TRACOPOWER TES2

DC/DC Converters
TES 2M Series, 2 Watt
CB
Scheme
Features
◆ Ultracompact SMD-package
◆ I/O isolation 4000 VACrms
◆ Reinforced insulation rated for working
UL 60950-1
UL 60601-1
voltages up to 300 VAC
◆ Industrial & medical safety approval
◆ Operating temp. range –25 °C to +71 °C
◆ Qualified for leadfree reflow solder
process
◆ Available in tape & reel package
The TES 2M series is a new range of ultra-compact 2W DC/DC-converters providing a high I/O-isolation voltage of 4000 VAC. With a reinforced I/O-isolation
system this product is an economical solution for many applications in instrumentation, industrial controls, medical equipment and everywhere where supplementaryor reinforced insulation is required to meet requested safety standards.
With a new package design these converters are qualified for the higher solder
temperature profiles in leadfree solder processes. For automated SMD production
lines the devices can be supplied in tape & reel package. Full SMD-design with exclusive use of ceramic capacitors ensure a very high reliability and a long product
lifetime.
Models
Ordercode
Input voltage range
TES 2-0511M
Output voltage
Output current max.
Efficiency typ.
5 VDC
400 mA
66 %
12 VDC
165 mA
66 %
15 VDC
133 mA
66 %
± 12 VDC
± 83 mA
72 %
TES 2-0523M
± 15 VDC
± 66 mA
73 %
TES 2-1211M
5 VDC
400 mA
66 %
12 VDC
165 mA
66 %
15 VDC
133 mA
66 %
TES 2-0512M
TES 2-0513M
TES 2-0522M
TES 2-1212M
TES 2-1213M
TES 2-1222M
5.0 VDC ±10%
(nominal 05 VDC)
12.0 VDC ±10%
(nominal 12 VDC)
± 12 VDC
± 83 mA
74 %
TES 2-1223M
± 15 VDC
± 66 mA
75 %
TES 2-2411M
5 VDC
400 mA
66 %
TES 2-2412M
12 VDC
165 mA
66 %
15 VDC
133 mA
66 %
± 12 VDC
± 83 mA
74 %
± 15 VDC
± 66 mA
75 %
TES 2-2413M
TES 2-2422M
TES 2-2423M
http://www.tracopower.com
24 VDC ±10%
(nominal 24 VDC)
Page 1 of 3
DC/DC Converters
TES 2M Series
2 Watt
Input Specifications
Input current no load /full load 5 Vin models: 60 mA / 600 mA typ.
12 Vin models: 30 mA / 250 mA typ.
24 Vin models: 15 mA / 125 mA typ.
Reverse voltage protection 0.3 A max.
Recommended input fuse (slow blow)
5 Vin models: 1.0 A
12 Vin models: 0.5 A
24 Vin models: 0.2 A
Surge voltage (1 sec. max.) 5 Vin models: 9 V max.
12 Vin models: 18 V max.
24 Vin models: 30 V max.
Input filter internal capacitors
Output Specifications
Voltage set accuracy ± 4 %
Voltage balance (dual output models) 1 % max.
Regulation
– Input variation 1.2 % / 1 % change of Vin
– Load variation 20 – 100 % 10 % max.
12 % max. for 5 Vout models.
Ripple and noise (20 MHz Bandwidth) 150 mVpk-pk max.
Temperature coefficient ± 0.02 %/K
Short circuit protection 0.5 sec. max.
Minimum load 2 % of rated max current.
Capacitive load
single output models: 330 µF max.
dual output models: 100 µF max. (each output)
General Specifications
Temperature ranges
– Operating – 25 °C to + 75 °C
– Storage – 55 °C to + 125 °C
– Case + 110 °C max.
Derating 2.5 %/K above 60°C
Humidity (non condensing) 95 % rel. H max.
Reliability, calculated MTBF (MIL-HDBK-217F ground benign) > 2.0 Mio h @ 25°C
Isolation voltage (50Hz, 60sec) – Input/Output 4000 VACrms
Isolation test voltage (1 sec.) 6000 Vpk
Leakage current (at 240VAC, 60Hz) 2 µA max.
Isolation capacity
– Input/Output 20 pF max. (at 100KHz, 1V)
Isolation resistance
– Input/Output >10 Gohm (at 500VDC)
Switching frequency 50 – 100 kHz (PFM)
Safety standards IEC/EN 60950-1, UL 60950-1
CSA C22.2 No. 60950-1-03
IEC/EN 60601-1, UL 60601-1,
CSA C22.2 No. 601-1
Safety approvals
www.tracopower.com/products/thi2m-csa60601.pdf
www.tracopower.com/products/thi2m-csa60950.pdf
www.tracopower.com/products/thi2m-cb60601.pdf
www.tracopower.com/products/thi2m-cb60950.pdf
– CSA certificate
for medical electrical
for information technology
– CB test report
for medical electrical
for information technology
equipment
equipment
equipment
equipment
All specifications valid at nominal input voltage, full load and +25°C after warm-up time unless otherwise stated.
http://www.tracopower.com
Page 2 of 3
DC/DC Converters
TES 2M Series
2 Watt
General Specifications
Case material plastic
Weight 3.8 g (0.13oz)
Lead-free reflow solder process as per IPC J-STD-020D
Moisture sensitivity level (MSL) as per IPC J-STD-033B MSL report level 2
Outline Dimensions
0.25 (0.01)
9.0 (0.35)
24.0 (0.94)
0 - 4°
0.15
1.0 (0.04)
10
3.11 (0.12)
7
15.24 (0.60)
18.1 (0.71)
top view
1
Pin-Out
9
13.7 (0.54)
16
8
2.54 (0.10)
Pin
Single
Dual
1
–Vin (GND)
–Vin (GND)
7
No con.
No con.
8
No con.
Common
9
+Vout
+Vout
10
–Vout
–Vout
16
+Vin
+Vin
Solder Pad Dimensions
2.8
2.8
3.11 (0.12)
15.24 (0.60)
(0.11)
13.7 (0.54)
(0.11)
1.4 (0.055) min.
2.54 (0.10)
Dimensions in [mm], () = Inch
Tolerances ±0.25 (0.01)
Pin pitch tolerances ±0.05 (0.002)
Specifications can be changed any time without notice.
Rev. 08/08
Jenatschstrasse 1 · CH-8002 Zurich · Switzerland
Tel. +41 43 311 45 11 · Fax +41 43 311 45 45 · [email protected] · www.tracopower.com
Page 3 of 3