FPBS Data sheet

FPBS Data sheet
Sensing element/Absolute
Features
Applications
. Very small size( 5.8mm)
. Surface mount package
.
.
.
.
. Non-corrosive gas, Water or Sea water
Barometer, Relative altimeter
Weather forecast
Altitude compensation
Diving depth meter
Part number for ordering
FPBS - 04 A
Model
FPBS
Pressure type
A : Absolute pressure
Rated pressure
Pressure type
Absolute pressure
FPBS
Model
Package configuration
Surface mount package
Measurable pressure range(kPa.abs)
42.6 434.7
101.3 905.5
Part number for ordering
FPBS-04A
FPBS-82A
Specifications
Model/Rated pressure
04A
Recommended operating conditions
Pressure type
Rated pressure
82A
unit
905.5
8.2
101.3 905.5
kPa. abs
kg/cm2. abs
kPa. abs
Absolute pressure
434.7
3.4
42.6 434.7
Accuracy
Measurable pressure range
Pressure media
Non-corrosive gas, Water or Sea water
Excitation current(Constant)
0.15
Absolute maximum rating
Maximum load pressure
1961
2942
Maximum excitation current
3
Operating temperature
20 70
20 70
Storage temperature
30 85
Operating humidity
30 80 (No dew condensation)
Electric performances/characteristics (Excitation current I=0.15mA constant, Ambient temperature Ta=25 )
Full scale span voltage
2.5 7.0
5.0 9.0
Offset voltage
1.0 11.0 (at 62.1kPa. abs)
1.0 3.0 (at 101.3kPa. abs)
Bridge impedance
3000 4500
Mechanical response time
2 (For the reference)
Temperature sensitivity of offset (TSO)
5/10 40
5/5 35
Temperature coefficient of sensitivity (TCS)
2.5/10 40
2.5/5 35
Linearity
0.5 (NL1), 6.5 0 (NL2)
0.5
Note ;
It’s not available when pressure media always contact.
1
mADC
kPa. abs
mADC
RH
mV
mV
msec
FS
FS
FS
FPBS Data sheet
Sensing element/Absolute
Evaluating equations
. V(P,T)is defined as the output voltage at Pressure kPa. abs,
Temperature T.
. Full scale span voltage
(04A) : = SPAN[62.1 111.1kPa]=SPAN04(25)
=V(111.1,25) V(62.1,25)
(82A) : = SPAN[101.3 905.5kPa]=SPAN82(25)
=V(905.5,25) V(101.3,25)
. Offset voltage
(04A) : = V(62.1,25)
(82A) : = V(101.3,25)
. Temperature sensitivity of offset (TSO)
(04A) : = (V(62.1,40) V(62.1,10)/SPAN04(25) 100
(82A) : = (V(101.3,35) V(101.3,5)/SPAN82(25) 100
. Temperature coefficient of sensitivity(TCS)
(04A) : = (SPAN04MAX. SPAN04MIN.)/SPAN1(25) 100
(82A) : = (SPAN82MAX. SPAN82MIN.)/SPAN2(25) 100
SPAN MAX : = The value is bigger of SPAN04 or SPAN82.
SPAN MIN : = The value is smaller of SPAN04 or SPAN82.
. Linearity
(04A) : NL1= (V(86.6,25) (V(62.1,25)+V(111.1,25))/2)
/SPAN04(25) 100
NL2= (V(434.7,25) (333.4 SPAN04(25)/49.0+V
(101.3,25)))
/(434.7 SPAN04(25)/49.0) 100
(82A) : = (V(503.4,25) (V(101.3,25)+V(905.5,25))/2)
/SPAN82(25) 100
Example of output characteristics(04A)
Example of output characteristics(82A)
Excitation current : i=0.15mA Constant
Temperature : Ta=25
10.0
The best straight line between
62.1 and 111.1kPa abs
50.00
Output voltage (mV)
Output voltage (mV)
Excitation current : i=0.15mA Constant
Temperature : Ta=25
40.00
30.00
20.00
Sensor output line
10.00
0.00
3.23
101.3
199.4
The standard
atmospheric
pressure
297.4
395.5
8.0
6.0
4.0
Sensor output line
2.0
101.3
493.6
297.4
993.6
The standard
atmospheric
pressure
Pressure (kPa abs)
689.7
885.9
Pressure (kPa abs)
Outline dimensions
Unit : mm
FPBS
2
4.6
5.8
3
1
0.35
2.5
4
Recommended footprint for PCB
1
Pads
0.5
2-C0.2
2
1
3.2
3.2
1
Pressure detective part
unit : mm
FPBS Data sheet
Sensing element/Absolute
Connection diagram
Unit : mm
FPBS
OUTPUT(
1
Constant
current
source
INPUT(
)
4
)
Output voltage
2
OUTPUT(
3
INPUT(
)
Note ; Please read instruction “Notes” before using the sensor.
Fujikura reserves the right to change specifications without notice.
If you have any questions regarding technical issues or specifications, please contact us.
Sensor Engineering Department 5-1 Kiba 1-chome, Koto-ku, Tokyo 135-8512, Japan
Phone +81-(0)3-5606-1072 Fax. +81-(0)3-5606-1538
3
E-mail : [email protected]
)