RUC - Zettler Electronics

RUC
industrial relays of small dimensions
with adaptor (H)
Number and type of contacts
Contact material
Rated / max. switching voltage
AC
Min. switching voltage
Rated load AC1
DC1
Min. switching current
Max. inrush current
Rated current
Max. breaking capacity
AC1
Min. breaking capacity
Contact resistance
Max. operating frequency
• at rated load
AC1
• no load
2 CO, 3 CO, 2 NO, 3 NO
2 NO, 3 NO with contact gap  3 mm
AgCdO, AgNi
400 V / 440 V
230 V / 250 V ❶
5 V AgNi, 10 V AgCdO
16 A / 250 V AC or 10 A / 400 V AC 16 A / 250 V AC ❶
16 A / 24 V DC (see Fig. 3)
5 mA AgNi, 10 mA AgCdO
40 A
16 A
4 000 VA
0,3 W AgNi, 1 W AgCdO
 100 m
Rated voltage
AC
DC
Must release voltage
Operating range of supply voltage
Rated power consumption
AC
DC
6 ... 240 V 50/60 Hz
6 ... 220 V
AC:  0,15 Un see Tables 1, 2, 3, 4
2,8 VA 50 Hz
1,5 W
Insulation rated voltage
Rated surge voltage
Overvoltage category
Insulation pollution degree
Dielectric strength
contacts
Contact - coil distance
400 V AC
4 000 V 1,2 / 50 µs
III
2
2 500 V AC
type of insulation: basic
1 500 V AC type of clearance: micro-disconnection
2 500 V AC
with contact gap  3 mm, type of clearance: full-disconnection
2 500 V AC
type of insulation: basic
 5 mm 2 CO, 2 NO  4 mm 3 CO, 3 NO
 8 mm 2 CO, 2 NO  5 mm 3 CO, 3 NO
Coil data
Insulation according to PN-EN 60664-1
General data
• between coil and
• contact clearance
• pole - pole
• clearance
• creepage
Operating / release time (typical values)
Electrical life
• resistive AC1
• cos
Mechanical life (cycles)
Motor load according to UL 508
Dimensions (L x W x H)
Weight
Ambient temperature
Cover protection category
Shock / vibration resistance
Solder bath temperature
Soldering time
• storage
• operating
1 200 cykli/h
12 000 cykli/h
6 ... 400 V 50 Hz ❶
DC: 
0,1 Un
2,5 VA 60 Hz
1,7 W with contact gap  3 mm
20 ms / 15 ms
> 105 16 A, 250 V AC
> 105 10 A, 400 V AC
see Fig. 2
> 107
2 CO: 0,33 HP 120 V AC, single-phase motor 0,5 HP 240 V AC, single-phase motor
3 CO: 0,33 HP 120 V AC, single-phase motor 0,5 HP 240 V AC, single-phase motor
3 CO: 0,5 HP 240 V AC, three-phase motor
RUC faston 4,8 x 0,5 ❷
RUC faston 6,3 x 0,8 ❸
80 g ❹ 85 g ❺
-40...+85 oC
AC: -40...+55 oC 3 CO, 3 NO / 16 A(+70 oC 2 CO, 2 NO / 16 A)
DC: -40...+55 oC 3 CO, 3 NO / 16 A(+70oC3CO,3NO/10A;2CO,2NO/16A)
IP 00
PN-EN 60529
10 g / 5 g 10...150 Hz
max. 270 oC
max. 5 s
The data in bold type pertain to the standard versions of the relays.
❶ For RUC faston 4,8 x 0,5 with GUC11 socket, max. switching voltages
and coil voltages of relays are limited to 250 V AC / DC.
❷ For plug-in sockets version: 36,1 x 38,6 x 45,5 mm. For version: with (V) adaptor:
58,75 x 38,6 x 45,9 mm; with (H) adaptor: 46,8 x 38,6 x 62,45 mm. For version with mounting flange: 66,3 x 38,6 x 36,1 mm. For PCB version:
36,1 x 38,6 x 52,5 mm. ❸ For version: with (V) adaptor: 62,4 x 38,6 x 45,9 mm; with (H) adaptor: 46,8 x 38,6 x 66,1 mm. For version with mounting
flange: 66,3 x 38,6 x 36,1 mm. ❹ Weight of plug-in sockets version and PCB version (RUC faston 4,8 x 0,5). ❺ Weight of version with (V) or (H)
adaptor, and version with mounting flange.
Export Sales Department phone +48 68 47 90 832, 951 • e-mail: [email protected]
www.relpol.com.pl
28.01.2014
with adaptor (V)
Contact data
• Power relays of general application • AC and DC coils • Mounting:
in sockets; 35 mm rail mount acc. to PN-EN 60715; on panel; PCB
• Versions: faston 187 (4,8 x 0,5 mm); faston 250 (6,3 x 0,8 mm) • 3 mm contact gap (option - only in versions with normally open contacts) • Additional
features: K - test button; L - light indicator (LED) • Applications: control
of electromagnets; systems of heating, cooling, ventillation, air conditioning;
control with single-phase and three-phase motors; catering industry machines
and equipment; automation systems; photoelectric systems; etc.
• Recognitions, certifications, directives: RoHS,
1
RUC
industrial relays of small dimensions
Coil data - DC voltage version
Coil code
Table 1
Rated voltage
V DC
Coil resistance
at 20 °C

