YAS538 CSC-1U Overview

CURRENT SENSOR
ANALOG OUTPUT GMR CURRENT SENSOR
CSC-1U
Coreless & High Accuracy
High accuracy current sensor is realized by highly sensitive GMR
LINEARITY
RESPONSE
BANDWIDTH
CURRENT
CONSUMPTION
Configuration of current sensor can be simplified with this coreless design.
0.05%
1µSEC
400kHz
6mA
elements which are used in e-compass.
Key Features
A
Applications
Coreless magnetic balanced current sensor
Motor Controller : General Inverter, A/C, Electric Tool
Less temperature drifts (offset & sensitivity)
DC Electricity Controller : UPS, Power Conditioner
Ratiometric or fixed amplitude is selectable
Electricity Measurement : Power Meter, EMS, Power Conditioner
Adjustable sensitivity
Improving Power Factor : General Inverter, A/C, UPS
BLOCK DIAGRAM
PACKAGE
5.22
1.55
3.65
0.914
1.442
0.73
14.3
GMR
Bandgap
Reference
VREF
R
Primary current
R
VSS
VDD
OUT
Sensitivity
Calibration
–
+
Current
base
Ratiometric
Sensitivity
Calibration
Magnetic field:-Bx
GMR
GMR
GMR
Fuse
ROM
Test
Circuit
VREF
VREF
–
VREF
–
Busbar
YAS583
+
Primary current
Low Dropout
Regulator
+
Magnetic field:+Bx
4.53
1.27
0.38
3.81
0.381
PBAS538B-101-01-e
CURRENT SENSOR
ANALOG OUTPUT GMR CURRENT SENSOR
Coreless Design
Small & light current sensor can be realized by
coreless & simple design.
Conventional sensor
YAS538
High Accuracy
Highly accurate linearity is realized by magnetic
balanced operation of high sensitivity GMR
elements.
YAS538
Open Loop
VOUT
MEASURE
CORE
VOUT
MEASURE
IDEAL
IDEAL
IBUS
IBUS
Coreless design minimizes the number of components
Best in class linearity is realized
Small & light current sensor can be realized
Linearity:0.05%FS
Improvement in Temperature Drifts
Temperature drifts of offset and Sensitivity are
reduced by proprietary circuit design.
Offset (mV)
Low Current Consumption
Low current consumption is realized by
designing less dependency to the amount of
primary electric current.
Temperature
Sensivitity (%)
A
Temperature
Temperature drifts related error is reduced
Busbar electric current 0A : 6mA
Offset temperature drift : ±6.0mV (TBD)
Busbar electric current 50A : 16mA
Sensitivity temperature drift : ±1.0%
When busbar is designed in designated layout
Rated Input Magnetic Field
1.0 mT(max)
Frequency Characteristic
400 kHz
(typ)
Magnetic Field Sensitivity
2.0 V/mT(typ)
Response Time
1.0 μs
(typ)
Linearity
0.05 %FS(max)
Current Consumption
6 mA
(typ)
Semiconductor Div.
203 Matsunoki-jima, Iwata, Shizuoka 438-0192 Japan
http://www.yamaha.co.jp/english/product/lsi/
Customer Service
Head Quarter
TEL : +81-539-62-4918
Shanghai Office TEL : +86-21-8017-2699
Seoul Office
TEL : +82-2-3467-330
Taipei Office
TEL : +886-2-7741-8888
• The content is subject to change without notice.
• Unauthorized use of this document is prohibited.
• These introductory informations cannot be used for designs.
Check with us for technical ones.
• Brand and product names used are trademarks of their respective holders.
Created in June. 2015 Document Code
:PBAS538B-101-01-e