Datasheet

SIP 6 Contacts
Relay data
General data
Diagrams
- PCB relay with forcibly guided contacts
- Protective separation between coil/control
contacts and output contacts (> 8mm) and
output contacts in one row (> 8mm).
- EN 50205, type A
- Contact mounting:
SIP512
Control contacts
1NO/1NC
Output contacts
4NO
SIP422
Control contacts
2NC
Output contacts
4NO
- Small external dimensions
- Mean coil power 1.3W
- Holding power 0.39W
- For Railway Applications: EN 50155
Circuit diagram (view on relay upper side)
Contact lifetime (output contacts)
32
0,3
12,5
0,4
25,4
6,5
3,75
2,1
25,4
5 8,5 5 6,5 5 6,5 5 6,5 5
1
3
14
3,75
6,5
12,5
Ø1,3
4,1 0,5
3
3,75
5 8,5 5 6,5 5 6,5 5 6,5 5
3,75
2,1
14
2,9
SIP512
[mm]
4,1
Control contacts
Contact material
AgSnO2+0.2μm Au
Rated switching capacity
250VAC 6A AC1 1’500VA
Electr. life AC1 (360 cycles/h) approx.100’000
Inrush current max.
15A for 20ms
Switching voltage range
5 to 250 VDC/VAC
Switching current range*
5mA to 6A
Switching capacity range* 0.06VA(W) to 1’500VA
Contact resistance (as delivered) <100mΩ/28 V/100mA
Output contacts
Contact material
AgSnO2
Rated switching capacity
250VAC (440VAC) 16A AC1 4’000VA
Electr. life AC1 (360 cycles/h) approx. 250’000
Inrush current max.
60A for 20ms
Switching voltage range
5 to 480 VDC/VAC
Switching current range*
10mA to 16A
Switching capacity range* 0.12VA(W) to 4’000VA
Contact resistance (as delivered)< 100mΩ / 28 V / 100mA
* Guide values
28
Drop-out voltage
at 20 °C
Nominal current
in mA
Resistance in
Ohm at 20 °C
Tolerance in %
6
12
18
24
48
60
110
220
4,2
> 0,6
> 1,2
8,4
12,6
> 1,8
> 2,4
16,8
33,6
> 4,8
> 6,0
42,0
77,0 > 11,0
154,0 > 22,0
218
109
72,5
54,5
27,2
11,8
6,8
5,9
27,5
110
248
440
1’760
2’750
9’250
37’000
± 10
± 10
± 10
± 10
± 10
± 10
± 13
± 15
Min. pick-up
voltage at 20°C
Nominal voltage
VDC
Standard coils for direct current
(other voltages on request)
ELESTA relays GmbH, Heuteilstrasse 18,
CH - 7310 Bad Ragaz, Switzerland
Basic insulation
Double or reinforced insulation
Mechanical life
> 10 x 106 operations
Switching frequency, mechanical
15Hz
Response time
typically 18ms
Drop-out time**
typically 5ms
Bounce time of NO contact
typically 8ms
Bounce time of NC contact
typically 12ms
Shock resistance 16ms
NO contact > 10g
NC contact 8g
Vibration resistance
NO contact > 10g
10-200Hz
NC contact 5g
Test voltage coil/control contacts 2’500Veff 1min
Test voltage
5’000Veff 1min
coil-control contacts/output contacts
Test voltage output contacts
as against each other
4’000Veff 1min
Test voltage contact open
1’500Veff 1min
Insulation resistance
1011 Ω
Creepage resistance
CTI 250
Weight
approx. 60g
Mounting position
any
Ambient temperature
-40°C to +70°C
Type of protection
RT II
Solder bath temperature
270°C/5s
Thermal resistance
40K/W
Temperature limit for coil
125°C
Pollution degree
2
Overvoltage category
III
Resistance to short circuiting control contacts
1’000A SCPD 6A gG (pre-fuse)
Resistance to short circuiting output contacts
1’000A SCPD 16A gG (pre-fuse)
No. of operations x 1000
Output
side
Control
side
SIP422
SIP512
DC 1: 24V
1000
DC 14: 24V
100
DC-13: 24V
10
5
1
10
16
Switching current (A)
Contact lifetime (output contacts)
10 000
No. of operations x 1000
20
84,6
10 000
1000
AC 1: 230V
AC 1: 400V
100
AC15: 230V
10
AC 3: 230V
AC 3: 400V
5
1
10
16
Switching current (A)
UL 508: A600/R150
Maximal contact load at AC 1 with 230V:
2 contacts each with 16A
3 contacts each with 12A
4 contacts each with 10A
Excitation voltage range
1
2,0
1,5
1,0
2
** without spark suppression
UB
Insulation terms
Coil to control contacts: Basic insulation
Coil/control contacts to output contacts:
Double or reinforced insulation > 8mm
All output contacts in one row:
Double or reinforced insulation > 8mm
Tests, regulations
Approvals
SEV, UL, cUL, TÜV
UL File E188953
Sec. 4
Insulation class IEC 60664-1
250VAC
Protection class II
VDE 0106
Fire protection requirements
UL 94 / V0
UN
0,5
0
0
20
40
60
80
100
Ambient temperature °C
1) Max. excitation voltage with contact load:
Control contacts <2A, output contacts <5A
2) Min. excitation voltage (guaranteed values)
without previous operation
No heat accumulation due to intrinsic heating
of other components.
Continuous duty 100%.
Ordering example
SI P 4 2 2 24VDC
Coil voltage
Soldering tags
Number of NC contacts
Number of NO contacts
Type designation
Phone: +41 (0)81 303 54 00
Fax:
+41 (0)81 303 54 01
E-Mail: [email protected]
Internet: http://www.elestarelays.com
We reserve the right to make technical alterations.