RUC industrial relays of small dimensions with adaptor (V) 135 • Power relays of general application • AC and DC coils • Mounting: in sockets; 35 mm rail mount acc. to PN-EN 60715; on panel; PCB • Versions: faston 187 (4,8 x 0,5 mm); faston 250 (6,3 x 0,8 mm) • 3 mm contact gap (option - only in versions with normally open contacts) • Additional features: K - test button; L - light indicator (LED) • Applications: control of electromagnets; systems of heating, cooling, ventillation, air conditioning; control with single-phase and three-phase motors; catering industry machines and equipment; automation systems; etc. • Recognitions, certifications, directives: RoHS, with adaptor (H) Contact data Number and type of contacts Contact material Rated / max. switching voltage Min. switching voltage Rated load AC AC1 DC1 Min. switching current Max. inrush current Rated current Max. breaking capacity Min. breaking capacity Contact resistance Max. operating frequency • at rated load • no load AC1 2 C/O, 3 C/O, 2 NO, 3 NO 2 NO, 3 NO with contact gap ≥ 3 mm AgCdO, AgNi 400 V / 440 V 230 V / 250 V ❶ 5 V AgNi, 10 V AgCdO 16 A / 250 V AC or 10 A / 400 V AC 16 A / 250 V AC ❶ 16 A / 24 V DC 5 mA AgNi, 10 mA AgCdO 40 A 16 A 4 000 VA 0,3 W AgNi, 1 W AgCdO ≤ 100 mΩ AC1 1 200 cycles/hour 12 000 cycles/hour AC DC 6 ... 240 V 50/60 Hz 6 ... 220 V AC: ≥ 0,15 Un see Tables 1, 2, 3, 4 2,8 VA 50 Hz 1,5 W Coil data Rated voltage Must release voltage Operating range of supply voltage Rated power consumption AC DC 400 V 50 Hz ❶ DC: ≥ 0,1 Un 2,5 VA 60 Hz 1,7 W with contact gap ≥ 3 mm Insulation according to PN-EN 60664-1 Insulation rated voltage Rated surge voltage Overvoltage category Insulation pollution degree Dielectric strength • between coil and contacts • contact clearance • pole - pole Contact - coil distance • clearance • creepage 400 V AC 4 000 V 1,2 / 50 µs III 3 2 500 V AC type of insulation: basic 1 500 V AC type of clearance: micro-disconnection 2 500 V AC with contact gap ≥ 3 mm, type of clearance: full-disconnection 2 500 V AC type of insulation: basic ≥ 5 mm ≥ 8 mm General data Operating / release time (typical values) Electrical life • resistive AC1 • cos φ Mechanical life (cycles) Motor load according to UL 508 Dimensions (L x W x H) Weight Ambient temperature Cover protection category Shock / vibration resistance Solder bath temperature Soldering time • storage • operating 20 ms / 15 ms ≥ 105 10 A, 400 V AC ≥ 105 16 A, 250 V AC see Fig. 2 ≥ 107 2 C/O: 1/3 HP 120 V AC, single-phase motor 1/2 HP 240 V AC, single-phase motor 3 C/O: 1/3 HP 120 V AC, single-phase motor 1/2 HP 240 V AC, single-phase motor 3 C/O: 1/2 HP 240 V AC, three-phase motor RUC faston 4,8 x 0,5 ❷ RUC faston 6,3 x 0,8 ❸ 80 g ❹ 85 g ❺ -40...+85 oC AC: -40...+55 oC 3 C/O, 3 NO / 16 A (+70 oC 2 C/O, 2 NO / 16 A) DC: -40...