135 industrial relays of small dimensions

RUC
industrial relays of small dimensions
with adaptor (V)
135
• Power relays of general application • AC and DC coils • Mounting:
in sockets; 35 mm rail mount acc. to PN-EN 60715; on panel; PCB
• Versions: faston 187 (4,8 x 0,5 mm); faston 250 (6,3 x 0,8 mm) • 3 mm
contact gap (option - only in versions with normally open contacts) • Additional
features: K - test button; L - light indicator (LED) • Applications: control
of electromagnets; systems of heating, cooling, ventillation, air conditioning;
control with single-phase and three-phase motors; catering industry machines
and equipment; automation systems; etc.
• Recognitions, certifications, directives: RoHS,
with adaptor (H)
Contact data
Number and type of contacts
Contact material
Rated / max. switching voltage
Min. switching voltage
Rated load
AC
AC1
DC1
Min. switching current
Max. inrush current
Rated current
Max. breaking capacity
Min. breaking capacity
Contact resistance
Max. operating frequency
• at rated load
• no load
AC1
2 C/O, 3 C/O, 2 NO, 3 NO
2 NO, 3 NO with contact gap ≥ 3 mm
AgCdO, AgNi
400 V / 440 V
230 V / 250 V ❶
5 V AgNi, 10 V AgCdO
16 A / 250 V AC or 10 A / 400 V AC
16 A / 250 V AC ❶
16 A / 24 V DC
5 mA AgNi, 10 mA AgCdO
40 A
16 A
4 000 VA
0,3 W AgNi, 1 W AgCdO
≤ 100 mΩ
AC1
1 200 cycles/hour
12 000 cycles/hour
AC
DC
6 ... 240 V 50/60 Hz
6 ... 220 V
AC: ≥ 0,15 Un
see Tables 1, 2, 3, 4
2,8 VA 50 Hz
1,5 W
Coil data
Rated voltage
Must release voltage
Operating range of supply voltage
Rated power consumption
AC
DC
400 V 50 Hz ❶
DC: ≥
0,1 Un
2,5 VA 60 Hz
1,7 W with contact gap ≥ 3 mm
Insulation according to PN-EN 60664-1
Insulation rated voltage
Rated surge voltage
Overvoltage category
Insulation pollution degree
Dielectric strength • between coil and contacts
• contact clearance
• pole - pole
Contact - coil distance
• clearance
• creepage
400 V AC
4 000 V
1,2 / 50 µs
III
3
2 500 V AC type of insulation: basic
1 500 V AC type of clearance: micro-disconnection
2 500 V AC with contact gap ≥ 3 mm, type of clearance: full-disconnection
2 500 V AC type of insulation: basic
≥ 5 mm
≥ 8 mm
General data
Operating / release time (typical values)
Electrical life
• resistive AC1
• cos φ
Mechanical life (cycles)
Motor load according to UL 508
Dimensions (L x W x H)
Weight
Ambient temperature
Cover protection category
Shock / vibration resistance
Solder bath temperature
Soldering time
• storage
• operating
20 ms / 15 ms
≥ 105 10 A, 400 V AC
≥ 105 16 A, 250 V AC
see Fig. 2
≥ 107
2 C/O: 1/3 HP 120 V AC, single-phase motor 1/2 HP 240 V AC, single-phase motor
3 C/O: 1/3 HP 120 V AC, single-phase motor 1/2 HP 240 V AC, single-phase motor
3 C/O: 1/2 HP 240 V AC, three-phase motor
RUC faston 4,8 x 0,5 ❷
RUC faston 6,3 x 0,8 ❸
80 g ❹
85 g ❺
-40...+85 oC
AC: -40...+55 oC 3 C/O, 3 NO / 16 A (+70 oC 2 C/O, 2 NO / 16 A)
DC: -40...+55 oC 3 C/O, 3 NO / 16 A (+70 oC 3 C/O, 3 NO / 10 A; 2 C/O, 2 NO / 16 A)
IP 00
PN-EN 60529
10 g / 5 g 10...150 Hz
max. 270 oC
max. 5 s
The data in bold type pertain to the standard versions of the relays.
