:
TXL 035 models:
TXL 060/070 models:
TXL 100 models:
TXL 150 models:
TXL 230 models:
TXL 350 models:
TXL 750 models:
TXL 1000 models:
Environmental compliance
www.ul.com -> certifications -> File: e188913
www.tracopower.com/products/txl015-cb.pdf
www.tracopower.com/products/txl025-cb.pdf
www.tracopower.com/products/txl035-cb.pdf
www.tracopower.com/products/txl060-cb.pdf
www.tracopower.com/products/txl100-cb.pdf
www.tracopower.com/products/txl150-cb.pdf
www.tracopower.com/products/txl230-cb.pdf
www.tracopower.com/products/txl350-cb.pdf
www.tracopower.com/products/txl750-cb.pdf
www.tracopower.com/products/txl1000-cb.pdf
– Reach www.tracopower.com/overview/txl
– RoHS RoHS directive 2011/65/EU
Casing material
TXL 025/035 nickel plated steel (chassis & cover)
TXL 50/60/70/100aluminium (chassis), nickel plated steel (cover)
othersaluminium (chassis & cover)
All specifications valid at nominal input voltage, full load and +25°C after warm-up time unless otherwise stated.
http://www.tracopower.com
Page 4 of 11
Enclosed Power Supplies
TXL Series
15–1000 Watt
Case Dimensions
15.1
2x M3 THD
11.5
(0.45)
(2.44)
Top view
(0.99)
Vout
2 x M3 THD
(bottom)
25.25
L
N
+
Weight: 0.13 kg (4.6 oz)
39.1
14.7
(1.54)
(0.58)
51
62
(0.55 max.)
(2.01)
14 max.
39.1
(1.54)
(0.59)
Case B
28.0
(1.10)
65 (2.56)
14.5
2x M3 THD
(0.57)
Case C
3
(0.12)
(3.11)
L
N
2 x M3 THD
(bottom)
Top view
(1.0)
25.5
Vout
Weight: 0.19 kg (6.7 oz)
(2.01)
79
(0.55 max.)
51
14 max.
55
11
28.5
(2.17)
(0.43)
(1.12)
1
AC L
AC L
2
AC N
AC N
3
AC FG
AC FG
4
–Vout
Common
5
+Vout
Vout 1
6
No con.
Vout 2
74
10 max.
(0.28)
(3.90)
(0.39 max.)
0.3 kg (10 oz)
Max mounting screw penetration: 2.0 mm (0.08)
http://www.tracopower.com
99
7
(2.91)
1
2
3
4
5
6
2 x M3 THD
(bottom)
Top view
55
(2.17)
23.5
(0.93)
82 (3.23)
dual
45 (1.77)
single
(0.69)
2x M3 THD
Connection
Weight:
17.5
Case D
35
(1.38)
Page 5 of 11
Enclosed Power Supplies
TXL Series
15–1000 Watt
Case Dimensions
* Opposite polarity for TXL 060-0534TI
Weight:
10 max.
19
(0.75)
159
(6.26)
(0.39 max.)
1
2
3
4
5
6
7
8
9
1
2
3
4
5
6
7
Dual & Triple
output models
0.7 kg (25 oz)
118
(4.65)
19
AC L
AC N
AC FG
+Vout 3*
–Vout 3*
–Vout 1
+Vout 1
–Vout 2
+Vout 2
(0.75)
AC L
AC N
AC FG
No con.
No con
–Vout 1
+Vout 1
–Vout 2
+Vout 2
Top view
2 x M3 THD
(bottom)
Single
output
(3.74)
AC L
AC N
AC FG
–Vout
–Vout
+Vout
+Vout
–
–
95
Triple
(1.26)
Dual
10
18
Single
32
1
2
3
4
5
6
7
8
9
3 x M3 THD
(0.39)
Connection
(0.71)
Case E
78
57
38
(3.07)
(0.95)
(1.50)
Case J
AC L
AC N
AC FG
+Vout 3*
–Vout 3*
–Vout 1
+Vout 1
–Vout 2
+Vout 2
3 x M3 THD
158
20
(6.22)
(0.79)
19
AC L
AC N
AC FG
No con.
No con
–Vout 1
+Vout 1
–Vout 2
+Vout 2
(0.75)
AC L
AC N
AC FG
–Vout
–Vout
+Vout
+Vout
–
–
10
Triple
(0.39)
Dual
18
1
2
3
4
5
6
7
8
9
Single
(0.71)
Connection
* Opposite polarity for TXL 100-0534TI
10 max.
198
(7.80)
(0.39 max.)
