FUJIKURA FAM

FPM,FAM Data sheet
Sensing element/Absolute
Features
Applications
. Dual-In-line-Package(DIP)or SMD, Easy to mount on PCB
. Barometric pressure measurable
. Industrial instrumentation
. Medical device
. Barometer, Altimeter
. Altitude compensation
Part number for ordering
FAM - 15P A S R
Terminal leads direction(See Outline Diagram)
No mark :
Model
FPM
FAM
Pressure type
A : Absolute
pressure
R:
Terminal leads configuration
No mark : DIP(FPM)
S : Surface mount package(FAM)
Rated pressure(PSI)
Pressure type
Absolute pressure
FPM
FAM
Dual-In-line-Package(DIP)
Surface mount package
Model
Package configuration
Measurable pressure range(kPa)
66.7 +66.7
FPM-15PA
Part number for ordering
FPM-15PAR
FAM-15PASR
Specifications
Model/Rated pressure
Recommended operating conditions
Pressure type
Rated pressure
15PA
Absolute pressure
34.66 168.0
0.3535 1.713
0 168.0
Non-corrosive gas
1.5
Accuray
Measurable pressure range
Pressure media
Excitation current (Constant)
Absolute maximum rating
Maximum load pressure
Twice of rated pressure
Maximum excitation current
3
Operating temperature
20 100
Storage temperature
40 120
Operating humidity
30 80 (No dew condensation)
Electric performances/characteristics (Excitation current I=1.5mA constant, Ambient temperature Ta=25 )
Full scale span voltage
80 160
Offset voltage
50 130 (at 101.3kPa . abs)
Bridge impedance
4000 6000
Mechanical response time
2 (For the reference)
Temperature sensitivity of offset (TSO)
3
Temperature coefficient of sensitivity (TCS)
2.5
Linearity
0.3
Pressure hystersis
0.2
1
Unit
kPa . abs
kg/cm2 . abs
kPa. abs
mADC
mADC
RH
mV
mV
msec
FS/0 50
FS/0 50
FS
FS
FPM,FAM Data sheet
Sensing element/Absolute
Outline dimensions
Unit (mm)
FPM (Absolute pressure)
8
5.5
12
Pressure port
2.85
5
4
1
2
3
3
R
14
4
5
6
3
2
1
15.24(600mil)
1.
5
6
C
5
5
0.
0.5
60
1.2
2.54 2.54
Labelled faceplate
Recommended footprint for PCB
6- 0.9(Diameter of through holes)
6- 1.8(Diameter of lands)
2.54 2.54
2.8
6.8
15.2
unit(mm)
Unit (mm)
0.25
FPM-R (Absolute pressure)
5
4
1
2
3
8
Pressure port
2.85
4
5
6
3
2
1
5
5
0.
C
15.24(600mil)
14
3
R
1.
5
6
5.5
max.15
12
Recommended footprint for PCB
2.54 2.54
6- 0.9(Diameter of through holes)
6- 1.8(Diameter of lands)
2.8
2.54 2.54
60
1.2
0.5
Labelled faceplate
6.8
15.2
2
unit(mm)
FPM,FAM Data sheet
Sensing element/Absolute
Outline dimensions
Unit (mm)
FAM
2.54 2.54
2
3
7
1
Pressure port
6
5
4
0.8
7
Index
X.
MA
6
5
4
Labelled faceplate
Recommended footprint for PCB
10.3
1.4
1.7
Land-pads
1
3
2
3
2.54 2.54
15
0.8
3.5
0.25
10 M
AX.
0.15
1
3
9.4
unit (mm)
FPM,FAM Data sheet
Sensing element/Absolute
Connection diagram
Unit (mm)
FPM (Absolute pressure)
i
1.5mA
5
Output voltage
R2
Constant
current
source
R1
6
4
1
R3
R4
6
2
VR0
1
Zero balancing trimmer (VR0) is available.
VR0 :200
Unit (mm)
FAM
i
1.5mA
2
Output voltage
R2
Constant
current
source
R1
1
3
6
R3
R4
5
1
VR0
6
Zero balancing trimmer (VR0) is available.
VR0 :200
Note ; Please read instruction “Notes” before using the sensor.
Fujikura reserves the right to change specifications without notice.
If you have any questions regarding technical issues or specifications, please contact us.
Sensor Engineering Department 5-1 Kiba 1-chome, Koto-ku, Tokyo 135-8512, Japan
Phone +81-(0)3-5606-1072 Fax. +81-(0)3-5606-1538
4
E-mail : [email protected]