Acceptable
resistance
Coil operating range
V DC
min. (at 20 °C)
max. (at 55 °C)
1006
6
28
± 10%
4,8
6,6
1012
12
110
± 10%
9,6
13,2
1024
24
430
± 10%
19,2
26,4
1042
42
1 340
± 10%
33,6
46,2
1048
48
1 750
± 10%
38,4
52,8
1060
60
2 700
± 10%
48,0
66,0
1110
110
9 200
± 10%
88,0
121,0
1120
120
11 000
± 10%
96,0
132,0
1220
220
37 000
± 10%
176,0
242,0
The data in bold type pertain to the standard versions of the relays.
Coil data - DC voltage version, reinforced
Coil code ❻
Rated voltage
V DC
W012
12
W024
W048
Table 2
Coil resistance
at 20 °C

Acceptable
resistance
Coil operating range
V DC
min. (at 20 °C)
max. (at 55 °C)
85
± 10%
9,6
13,2
24
345
± 10%
19,2
26,4
48
1 370
± 10%
38,4
52,8
W110
110
7 300
± 10%
88,0
121,0
W220
220
30 000
± 10%
176,0
242,0
❻ For version with contact gap  3 mm.
Coil data - AC 50/60 Hz voltage version, basic
Rated voltage
V AC
Coil resistance
at 20 °C

Acceptable
resistance
Coil operating range
V AC
min. (at 20 °C)
max. (at 55 °C)
5006
6
4,3
± 10%
4,8
6,6
5012
12
18,5
± 10%
9,6
13,2
5024
24
75
± 10%
19,2
26,4
5115
115
1 840
± 10%
92,0
126,5
5120
120
1 910
± 10%
96,0
132,0
5220
220
6 980
± 10%
176,0
242,0
5230
230
7 080
± 10%
184,0
253,0
5240
240
7 760
± 10%
192,0
264,0
Coil data - AC 50 Hz voltage version, special
Coil code
Rated voltage
V AC
Table 4
Coil resistance
at 20 °C

