Industrial Power Supplies TCL Series, 24–120 Watt Features ◆ For Industrial, Office and Residential UL 60950 UL 508C Application ◆ Ultracompact Plastic Housing ◆ Connection by Cage Clamps Terminals or plugable Screw Terminals ◆ ◆ ◆ ◆ ◆ ◆ ◆ ◆ ◆ ◆ NEW◆ ◆ Reliable snap-on Mounting on DIN-Rails Adaptor for Wall Mounting Universal Input 85-264 VAC, 50/60 Hz Models with 5, 12, 24 and 48 VDC Output Output Voltage adjustable Power Good Signal Low Ripple and Noise Overload and Short-Circuit Protection Parallel Operation possible Worldwide Safety Approvals Redundancy Module 3 Year Product Warranty The TRACOPOWER TCL series are a family of DIN-Rail power supplies with an excellent price/performance ratio. With tightly regulated output voltage and high immunity against electrical disturbances on the mains they provide a reliable power source for sensitive loads in industrial process controls, machine tools and other equipment exposed to a difficult industrial environment. Compact size, light weight, easy snap-on mounting on DIN-rails and the choice of two connection terminal versions are other features of these power supplies. The TCL series complies with all mayor safety standards for Europe (EN60950, EN50178), North America (UL/ cUL60950, UL508C listed) or elsewhere in the world (with CB-Report IEC60950). Models Ordercode Input Voltage Output Power *Output Voltage Output Current Range max. nom. max. 5.1 VDC 4.0 A 12 VDC 2.0 A TCL 024–124 24 VDC 1.0 A TCL 060–112 12 VDC 4.0 A Detachable Screw 24 VDC 2.5 A Terminal Block TCL 024-105 TCL 024-112 24 W TCL 060–124 60 W TCL 060–148 85 –264 VAC 48 VDC 1.25 A TCL 120–112 Universal Input 12 VDC 8.0 A TCL 120–124 50 / 60 Hz 24 VDC 5.0 A 24 VDC 1.0 A 12 VDC 4.0 A TCL 024–124C 120 W 24 W TCL 060–112C TCL 060–124C 60 W TCL 060–148C TCL 120–112C TCL 120–124C 120 W 24 VDC 2.5 A 48 VDC 1.25 A 12 VDC 8.0 A 24 VDC 5.0 A Connection Cage-Clamps *Output adjustable http://www.tracopower.com Page 1 of 5 Industrial Power Supplies TCL Series 24–120 Watt Input Specifications Input voltage range output derating at operation between 85...93VAC/85...130VDC: 85...264 VAC / 85...375 VDC 15% for TCL 060 & TCL 120 models 20% for TCL 024-112 & TCL 024-124 30% for TCL 024-105 Input frequency 47 – 63 Hz Harmonic limits EN610000-3-2 Class A Input current at full load (typ.) 115 VAC TCL 24 models: 0.35 A TCL 60 models: 1.2 A TCL 120 models: 2.0 A Recommended circuit breaker (characteristic C or slow blow fuse) 230 VAC 0.2 A 0.6 A 1.0 A 5.0 A Output Specifications Output voltage adj. range (pot.meter on frontpanel) 5.1 VDC model: 12 VDC models: 24 VDC models: 48 VDC models: 5.0 – 5.25 VDC 12 – 15 VDC (12 - 16 VDC for TCL 024-112) 24 – 28 VDC 48 – 56 VDC Output regulation (10 to 90% load variation) 2.5% (1% for TCL 60-112) Ripple and Noise (20MHz Bandwidth) < 50 mV pk-pk Electronic short circuit protection current limitation at 120 % typ (constant current, automatic recovery TCL 24 models: foldback, automatic recovery) Parallel operation output current characteristic suitable for parallel operation of max. 5 units Overvoltage protection, triggerpoint 5.1 VDC model: < 6.5 VDC 12 / 24 VDC models: < 40 VDC 48 VDC models: < 60 VDC Hold-up time 115 VAC min. 15 ms Power good signal (TCL 60 & TCL 120 only) trigger point 12 VDC models: >11V 24 VDC models: >22V 48 VDC models: >44V 230 VAC min. 125 ms output signal (reference to – Vout) 11.0 V ±1.0V / 60 mA max. 22.0 V ±2.0V / 30 mA max. 44.0 V ±4.0V / 15 mA max. General Specifications Temperature ranges – Operating – Storage (non operating) – 10 °C…+70 °C max. – 25 °C…+85 °C Temperature derating – at 187...264 VAC or 265...375 VDC operation – at 93...132 VAC or 130...187 VDC