86 Series Timer Modules • Type 86.60 for use with 90.73 socket and 60.13 relay, or with 90.72 socket and 60.12 relay • Type 86.10 and 86.20 for use with 95.03 or 95.05 sockets and 40 or 44 series relays, or with 94.02 or 94.04 sockets and 55.32 and 55.34 relays • LED indication • Approvals (according to type): cULus TOOLING MACHINES INDUSTRIAL APPLIANCES INDUSTRIAL AUTOMATION 19 86 Series Timer Modules 86.20 86.10 MONO-FUNCTION TIMER MODULE TYPE 86.20 ON pulse (DI): see page 22 - LED indication: relay ON - 4 time scales: see page 23 - Ordering informationn: see page 23 MONO-FUNCTION TIMER MODULE TYPE 86.10 ON delay (AI): see page 22 - LED indication: relay ON - 4 time scales: see page 23 - Ordering informationn: see page 23 The 86.10 and 86.20 timer modules are for use with 95.03 - 95.05 and 94.02 - 94.04 sockets Type 95.03 and 95.05 sockets Type 94.02 and 94.04 sockets 27 27 61 17.5 60.9 17.5 25.9 17.5 17.5 78.6 76 26 32 94.02 94.04 35.5 Numbers in bold type are European standard EN50 005. Plain numbers are US standard. Socket and module together with 55 series relay 15.8 15.8 95.03 95.05 32 Socket and module together with 40, 44 series relay 60.9 COM 41 12 31 11 21 10 11 9 COM 44 8 14 5 NO 44 8 34 7 24 6 14 5 NO 42 4 12 1 NC 42 4 32 3 22 2 12 1 NC A2 14 A1 13 25.9 60.9 17.5 17.5 11 COM 21 11 COM 14 NO 24 14 NO 12 NC 22 12 NC A2 14 20 A1 13 94.02 COIL 94.04 COIL A2 A1 COIL 25.9 78.6 11 9 76 41 12 32 A2 A1 COIL 95.03 95.05 32 17.5 17.5 86 Series Timer Modules 86.60 ® C US MULTI-FUNCTION TIMER MODULE TYPE 86.60 module for use with 90.72 and 90.73 (VARITEC) sockets - Additional clamp-terminal for external START (B1) - LED indication: green = relay ON yellow = relay ON - Time scales: see page 23 - Ordering information: see page 23 The 86.60 timer module is for use with 90.72 - 90.73 sockets Type 90.73 socket = = 3.25 3.25 75 75 = = Type 90.72 socket 30 38 30 38 22.5 26 Numbers in bold type are European standard EN50 005. Plain numbers are US standard. Socket and module together with 60 series relay 73.5 NO NC NC NO NO 24 6 22 5 12 4 14 3 34 32 24 22 14 12 9 8 7 5 3 4 NC NO NC NO NC socket relay module A2 A2 21 11 A1 7 7 8 1 2 A2 A2 31 21 11 A1 10 10 11 6 1 2 coil coil coil com com coil coil com com com 6 coil 66 70 21 86 Series Timer Modules EMC SPECIFICATIONS TYPE OF TEST REFERENCE STANDARD 86.10/20 EN 61000-4-2 n.a. 4 kV 8 kV 8 KV ENV 50140 (IEC 1000-4-3) 10 V/m 10 V/m EN 61000-4-4 2 kV 2 kV EN 61000-4-5 — 2 kV — 1 kV ENV 50141 (IEC 1000-4-6) 10 V 10 V EN 61000-4-8 — — EN 55022 class B class B ELECTROSTATIC DISCHARGE - contact discharge - air discharge RADIO-FREQUENCY ELECTROMAGNETIC FIELD (80 ÷ 1000 MHz) FAST TRANSIENTS (burst) (5-50 ns, 5 kHz) on Supply terminals 86.60 SURGES (1.2/50 µs) on Supply terminals - common mode - differential mode RADIO-FREQUENCY COMMON MODE (0.15 ÷ 80 MHz) on Supply terminals POWER-FREQUENCY (50 Hz) RADIATED AND CONDUCTED EMISSION TIME SCALES Type 86.10 Type 86.20 1.5 ÷15 s OFF ON 6 ÷ 60 s 0.8 ÷ 8 min OFF OFF ON OFF ON 6 5 TIME 6 5 TIME 6.4 ÷ 64 min ON 6 5 TIME 6 5 TIME Type 86.60 15 ÷ 125 ms OFF ON 0.1 ÷ 1s OFF ON 6 5 4 TIME 1 ÷ 10s OFF ON OFF ON 6 5 4 TIME 6 5 4 TIME 0.1 ÷ 1s 1 ÷ 10s 1 ÷ 10 min 0.1 ÷ 1 min OFF ON OFF ON 6 5 4 TIME 0.1 ÷ 1 h 1 ÷ 10 h OFF ON 6 5 4 TIME 6 5 4 TIME 6 5 4 TIME 1 ÷ 10 min 0.1 ÷ 1 h 1 ÷ 10 h Type 86.60...3 15 ÷ 125 ms OFF ON OFF ON OFF ON OFF ON 6 5 4 TIME 6 5 4 TIME 6 5 4 TIME 0.1 ÷ 1 min OFF ON OFF ON 6 5 4 TIME 6 5 4 TIME TECHNICAL DATA Type 86.10 Type 86.20 TYPE 86.60 SUPPLY VOLTAGE (UN) (12 to 24) V AC/DC (50/60 Hz) RELAY OPERATING RANGE (0.8 to 1.1) UN DELAY SETTING 1.5s to 64 min (see time scales) REPEATABILITY ±1% SETTING ACCURACY - FULL RANGE ±5% AMBIENT TEMPERATURE (–0 to +50)°C RECOVERY TIME ≤150 ms SUPPLY VOLTAGE (UN) AC: (12 to 240) V (50/60 Hz) DC: (12 to 125)V OPERATING RANGE AC: (10.8 to 252) V RELAY OPERATING RANGE DC: (10.8 to 