Acceptable
resistance
Coil operating range
V AC
min. (at 20 °C)
max. (at 55 °C)
3006
6
4,8
± 15%
4,8
6,6
3012
12
20
± 15%
9,6
13,2
3024
24
72
± 15%
19,2
26,4
3115
115
2 100
± 15%
92,0
126,5
3120
120
2 300
± 15%
96,0
132,0
3220
220
7 000
± 15%
176,0
242,0
3230
230
7 900
± 15%
184,0
253,0
3240
240
8 300
± 15%
192,0
264,0
3400
400
21 500
± 10%
320,0
440,0
28.01.2014
Coil code
Table 3
2
Export Sales Department phone +48 68 47 90 832, 951 • e-mail: [email protected]
www.relpol.com.pl
RUC
industrial relays of small dimensions
Fig. 1
Electrical life reduction factor
at AC inductive load
Fig. 2
Reduction factor
Number of cycles
N
Electrical life at AC resistive load.
Switching frequency: 1 200 cycles/hour
Breaking capacity [kVA]
DC current [A]
Max. DC breaking capacity
A -resistive load DC1
B -inductive load L/R = 40 ms
DC voltage [V]
Fig. 3
Connection diagrams (pin side view)
2 CO
2 NO
3 CO
3 NO
Dimensions - RUC faston 4,8 x 0,5
- PCB version
28.01.2014
11
52,5
Dimensions - RUC faston 4,8 x 0,5
- plug-in version (standard)
Power factor
N - electrical life
at AC1
3
Export Sales Department phone +48 68 47 90 832, 951 • e-mail: [email protected]
www.relpol.com.pl
RUC
industrial relays of small dimensions
Dimensions - RUC faston 4,8 x 0,5
- version with vertical adaptor (V)
Dimensions - RUC faston 4,8 x 0,5
- version with horizontal adaptor (H)
9,8
46,8
12
1,6
34,8
8,5
35,5
9,8
9,8
6,1
12
4,9
55,3
34,8
1,6
Dimensions - RUC faston 6,3 x 0,8
- version with vertical adaptor (V)
Dimensions - RUC faston 6,3 x 0,8
- version with horizontal adaptor (H)
Dimensions - RUC faston 4,8 x 0,5 (faston 6,3 x 0,8)
- version with mounting flange in the wall of the cover
Mounting
4,8 x 0,5
* (6,3 x 0,8)
7,15 (10,8) *
66,3
60,7
* - dimensions RUC faston 6,3 x 0,8
Relays RUC are offered in versions: • standard, for
screw terminals plug-in sockets GUC11 ❶ with clip MBA,
35 mm rail mount acc. to PN-EN 60715 or on panel
mounting with two M3 screws • with mounting flange
in the wall of the cover, on panel mounting with two M4
screws, flat insert connectors - faston 187 (4,8 x 0,5 mm)
or faston 250 (6,3 x 0,8 mm) • with vertical (V) or horizontal (H) adaptors for direct mounting on 35 mm rail mount
acc. to PN-EN 60715, flat insert connectors - faston 187
(4,8 x 0,5 mm) or faston 250 (6,3 x 0,8 mm) • for direct
PCB mounting ❼.
❼ Relays unavailable with (V) or (H) adaptor, and cover
with mounting flange.
❶ For RUC faston 4,8 x 0,5 with GUC11 socket, max. switching voltages
and coil voltages of relays are limited to 250 V AC / DC.
Export Sales Department phone +48 68 47 90 832, 951 • e-mail: [email protected]
www.relpol.com.pl
28.01.2014
8,2
4
RUC
industrial relays of small dimensions
Ordering codes
Cover protection
category
Type
Contact
material
Number and type
of contacts
R U C —
Connection
mode
—
Coil code
—
Additional
features
—
Contact material
10 - AgCdO
20 - AgNi
see Tables 1, 2, 3, 4 page 2
Number and type of contacts
12 - 2 CO
13 - 3 CO
22 - 2 NO
23 - 3 NO
52 - 2 NO, contact gap  3 mm ❽
53 - 3 NO, contact gap  3 mm ❽
Cover protection category
2 - in cover, IP 00 version ❾
4 - in cover with mounting flange, IP 00 version
V - in cover with vertical adaptor, IP 00 version
H - in cover with horizontal adaptor, IP 00 version
Connection mode
5 - for PCB
6 - for flat insert connectors - faston 187 (4,8 x 0,5 mm)
and for plug-in sockets
A - for flat insert connectors - faston 250 (6,3 x 0,8 mm)
Additional features
without marks - without additional features
K
- test button without block function ❿
L
- light indicator (LED diode)
KL - test button without block function + light indicator (LED diode) ❿
❽For versions with reinforced DC coils: W012, W024, W048, W110, W220 and with AC coils.
❾For relays RUC: for plug-in sockets; for PCB.
❿Additional features is not available in versions of relays with contact gap  3 mm.
Examples of ordering codes:
relay RUC, faston 187 (4,8 x 0,5 mm), with contact gap  3 mm, for plug-in sockets
GUC11, three normally open contacts, contact material AgNi, reinforced coil voltage
24 V DC, in cover IP 00
RUC-2013-V6-3400-KL relay RUC, faston 187 (4,8 x 0,5 mm), for flat insert connectors, with vertical adaptor
(V), three changeover contacts, contact material AgNi, coil voltage 400 V AC 50 Hz,
with test button without block function and light indicator (LED diode), in cover IP 00
RUC-2052-HA-W220-Lrelay RUC, faston 250 (6,3 x 0,8 mm), for flat insert connectors, with contact gap
 3 mm, with horizontal adaptor (H), two normally open contacts, contact material
AgNi, reinforced coil voltage 220 V DC, with light indicator (LED diode), in cover IP 00
RUC-1022-25-5024relay RUC, for PCB, two normally open contacts, contact material AgCdO, coil voltage
24 V AC 50/60 Hz, in cover IP 00
28.01.2014
RUC-2053-26-W024 5
Export Sales Department phone +48 68 47 90 832, 951 • e-mail: [email protected]
www.relpol.com.pl
Plug-in sockets and accessories
GUC11 ❽
Connection diagram
Dimensions
For RUC faston 4,8 x0,5, RUC-M
Screw terminals
Max. tightening moment
for the terminal: 0,7 Nm
35 mm rail mount
acc. to PN-EN 60715
or on panel mounting
82 x 42,2 x 26,5 mm
Three poles
16 A, 250 V AC
Accessories
MBA
❽For RUC faston 4,8 x 0,5 and RUC-M, with GUC11 socket, max. switching voltages and coil voltages of relays are limited to 250 V AC / DC.
GUC11
PRECAUTIONS:
1. Ensure that the parameters of the product described in its specification provide a safety margin for the appropriate operation of the device or system and never use
the product in circumstances which exceed the parameters of the product. 2. Never touch any live parts of the device. 3. Ensure that the product has been connected
correctly. An incorrect connection may cause malfunction, excessive heating or risk of fire. 4. In case of any risk of any serious material loss or death or injuries
of humans or animals, the devices or systems shall be designed so to equip them with double safety system to guarantee their reliable operation.
28.01.2014
Screw terminals
plug-in sockets for
RUC faston 4,8x0,5,
RUC-M
6
Export Sales Department phone +48 68 47 90 832, 951 • e-mail: [email protected]