+55 oC 3 C/O, 3 NO / 16 A (+70 oC 3 C/O, 3 NO / 10 A; 2 C/O, 2 NO / 16 A) IP 00 PN-EN 60529 10 g / 5 g 10...150 Hz max. 270 oC max. 5 s The data in bold type pertain to the standard versions of the relays. ❶ For RUC faston 4,8 x 0,5 with GUC11 socket, max. switching voltages and coil voltages of relays are limited to 250 V AC/DC. ❷ For plug-in sockets version: 36,1 x 38,6 x 45,5 mm. For version: with (V) adaptor: 58,75 x 38,6 x 45,9 mm; with (H) adaptor: 46,8 x 38,6 x 62,45 mm. For version with mounting flange: 66,3 x 38,6 x 36,1 mm. For PCB version: 36,1 x 38,6 x 52,5 mm. ❸ For version: with (V) adaptor: 62,4 x 38,6 x 45,9 mm; with (H) adaptor: 46,8 x 38,6 x 66,1 mm. For version with mounting flange: 66,3 x 38,6 x 36,1 mm. ❹ Weight of plug-in sockets version and PCB version (RUC faston 4,8 x 0,5). ❺ Weight of version with (V) or (H) adaptor, and version with mounting flange. Export Sales Department Phone +48 68 47 90 832 • Marketing Department Phone +48 68 47 90 900 www.relpol.com.pl RUC industrial relays of small dimensions 136 Coil data - DC voltage version Coil code Table 1 Rated voltage V DC Coil resistance ±10% at 20°C Ω Coil operating range V DC min. (at 20°C) max. (at 55°C) 1006 6 28 4,8 6,6 1012 12 110 9,6 13,2 1024 24 430 19,2 26,4 1042 42 1 340 33,6 46,2 1048 48 1 750 38,4 52,8 1060 60 2 700 48,0 66,0 1110 110 9 200 88,0 121,0 1120 120 11 000 96,0 132,0 1220 220 37 000 176,0 242,0 The data in bold type pertain to the standard versions of the relays. Coil data - DC voltage version, reinforced Coil code ❶ Rated voltage V DC Table 2 Coil resistance ±10% at 20°C Ω Coil operating range V DC min. (at 20°C) max. (at 55°C) W012 12 85 9,6 W024 24 345 19,2 13,2 26,4 W048 48 1 370 38,4 52,8 W110 110 7 300 88,0 121,0 W220 220 30 000 176,0 242,0 ❶ For version with contact gap ≥ 3 mm. Coil data - AC 50/60 Hz voltage version Coil code Rated voltage V AC Table 3 Coil resistance ±10% at 20°C Ω Coil operating range V AC min. (at 20°C) max. (at 55°C) 5006 6 4,3 4,8 6,6 5012 12 18,5 9,6 13,2 5024 24 75,0 19,2 26,4 5115 115 1 840,0 92,0 126,5 5120 120 1 910,0 96,0 132,0 5220 220 6 980,0 176,0 242,0 5230 230 7 080,0 184,0 253,0 5240 240 7 760,0 192,0 264,0 Coil data - AC 50 Hz voltage version Coil code 3400 www.relpol.com.pl Table 4 Coil operating range V AC Rated voltage V AC Coil resistance ±10% at 20°C Ω min. (at 20°C) max. (at 55°C) 400 21 500 320,0 440,0 Export Sales Department Phone +48 68 47 90 832 • Marketing Department Phone +48 68 47 90 900 RUC industrial relays of small dimensions 137 AC1 2 C/O 2 NO 3 C/O 3 NO Export Sales Department Phone +48 68 47 90 832 • Marketing Department Phone +48 68 47 90 900 www.relpol.com.pl RUC 138 industrial relays of small dimensions Mounting Relays RUC are offered in versions: • standard, for screw terminals plug-in sockets GUC11 ❶ with clip MBA, 35 mm rail mount acc. to PN-EN 60715 or on panel mounting with two M3 screws • with mounting flange in the wall of the cover, on panel mounting, flat insert connectors - faston 187 (4,8 x 0,5 mm) or faston 250 (6,3 x 0,8 mm) • with vertical (V) or horizontal (H) adaptors for direct mounting on 35 mm rail mount acc. to PN-EN 60715, flat insert connectors - faston 187 (4,8 x 0,5 mm) or faston 250 (6,3 x 0,8 mm) • for direct PCB mounting ❻. ❻ Relays are not available with (V) or (H) adaptor, and cover with mounting flange. ❶ For RUC faston 4,8 x 0,5 with GUC11 socket, max. switching voltages and coil