HG4181 - Willow Technologies

HG4181
Automotive Subminiature PCB Power Relay
FEATURES
Miniaturized structure, light weight
Improved contact capacity
Big gap type available for heavy motor load switching
TYPICAL AUTOMOTIVE APPLICATIONS
Power antenna
Alarm/anti-theft system
Power window
Automatic mirror adjustment
Interval wiper
Automatic head rest adjustment
Slide roof control
CONTACT DATA
Form
Mechanical
1 Form A (H), 1 Form C (Z)
60A
20A
AgNi0.15, AgSnOInO
100 mΩ max. at 0.1A, 6VDC
16VDC
35A, 10 min; 25A, 1 hr.
0.1A, 12VDC
107 ops.
Electrical
105 ops.
Make
Break
Max. Switching Current
Material
Initial Contact Resistance
Max. Switching Voltage
Max. Continuous Current
Min. Load
Service Life
COIL DATA
Coil Voltage
Code
Nominal
Voltage
(VDC)
006
009
012
024
6
9
12
24
Resistance
(Ω) ±10%
Big Gap
45
100
180
720
Standard
60
135
240
960
Must Operate
Voltage max.
(VDC)
Must Release
Voltage min.
(VDC)
3.6
5.4
7.3
14.4
0.6
0.9
1.2
2.4
CHARACTERISTICS
Operate Time
Release Time
Insulation Resistance
Dielectric Strength
Shock Resistance
Vibration Resistance
Drop Resistance
Power Consumption
Ambient Temperature
Weight
10 ms. typical
5 ms. typical
100 MΩ, at 500 VDC, 50%RH
500 Vrms,1 min.
10 g,11ms.
DA 1.5 mm, 10 - 55 Hz
1 M height drop on concrete
Standard: 0.6W; Big Gap: 0.8W
-30ºC to 85ºC operating; -40ºC to 100ºC storage
6 g, approx.
ORDERING DESIGNATION
HG4181 /
Example:
Model
Coil Voltage Code
Contact Form
H: 1 Form A; D: 1 Form B; Z: 1 Form C; SH: 1 Form U
Version
1: Sealed; 2: Dust Cover
Contact Material
Nil: AgNi10; A: AgNi0.15; C: AgCdO; S: AgSnOInO
Contact Gap
Nil: Standard; G*: Big Gap
Note: Big contact gap is not available for 1 Form U (SH)
Last Updated 020905
012 -
H
1
C
G
HG4181
1/2
HG4181
REFERENCE CURVES
OVERALL DIMENSIONS, MOUNTING HOLES AND WIRING DIAGRAMS (mm)
Overall Dimensions
Wiring Diagrams (Bottom View)
Mounting Holes (Bottom View)
1 Form A (H)
1 Form C (Z) & 1 Form U (SH)
1 Form A (H)
1 Form C (Z)
1 Form U (SH)
NOTES
1.
2.
3.
4.
5.
All parameters, unless otherwise specified, are measured at ambient temperature 23ºC.
Maximum make current refers to inrush current of motor load.
Electrical life obtained at motor load of locked rotor at 20A, 14VDC with operating frequency of 6 ops/min.
Custom-made services available with operational quantity. Please let us know your special requirements.
Specifications subject to change without prior notice.
Willow Technologies Limited
Shawlands Court
Newchapel Road
Lingfield, Surrey
England, RH7 6BL
Tel: +44 (0) 1342 835234
Fax: +44 (0) 1342 834306
http://www.willow.co.uk
email: [email protected]
HG4181