operation – at 85...130 VDC operation 1.7% /K above 50°C 1.1% /K above 40°C 1.3% /K above 30°C Humidity (non condensing) 95 % rel. H max. Temperature coefficient 0.02 % /K Switching frequency 55 – 180 kHz depending on load (frequency modulation) Efficiency 88% typ. Isolation according to IEC/EN 60950, UL 60950, UL 508, EN 50178, EN 60204, EN 61558-2-8 Reliability, calculated MTBF @ 25°C (according to IEC-1709) TCL 24 models: >2.68 Mio h TCL 60 models: >2.94 Mio h TCL 120 models: >1.62 Mio h All specifications valid at nominal input voltage, full load and +25°C after warm-up time unless otherwise stated. http://www.tracopower.com Page 2 of 5 Industrial Power Supplies TCL Series 24–120 Watt General Specifications Safety standards IEC 60950, EN 60950 (output SELV), UL 60950, UL 508, EN 50178, EN 60204, EN 61558-2-8. - NEC class 2 (TCL 60 models only) Safety approvals (TCL 24 models pending) UL/cUL 60950 recognized, File E181381 UL 508C listed, File E210002 CB-Report per IEC 60950 Electromagnetic compatibility (EMC), Emissions EN 61000-6-3 Electromagnetic compatibility (EMC), Immunity EN 61000-6-2 Safety class degree of protection class 1 Case protection IP 20 (IEC 60529) Enclosure material plastic FR2010-110C (UL 94V-0 rated) Mounting 35 mm DIN-rails as per EN 50022-35x15/7.5 (snap-on with self-locking spring) Adapter for Wall-/Chassi Mounting (included) Options output characteristic optimized for battery charging available on request TCL–REM240 Redundancy Module This module enables redundant operation of any two TCL models by decoupling the 2 power supplies. It can also be used to separate sensitive loads from the main power source. Models Order code Inputs Vin Max power per input Output voltage Output current max. Connection TCL–REM240 2 x 5...60 VDC 144 W Vin – 0.9 VDC 8A detachable screw terminal block Specifications Operating temperature – 10°C...+70°C max. (14°F...+158°F) derating above 40°C (104°F): 1.5%/K Electromagnetic compatibility in correspondence to connected units (no internal switching device) Dimensions same as model TCL 24 (see page 4) All specifications valid at nominal input voltage, full load and +25°C after warm-up time unless otherwise stated. http://www.tracopower.com Page 3 of 5 Industrial Power Supplies TCL Series 24–120 Watt Outline Dimensions mm (inches) TCL 24 and TCL-REM240 100.0 (3.94) OUTPUT 1 2 Output 1 +Vout 2 –Vout 75.0 (2.95) DC-ON LED Output voltage adjust 1 Innput 1 AC Ground 2 Neutral 3 Live 2 3 INPUT 2.2 (0.09) Weight: 140g (4.9 oz) 27 (1.06) TCL 60 100.0 (3.94) OUTPUT 1 2 3 4 5 75.0 (2.95) DC-ON LED Output voltage adjust 1 Output 1 +Vout 2 +Vout 3 –Vout 4 –Vout 5 Power Good Innput 1 AC Ground 2 Neutral 3 Live 2 3 INPUT 3.2 (0.13) Weight: 265g (9.4 oz) Tolerances: ±0.5mm (±0.02) 45 (1.77) All specifications valid at nominal input voltage, full load and +25°C after warm-up time unless otherwise stated. http://www.tracopower.com Page 4 of 5 Industrial Power Supplies TCL Series 24–120 Watt Outline Dimensions mm (inches) TCL 120 100.0 (3.94) OUTPUT 1 2 3 4 5 Output voltage adjust 1 75.0 (2.95) DC-ON LED Output 1 +Vout 2 +Vout 3 –Vout 4 –Vout 5 Power Good Innput 1 AC Ground 2 Neutral 3 Live 2 3 INPUT DIN rail mounting hooks 20mm (0.79) wide Weight: 440g (15.5 oz) 3.2 (0.13) Tolerances: ±0.5mm (±0.02) 85 (3.35) Wall Mounting Bracket Instead on a DIN-rail, the module can be easily mounted on a chassis or wall with help of a mounting bracket which is supplied as standard with each Power Supply Specifications can be changed without notice Rev. 07/05 Jenatschstrasse 1 · CH-8002 Zurich · Switzerland Tel. +41 43311 4511 · Fax +41 43311 4545 · [email protected] · www.tracopower.com Page 5 of 5