voltages of relays are limited to 250 V AC/DC. www.relpol.com.pl Export Sales Department Phone +48 68 47 90 832 • Marketing Department Phone +48 68 47 90 900 RUC industrial relays of small dimensions 139 Ordering codes Cover protection category Type Contact material Number and type of contacts R U C — Connection mode — Coil code — Additional features — Contact material 10 - AgCdO 20 - AgNi see Tables 1, 2, 3, 4 page 136 Number and type of contacts 12 - 2 C/O 13 - 3 C/O 22 - 2 NO 23 - 3 NO 52 - 2 NO, contact gap ≥ 3 mm ❶ 53 - 3 NO, contact gap ≥ 3 mm ❶ Cover protection category 24VH- in cover, IP 00 version ❷ in cover with mounting flange, IP 00 version in cover with vertical adaptor, IP 00 version in cover with horizontal adaptor, IP 00 version Connection mode 5 - for PCB 6 - for flat insert connectors - faston 187 (4,8 x 0,5 mm) and plug-in sockets A - for flat insert connectors - faston 250 (6,3 x 0,8 mm) Additional features without marks - without additional features K - test button without block function ❸ L - light indicator (LED diode) KL - test button without block function + light indicator (LED diode) ❸ ❶ For versions with reinforced DC coils: W012, W024, W048, W110, W220 and with AC coils. ❷ Only for version RUC faston 4,8 x 0,5. ❸ Additional features is not available in versions of relays with contact gap ≥ 3 mm. Examples of ordering codes: RUC-2053-26-W024 relay RUC, faston 187 (4,8 x 0,5 mm), contact material AgNi, with three normally open contacts, with contact gap ≥ 3 mm, in cover IP 00, for plug-in sockets GUC11, voltage version 24 V DC - reinforced coil RUC-2013-V6-3400-KL relay RUC, faston 187 (4,8 x 0,5 mm), contact material AgNi, with three changeover contacts, in cover IP 00, with vertical adaptor (V), for flat insert connectors, voltage version 400 V AC 50 Hz, with test button without block function and light indicator (LED diode) RUC-2052-HA-W220-L relay RUC, faston 250 (6,3 x 0,8 mm), contact material AgNi, with two normally open contacts, with contact gap ≥ 3 mm, in cover IP 00, with horizontal adaptor (H), for flat insert connectors, voltage version 220 V DC - reinforced coil, with light indicator (LED diode) RUC-1022-25-5024 relay RUC, contact material AgCdO, with two normally open contacts, in cover IP 00, for PCB, voltage version 24 V AC 50/60 Hz Export Sales Department Phone +48 68 47 90 832 • Marketing Department Phone +48 68 47 90 900 www.relpol.com.pl Plug-in sockets and accessories for relays RUC, RUC-M 34 24 14 32 22 12 35,5 26,5 11 25,5 6,1 A2 21 11 41 7,6 31 A1 35 82 Screw terminals Maximum screw torgue: 0,7 Nm 35 mm rail mount acc. to PN-EN 60715 or on panel mounting 82 x 42,2 x 26,5 mm Three poles 16 A, 250 V AC 8,3 For RUC faston 4,8x 0,5, RUC-M Dimensions 41 Connection diagram 4,2 GUC11 ❾ 11 Accessories 11 42,2 MBA ❾ For RUC faston 4,8 x 0,5 and RUC-M, with GUC11 socket, max. switching voltages and coil voltages of relays are limited to 250 V AC/DC. GUC11 Screw terminals plug-in socket with RUC faston 4,8 x 0,5 mm relay. Export Sales Department Phone +48 68 47 90 832 • Marketing Department Phone +48 68 47 90 900 www.relpol.com.pl