PDF Datasheet

DC/DC Converters
TES 2M Series, 2 Watt
CB
Features
◆ Supplementary and reinforced insulation
◆ I/O isolation 4000 VACrms rated for
Scheme
IEC 60950-1
IEC 60601-1
UL 60950-1
ES 60601-1
300 Vrms working voltage
◆ 2 x MOOP Medical safety according to
AAMI/ANSI ES 60601-1:2005(R) and
IEC/EN 60601-1 3rd edition
◆ Industrial safety to UL/IEC/EN 60950-1
◆ Ultracompact SMD-package
◆ Operating temp. range –25°C to +80°C
◆ Qualified for leadfree reflow solder
process
◆ Available in tape & reel package
◆ 3-year product warranty
The TES 2M series is range of compact 2W DC/DC-converters providing a high
I/O-isolation voltage of 4000 VAC. With a reinforced I/O-isolation system this product is an economical solution for many applications in instrumentation, industrial
controls, medical equipment and everywhere where supplementary- or reinforced
insulation is required.
These converters are qualified for high solder temperature profiles in leadfree solder processes. For automated SMD production lines the devices can be supplied
in tape & reel package. Full SMD-design with exclusive use of ceramic capacitors
ensure a very high reliability and a long product lifetime.
Models
Ordercode
Input voltage range
Output voltage
Output current max.
Efficiency typ.
TES 2-0511M
5 VDC
400 mA
66 %
TES 2-0512M
12 VDC
165 mA
66 %
TES 2-0513M
5.0 VDC ±10%
(nominal 05 VDC)
15 VDC
133 mA
66 %
±12 VDC
±83 mA
72 %
TES 2-0523M
±15 VDC
±66 mA
73 %
TES 2-1211M
5 VDC
400 mA
66 %
TES 2-0522M
TES 2-1212M
TES 2-1213M
TES 2-1222M
12.0 VDC ±10%
(nominal 12 VDC)
12 VDC
165 mA
66 %
15 VDC
133 mA
66 %
±12 VDC
±83 mA
74 %
TES 2-1223M
±15 VDC
±66 mA
75 %
TES 2-2411M
5 VDC
400 mA
66 %
TES 2-2412M
TES 2-2413M
TES 2-2422M
TES 2-2423M
http://www.tracopower.com
24 VDC ±10%
(nominal 24 VDC)
12 VDC
165 mA
66 %
15 VDC
133 mA
66 %
±12 VDC
±83 mA
74 %
±15 VDC
±66 mA
75 %
Page 1 of 3
DC/DC Converters
TES 2M Series
2 Watt
Input Specifications
Input current no load 5 Vin models: 60 mA typ.
12 Vin models: 30 mA typ.
24 Vin models: 15 mA typ.
Reverse voltage protection 0.3 A max.
Recommended input fuse (slow blow) 5 Vin models: 1.0 A
12 Vin models: 0.5 A
24 Vin models: 0.2 A
Surge voltage (1 sec. max.) 5 Vin models: 9 V max.
12 Vin models: 18 V max.
24 Vin models: 30 V max.
Input filter internal capacitors
Output Specifications
Voltage set accuracy ±4 %
Voltage balance (dual output models) 1 % max.
Regulation
– Input variation 1.2 % / 1 % change of Vin
– Load variation 20 – 100 % 10 % max.
12 % max. for 5 Vout models.
Ripple and noise (20 MHz Bandwidth) 150 mVp-p max.
Temperature coefficient ±0.02 %/K
Short circuit protection 0.5 sec. max.
Minimum load 2 % of rated max current.
Capacitive load
single output models: 330 µF max.
dual output models: 100 µF max. (each output)
General Specifications
Temperature ranges
– Operating –25°C to +80°C
– Storage –55°C to +125°C
– Case temperature +90°C max.
Derating 2.5 %/K above 60°C
Humidity (non condensing) 95 % rel. H max.
Reliability, calculated MTBF (MIL-HDBK-217F at +25°C, ground benign) >2.0 Mio h
Isolation voltage (50Hz, 60sec.) – Input/Output 4000 VACrms
Isolation test voltage (1 sec.) 6000 Vpk
Leakage current (at 240VAC, 60Hz) 2 µA max.
Isolation capacitance
– Input/Output 20 pF max. (at 100KHz, 1V)
Isolation resistance
– Input/Output >10 Gohm (at 500VDC)
Safety standards IEC/EN 60950-1, IEC/EN 60601-1 3rd Edition,
ANSI/AAMI ES60601-1 and CAN/CSA-C22.2 No. 60601-1, Medical Electrical Equipment Part 1: General Requirements for Basic Safety
and Essential Performance
Safety approvals www.tracopower.com/products/tes2m-cb60950.pdf
www.tracopower.com/products/tes2m-cb60601.pdf
www.ul.com/database File: e188913 - QQGQ2
www.ul.com/database File: e188913 - QQHM2
– CB test certificate according IEC 60950-1
– CB test certificate according IEC 60601-1
– UL online certification to UL 60950-1 (entry pending)
– UL online certification to ES 60601-1
Switching frequency 50 – 100 kHz (PFM)
Environmental compliance
– Reach www.tracopower.com/products/tes2m-reach.pdf
– RoHS directive 2011/65/EU
All specifications valid at nominal input voltage, full load and +25°C after warm-up time unless otherwise stated.
http://www.tracopower.com
Page 2 of 3
DC/DC Converters
TES 2M Series
2 Watt
Physical Specifications
Casing material plastic
Weight 3.8 g (0.13oz)
Lead-free reflow solder process as per J-STD-020D.01 (to find at:
www.jedec.org - free registration required)
Moisture sensivity level (MSL) level 2 as per J-STD-033B.01 (to find at:
www.jedec.org - free registration required)
Washing process www.tracopower.com/products/smd-wash.pdf
Packaging
www.tracopower.com/products/tes2m-pack.pdf
Application note: www.tracopower.com/products/tes2m-application.pdf
Outline Dimensions
9.0 (0.35)
0.25 (0.01)
24.0 (0.94)
1.0 (0.04)
0.15
9
top view
3.11 (0.12)
7
8
15.24 (0.60)
2.54 (0.10)
Pin
Single
Dual
1
–Vin (GND)
–Vin (GND)
7
No con.
No con.
8
No con.
Common
9
+Vout
+Vout
10
–Vout
–Vout
16
+Vin
+Vin
1.4 (0.055) min.
2.8
3.11 (0.12)
15.24 (0.60)
(0.11)
13.7 (0.54)
2.8
Solder Pad Dimension
(0.11)
1
Pin-Out
18.1 (0.71)
10
13.7 (0.54)
16
0 - 4°
2.54 (0.10)
Dimensions in [mm], () = Inch
Tolerances ±0.25 (±0.01)
Pin pitch tolerances ±0.05 (±0.002)
Specifications can be changed without notice! Make sure you are using the latest documentation, downloadable at www.tracopower.com
www.tracopower.com
Rev. December 06. 2013
Page 3 of 3