135) V (0.8 to 1.1) UN DELAY SETTING 15 ms to 10h (see time scales) REPEATABILITY AND SCALE TOLERANCE - FULL RANGE ±1% RESET TIME ≤ 120 ms MINIMUM START PULSE DURATION 20 ms AMBIENT TEMPERATURE (–20 to +50)°C CONTACT SPECIFICATIONS TYPES 86.10 and 86.20: see 40, 44 and 55 series TYPE 86.60: see types 60.12 and 60.13 22 OFF ON 6 5 4 TIME 6 5 4 TIME 86 Series Timer Modules DESCRIPTION OF THE FUNCTIONS TYPE 86.10 AND TYPE 86.20 The (C) indicated in the diagrams refers to the position of the NO contact. U = SUPPLY VOLTAGE Wiring diagram - internal start L/+ N/- U C = RELAY CONTACT (NO) A1 TYPE 86.10 (AI) ON delay. Apply power to timer. Contact transfers after preset time has elapsed. Reset occurs when power is removed. U C T A2 t<T TYPE 86.20 (DI) ON pulse. Apply power to timer. Contact transfers immediately. After preset time has elapsed, contact returns to original position. U C T t<T TYPE 86.60 The (C) indicated in the diagrams refers to the position of the NO contact. When the LED (C) is illuminated, the NO contacts are closed. S = START U = SUPPLY VOLTAGE C = RELAY CONTACT (NO) Wiring diagram-internal start L/+ A1 OFF ON N/- U B1 T FUNCTION A1 N/- A2 S 321 t<T U U OFF ON C L/+ START A2 U 321 Wiring diagramexternal start Conforming to EN 60204-1 FUNCTION C T T T T T (AI) ON delay. Apply power to timer. Contact transfers after preset time has elapsed. Reset occurs when power is removed. (BE) OFF delay: timing on START release (internal start). Power must be applied at all times to timer. On closure of normally open control Signal Switch, the output contact transfers and remains in that position. When the Signal Switch is reopened, the desired delay begins. After preset time has elapsed, the contact returns to the original position. U OFF ON U OFF ON C 321 T FUNCTION S 321 t<T FUNCTION C T (DI) ON pulse. Apply power to timer. Contact transfers immediately. After preset time has elapsed, contact returns to original position. U OFF ON OFF ON C 321 T FUNCTION T T T OFF ON 321 FUNCTION FUNCTION C T T T T T t<T S C T T T t<T (EE) OFF pulse: timing on START release. Power must be applied at all times to timer. On opening a normally open control Signal Switch, the output contact transfers. After the desired time has elapsed, the contact returns to the original position. OFF ON U T U 321 t<T (SW) Symmetrical recycler: pulse start. Apply power to timer. First transfer of contact occurs as soon as power is applied. The timer now cycles between ON and OFF as long as power is applied. The ratio is 1:1 (time off = time on). T (DE) ON pulse: timing on START pulse. Power must be applied at all times to timer. On momentary or maintained closure of a normally open control Signal Switch, the output contact transfers. After the desired time has elapsed, the contact returns to the original position. U 321 FUNCTION S C T T T T (SP) Symmetrical recycler: pause start. Apply power to timer. First transfer of contact occurs after preset time has elapsed. The timer now cycles between OFF and ON as long as power is applied. The ratio is 1:1 (time off = time on). (FE) ON pulse + OFF pulse: timing on Start pulse and on START release Power must be applied at all times to timer. On opening or closing of a normally open Signal Switch the output contact occurs. After the desired time has elapsed, the contact returns to the original position. 23 86 Series Timer Modules ORDERING INFORMATION Example: 86 series multi-function timer module, with (12 to 240) V AC and (12 to 115) V DC supply voltage. 8 6 Series 24 1 0 0 Supply version Type 1 = ON delay (AI) 0 = AC (50/60 Hz)/DC 2 = ON pulse (DI) 6 = Multi-function (AI, DI, SW, SP, BE, DE, EE, FE) 0 2 4 0 0 0 0 Supply version Supply voltage 0 = Standard (time scales until 10h) 12 ... 125 V DC 240 = 12 ... 240 V AC type 86.60 only 024 = 12 ... 24 V AC/DC 3 = Time scales until 30h type 86.60 only