Weight:
0.8 kg (28 oz)
Single
output
120
(4.72)
(3.74)
80
4 x M3 THD
(bottom)
95
(3.15)
Top view
(0.35)
Dual & Triple
output models
1
2
3
4
5
6
7
9
1
2
3
4
5
6
7
8
9
16.5
(0.45)
38
(1.50)
Max mounting screw penetration: 3.0 mm (0.12)
http://www.tracopower.com
Page 6 of 11
Enclosed Power Supplies
TXL Series
15–1000 Watt
Case Dimensions
6 x M4 THD
(0.49)
12.5
Case L
(2.20)
(0.98)
25
176.5
13 max.
56
(4.61)
RC Remote Control On/Off:
RC+/RC–: 0–0.7 V = On
3–10 V = Off.
RS Remote Sense
Can be open or connected to
the load under regard of polarity
(0.49)
117
12.5
21
(0.83)
Connector
11.5
(6.95)
(0.45)
198
(7.83)
(0.51 max.)
168
63
(2.48)
(6.61)
10
49.5
(1.95)
99
(3.9)
(3.11)
(2.56)
28
2 x M4 thread
(bottom)
65
Weight:
79
N
L
Top view
(1.10)
4 x M3 THD
(bottom)
10
Vout
V adj.
RC +
RS +
(0.39)
+
+
50
(1.97)
(0.39)
0.89 kg (31 oz)
4x TXL-CMB chassis mount brackets included in shipment
http://www.tracopower.com
Max mounting screw penetration: 3.0 mm (0.12)
Page 7 of 11
Enclosed Power Supplies
TXL Series
15–1000 Watt
(0.49)
6 x M4 THD
12.5
Case N
air flow
Outline Dimensions
11.5
176.5 (6.95)
12 max.
(0.98)
25
56 (2.20)
RC Remote Control On/Off:
RC+/RC–: 0–0.7 V = On
3–10 V = Off.
RS Remote Sense
Can be open or connected to
the load under regard of polarity
(0.49)
117 (4.61)
12.5
21
(0.83)
Connector
(0.45)
198 (7.8)
(0.47 max.)
V adj.
RC +
RS +
63
65
(2.56)
(2.48)
168 (6.61)
Weight:
(1.95)
28
N
L
(1.10)
2 x M4 THD
(bottom)
49.5
79 (3.11)
4 x M3 THD
(bottom)
45
10
+
+
(0.39)
Vout
99 (3.9)
Top View
(1.77)
10
(0.39)
0.88 kg (30 oz)
4x TXL-CMB chassis mount brackets included in shipment
12 max.
(1.16)
212
(0.98 ±0.03)
29.5
(5.91 ±0.03)
(0.49)
150 ±0.8
25 ±0.8
4 x M4 THD
12.5
air flow
Case O
Connector
RC Remote Control On/Off:
RC+/RC–: 0–0.7 V = On
3–10 V = Off.
RS Remote Sense
Can be open or connected to
the load under regard of polarity
(8.35)
(0.47 max.)
150
29.5
(5.91)
(1.16)
177.5 (6.99)
Weight:
1.05 kg (37 oz)
4x TXL-CMB chassis mount brackets included in shipment
http://www.tracopower.com
(3.44)
7
(4.53)
(1.97)
(1.28)
115
50
(0.39)
87.5
95
(3.74)
5 x M3 THD
(bottom)
10
N
L
54.5
4 x M4 THD
(bottom)
(2.15)
Vout
+
+
+
32.5
V adj.
RC +
RS +
50
(1.97 )
(0.28)
Max mounting screw penetration: 3.0 mm (0.12)
Page 8 of 11
Enclosed Power Supplies
TXL Series
15–1000 Watt
Outline Dimensions
Case P
Weight:
39
220
16
12.5
30
20
13
3.5 kg (123 oz)
25
210
40
30
29(bottom)
5
240(bottom)
6 (bottom)
40
125
145
S/N LABEL
6
TXL-CMB chassis mount bracket set
(4pcs) included in shipment. For dimensions see page 11.
15
220
20
8.5
40
63
air flow
34.5
CN3
210
6
6
113(bottom)
6 (bottom)
125
25
240
M O D E L L AB E L
16.5
113
30
5
16.5
275
Max mounting screw penetration: 3.0 mm (0.12)
CN3 pin consideration:
Pin 1: Current sharing to interconnect up to 3 units at parallel operation
Max power = units x 0.9, max deviation of voltage adjustment among units =100mV
Pin 2: Power Good Signal. TTL (3mA max.): 0 – 1 VDC = DC-Off, 3.3 – 5.6 VDC = DC-OK
Pin 3/4: Remote sense to be connected at load side under regard of polarity
Pin 5/6: Remote control input RC1& RC2
Pin 7/8 Auxillary output 12VDC/0.1A for remote control function
Using internal 12V auxiliary output
Remote On/Off function:
330Ω
RC1
Using external voltage
AUX
2KΩ
RC2
AUX
2KΩ
RC2
SW
12V
Connection cable with 500mm flyind leads
included!