❶ For RUC faston 4,8 x 0,5 with GUC11 socket, max. switching voltages
and coil voltages of relays are limited to 250 V AC/DC.
❷ For plug-in sockets version: 36,1 x 38,6 x 45,5 mm. For version: with (V) adaptor:
58,75 x 38,6 x 45,9 mm; with (H) adaptor: 46,8 x 38,6 x 62,45 mm. For version with mounting flange: 66,3 x 38,6 x 36,1 mm. For PCB version:
36,1 x 38,6 x 52,5 mm. ❸ For version: with (V) adaptor: 62,4 x 38,6 x 45,9 mm; with (H) adaptor: 46,8 x 38,6 x 66,1 mm. For version with mounting
flange: 66,3 x 38,6 x 36,1 mm.
❹ Weight of plug-in sockets version and PCB version (RUC faston 4,8 x 0,5). ❺ Weight of version with (V) or (H)
adaptor, and version with mounting flange.
Export Sales Department Phone +48 68 47 90 832 • Marketing Department Phone +48 68 47 90 900
www.relpol.com.pl
RUC
industrial relays of small dimensions
136
Coil data - DC voltage version
Coil code
Table 1
Rated voltage
V DC
Coil resistance
±10% at 20°C
Ω
Coil operating range
V DC
min. (at 20°C)
max. (at 55°C)
1006
6
28
4,8
6,6
1012
12
110
9,6
13,2
1024
24
430
19,2
26,4
1042
42
1 340
33,6
46,2
1048
48
1 750
38,4
52,8
1060
60
2 700
48,0
66,0
1110
110
9 200
88,0
121,0
1120
120
11 000
96,0
132,0
1220
220
37 000
176,0
242,0
The data in bold type pertain to the standard versions of the relays.
Coil data - DC voltage version, reinforced
Coil code ❶
Rated voltage
V DC
Table 2
Coil resistance
±10% at 20°C
Ω
Coil operating range
V DC
min. (at 20°C)
max. (at 55°C)
W012
12
85
9,6
W024
24
345
19,2
13,2
26,4
W048
48
1 370
38,4
52,8
W110
110
7 300
88,0
121,0
W220
220
30 000
176,0
242,0
❶ For version with contact gap ≥ 3 mm.
Coil data - AC 50/60 Hz voltage version
Coil code
Rated voltage
V AC
Table 3
Coil resistance
±10% at 20°C
Ω
Coil operating range
V AC
min. (at 20°C)
max. (at 55°C)
5006
6
4,3
4,8
6,6
5012
12
18,5
9,6
13,2
5024
24
75,0
19,2
26,4
5115
115
1 840,0
92,0
126,5
5120
120
1 910,0
96,0
132,0
5220
220
6 980,0
176,0
242,0
5230
230
7 080,0
184,0
253,0
5240
240
7 760,0
192,0
264,0
Coil data - AC 50 Hz voltage version
Coil code
3400
www.relpol.com.pl
Table 4
Coil operating range
V AC
Rated voltage
V AC
Coil resistance
±10% at 20°C
Ω
min. (at 20°C)
max. (at 55°C)
400
21 500
320,0
440,0
Export Sales Department Phone +48 68 47 90 832 • Marketing Department Phone +48 68 47 90 900
RUC
industrial relays of small dimensions
137
AC1
2 C/O
2 NO
3 C/O
3 NO
Export Sales Department Phone +48 68 47 90 832 • Marketing Department Phone +48 68 47 90 900
www.relpol.com.pl
RUC
138
industrial relays of small dimensions
Mounting
Relays RUC are offered in versions: • standard, for screw
terminals plug-in sockets GUC11 ❶ with clip MBA,
35 mm rail mount acc. to PN-EN 60715 or on panel
mounting with two M3 screws • with mounting flange
in the wall of the cover, on panel mounting, flat insert
connectors - faston 187 (4,8 x 0,5 mm) or faston 250
(6,3 x 0,8 mm) • with vertical (V) or horizontal (H) adaptors
for direct mounting on 35 mm rail mount acc. to PN-EN
60715, flat insert connectors - faston 187 (4,8 x 0,5 mm)
or faston 250 (6,3 x 0,8 mm) • for direct PCB mounting ❻.
