Datasheet

TLS series
electronic tilt switches
• Wide trigger angle of up to 180 Degrees
• Factory Programmable hysteresis on reset angle
• Up to 5 Second delay on trigger and reset angle.
• Relay output switching up to 5A at 250VAC
• Two independent trigger and reset angles
• RoHS Compliant
Specifications
Contact number & arrangement
Max. switching voltage
Min. breaking capacity
Rated load (resistive - cos φ=1)
2 x SPST-NO ( 2 x Form A), 2 x SPST-NC1 ( 2 x Form B1)
AC/DC 250VAC / 30VDC
W 50mW
AC1 5A/250VAC (Consult factory for higher currents)
DC1 5A/30VDC
Max. switching power
1250VA / 150W
1)
Supply voltage
NC function requires the tilt switch to be powered at all times.
AC/DC 5 - 18VDC, 17 - 35VDC, 12 - 24VAC (see Ordering Codes, Page 2)
Current consumption
<150mA (both output relays energized)
Trigger angle range
180° (+/- 90° from horizontal) depending on part number
Reset range (minimum)
0.5° less than trigger angle
Resolution
0.1°
Accuracy
0.5°
Time Delay (factory set)
Housing
Dimensions (approx.)
secs 0 to 5 seconds in 100 msec steps
Polycarbonate (UL94-HB)
L x W x H 5.71” (over mounting flange) x 2.56” x 2.17” (145 x 65 x 55mm)
Weight
0.38lb (172g)
Ambient temperature
-40 to 70°C
Sealing
IP65
Shock resistance
10g
Vibration resistance
1.5mm DA 10...55Hz
Wiring Information
Cable length
Cable colors
12 inches (approx. 305mm)
Red & Black 5 - 12V supply (AC or DC)
Yellow & Blue Switch output 1 (volt free contact)
Brown & Orange Switch output 2 (volt free contact) - where fitted.
Page 1 of 3 www.aecsensors.com
Ref: TLS Series 012913JHM
Sales Department Tel: (888) 847-6552
TLS series
electronic tilt switches
Fig. 1
Dimensions and mounting holes
0.65
( 2.171 )
( .256 )
( 2.559 )
1.69
All dimensions in inches.
Not to scale.
Ordering codes
Type
T
1st Trigger Angle 1st Reset Angle
L
S
-
-
-
-
2nd Trigger Angle 2nd Reset Angle
-
-
Axis1
L
W
1
See Fig 2 for explanation of axis
H
1st Trigger angle
1st Reset angle3
01 ~ 90
Switch function
0.5 ~ 89.5
2nd Trigger angle
2nd Reset angle3
C
-
2 x SPST-NO
01 ~ 90
D
-
2 x SPST-NC
NB: Actual angle is negative - refer to Fig 2 for more information
2
Normally closed contacts require power supplied to
switch at all times.
2
3
0.5 ~ 89.5
Minimum reset angle = 0.5 degrees less than trigger angle
Operating supply voltage
Time delay (on Trigger)
A
-
5 - 18VDC
NIL
B
-
17 - 35VDC
0.1 ~ 5 seconds (in 100msec steps)
C
-
12 - 24VAC
Time delay is the same for 1st and 2nd Trigger angles.
Page 2 of 3
www.aecsensors.com
Ref: TLS series 012913JHM
Sales Department Tel: (888) 847-6552
-
Time Delay
No time delay
TLS series
electronic tilt switches
Mounting Instructions
Fig. 2
H Axis
L Axis
W Axis
Switch mounted in horizontal plane
Switch mounted in vertical plane
The Tilt Switch should be mounted in the horizontal plane for L or W axis and in the vertical plane for H axis. The factory can preprogram an offset for when the Tilt Switch is required to be mounted at an angle.
The Tilt Switch may be mounted using the four corner holes (preferred) or the two key hole slots at each end of the unit. Do not drill
the box as this may damage the internal components and will compromise the sealing.
Please ensure sufficient space is left to allow for the cable. Undue stress on the cable should be avoided.
Wiring Information
The Tilt Switch has a six wire cable for connection. As standard, the unit is supplied with a 12” cable - other lengths can be supplied
(contact factory). The Tilt Switch is not fused internally and a suitable external fuse should be fitted.
Wire Color
Function
Red
+ve Supply (AC or DC)
Black
-ve Supply (AC or DC)
Yellow
Switch 1 Common
Blue
Switch 1 NO (NC)
Brown
Switch 2 Common
Orange
Switch 2 NO (NC)
The Tilt Switch will work with any supply voltage within the chosen voltage range. The
internal switches are factory programmed as either normally open or normally closed.
The normally closed function requires the Tilt Switch supply voltage to be present at
all times. Disconnecting the supply to the Tilt Switch will cause the normally closed
contact to open. If the normally closed function is selected, the contact will close immediately after the supply voltage is applied to the Tilt Switch. Switch outputs are “volt
free” and may be used for switching voltages up to 230VAC and a maximum current of
5A per switch. (Contact factory for special requirements).
Switch Function
SPST-NO:
The switch contacts are open when the Tilt Switch is in the at rest position. The switch contacts will close
(make) when the trigger angle setpoint is reached and open (break) again at the reset angle setpoint as the Tilt Switch returns to the
at rest position.
SPST-NC:
The switch contacts close (make) as soon as power is supplied to the Tilt Switch, with the Tilt Switch in the at
rest position. The switch contacts will open (break) when the trigger angle setpoint is reached and close again at the reset angle
setpoint as the Tilt Switch returns to the at rest position.
Specifications are subject to change without notice. E&OE.
Page 3 of 3
American Electronic Components Inc., 1101 Lafayette St. Elkhart, IN46516
www.aecsensors.com
Sales Department Tel: (888) 847-6552
Ref: TLS series 012913JHM