Using internal 12V auxiliary output
AUX
2KΩ
Mating connector:
Housing: HRS DF11-08DS-2C
Crimp: HRS DF11-EP22SCB
RC1
12V
330Ω
SW
470Ω
330Ω
SW
GND
RC2
RC1
12V
5V
GND
GND
Parallel operation:
PSU
CN3
2
4
6
8
1
3
5
7
+v +v +v -v -v -v
PSU
CN3
2
4
6
8
1
3
5
7
PSU
CN3
+v +v +v -v -v -v
2
4
6
8
1
3
5
7
+v +v +v -v -v -v
RS-(PIN4)
+V
-V
RS+(PIN3)
LOAD
All specifications valid at nominal input voltage, full load and +25°C after warm-up time unless otherwise stated.
http://www.tracopower.com
Page 9 of 11
Enclosed Power Supplies
TXL Series
15–1000 Watt
Outline Dimensions
271.7 (10.70)
Case Q
17.3
(XXX)
(1.00)
40.6
25.4
7.8
(0.31)
3 x M4 THD
(0.81)
20.5
(XXX)
(both sides)
239.5 (9.43)
34.5
(1.36)
3 x M4 THD
(bottom)
−V
air flow
127.0 (5.00)
68.0 (2.68)
LED 1
CN15
CN14
PE
air flow
L
(0.73)
18.5
90.0 (3.54)
+V
Vadj
+
N
295.0 (11.61)
CN15
8
6
4
2
GND
ON/OFF
GND
−S
CS
DC_OK
5V_AUX
+S
Weight:
7
5
3
1
1.9 kg (67 oz)
Dimensions in [mm], () = Inch
Tolerances ±0.8 (±0.03)
Monting hole pich tolerances ±0.5 (±0.02)
Caution! Max mounting screw penetration: 3.0 mm (0.12)
TXL-CMB1 chassis mount bracket set (4pcs) included in shipment. For
dimensions see page 11.
CN14 Jumper on CN14 disables the Remote Off function
CN15 On/Off (pin 4 & 6): Contact closed = Power On, Contact open = Power Off
CN15 –S/+S (pin 1 & 2): Remote sense to be connected at load side under regard
of polarity
CN15 5V Aux (pin 3 & 8): Auxiliary output 5 VDC / 0.5 A
CN15 DC–OK (pin 5 & 8): TTL signal (2.2 mA max.): 0 – 1 VDC = DC–Off, 3.3 – 5.6 VDC = DC–OK
CN15 CS (pin 7): Current Sharing to interconnect up to 4 units at parallel operation
Max power = units x 0.9, max deviation of voltage adjustment among units =100mV
Parallel operation:
CN15
7
6
5
4
3
2
1
-S
CN15
PS1
8
CS
-V
+S
+V
7
6
5
4
3
2
1
-S
CN15
PS2
8
CS
-V
+V
+S
PS3
8
7
6
5
4
3
2
1
-S
CS
-V
+V
+S
-S
+S
Specifications can be changed any time without notice.
LOAD
Page 10 of 11
AC/DC Power Modules
TXL Series
15–1000 Watt
Chassi Mount Brackets
Order code: TXL-CMB
contains 4pcs brackets and screws
4x7
For series models:
•TXL 150; Case L
•TXL 230; Case N
•TXL 350; Case O
•TXL 750; Case P
R1
7.5
7.5
7.5
7.5
.5
R0
5.6
5.0
.0
5.0 10.0
The chassi mount brackets are bypacked along with the following models:
17.5
Ø4
12.5
.2
15.0
Order code: TXL-CMB1
contains 4pcs brackets and screws
15.0
16.8
4x7
5.0
For series models:
•TXL 1000; Case Q
.0
R1
6.9 6.9
2.8
7.8
11.2
12.7
.2
25.4
Ø4
5.6 8.6
4.9
6.9
13.8
15.0
Note:
1. Material: S.P.C.C.
2. Thickness: 0.8mm
3. Treatment: Nickel plated
4. Unit: mm
Specifications can be changed without notice! Make sure you are using the latest documentation, downloadable at www.tracopower.com