❻ Relays are not available with (V) or (H) adaptor, and
cover with mounting flange.
❶ For RUC faston 4,8 x 0,5 with GUC11 socket, max. switching voltages
and coil voltages of relays are limited to 250 V AC/DC.
www.relpol.com.pl
Export Sales Department Phone +48 68 47 90 832 • Marketing Department Phone +48 68 47 90 900
RUC
industrial relays of small dimensions
139
Ordering codes
Cover protection
category
Type
Contact
material
Number and type
of contacts
R U C —
Connection
mode
—
Coil code
—
Additional
features
—
Contact material
10 - AgCdO
20 - AgNi
see Tables 1, 2, 3, 4 page 136
Number and type of contacts
12 - 2 C/O
13 - 3 C/O
22 - 2 NO
23 - 3 NO
52 - 2 NO, contact gap ≥ 3 mm ❶
53 - 3 NO, contact gap ≥ 3 mm ❶
Cover protection category
24VH-
in cover, IP 00 version ❷
in cover with mounting flange, IP 00 version
in cover with vertical adaptor, IP 00 version
in cover with horizontal adaptor, IP 00 version
Connection mode
5 - for PCB
6 - for flat insert connectors - faston 187 (4,8 x 0,5 mm)
and plug-in sockets
A - for flat insert connectors - faston 250 (6,3 x 0,8 mm)
Additional features
without marks - without additional features
K
- test button without block function ❸
L
- light indicator (LED diode)
KL
- test button without block function + light indicator (LED diode) ❸
❶ For versions with reinforced DC coils: W012, W024, W048, W110, W220 and with AC coils.
❷ Only for version RUC faston 4,8 x 0,5.
❸ Additional features is not available in versions of relays with contact gap ≥ 3 mm.
Examples of ordering codes:
RUC-2053-26-W024
relay RUC, faston 187 (4,8 x 0,5 mm), contact material AgNi, with three normally open
contacts, with contact gap ≥ 3 mm, in cover IP 00, for plug-in sockets GUC11, voltage
version 24 V DC - reinforced coil
RUC-2013-V6-3400-KL
relay RUC, faston 187 (4,8 x 0,5 mm), contact material AgNi, with three changeover
contacts, in cover IP 00, with vertical adaptor (V), for flat insert connectors, voltage version
400 V AC 50 Hz, with test button without block function and light indicator (LED diode)
RUC-2052-HA-W220-L
relay RUC, faston 250 (6,3 x 0,8 mm), contact material AgNi, with two normally open
contacts, with contact gap ≥ 3 mm, in cover IP 00, with horizontal adaptor (H), for flat insert
connectors, voltage version 220 V DC - reinforced coil, with light indicator (LED diode)
RUC-1022-25-5024
relay RUC, contact material AgCdO, with two normally open contacts, in cover IP 00,
for PCB, voltage version 24 V AC 50/60 Hz
Export Sales Department Phone +48 68 47 90 832 • Marketing Department Phone +48 68 47 90 900
www.relpol.com.pl
Plug-in sockets and accessories
for relays RUC, RUC-M
34
24
14
32
22
12
35,5
26,5
11
25,5
6,1
A2
21
11
41
7,6
31
A1
35
82
Screw terminals
Maximum screw torgue: 0,7 Nm
35 mm rail mount acc. to PN-EN 60715
or on panel mounting
82 x 42,2 x 26,5 mm
Three poles
16 A, 250 V AC
8,3
For RUC faston 4,8x 0,5, RUC-M
Dimensions
41
Connection diagram
4,2
GUC11 ❾
11
Accessories
11
42,2
MBA
❾ For RUC faston 4,8 x 0,5 and RUC-M, with GUC11 socket, max. switching voltages and coil voltages of relays are limited to 250 V AC/DC.
GUC11
Screw terminals
plug-in socket
with RUC faston 4,8 x 0,5 mm
relay.
Export Sales Department Phone +48 68 47 90 832 • Marketing Department Phone +48 68 47 90 900
www.relpol.com.pl