SIP 6 Series Circuit Diagram (view on relay upper side) 3,75 6,5 14 3,75 0,4 2,1 25,4 5 8,5 5 6,5 5 6,5 5 6,5 5 4,1 0,5 3 Ø 1,3 25,4 5 8,5 5 6,5 5 6,5 5 6,5 5 6,5 14 0,5 32 2,9 12,5 1 3 [mm] 4,1 Control Contact Contact material AgSnO2 + 0,2 µm Au Rated switching capacity 250 VAC 6 A AC1 1500 VA Electr. life AC 1(360 cycles / h) approx.100000 Inrush current max. 15 A for 20 ms Switching voltage range 5 to 250 VDC / VAC Switching current range* 5 mA to 6 A Switching capacity range* 60 mW to 1500 W(VA) Contact resistance (as delivered) ≤100 mΩ / 6 V / 100 mA Output Contact Contact material AgSnO2 Rated switching capacity 250 VAC (440 VAC) 16 A AC1 4000 VA Electr. life AC 1(360 cycles / h) approx.250000 Inrush current max. 60 A for 20 ms Switching voltage range 5 to 250 VDC (480 VAC) Switching current range* 10 mA to 16 A Switching capacity range* 120 mW to 4000 W(VA) Contact resistance (as delivered) ≤100 mΩ / 6 V / 100 mA *Guided values ≥0,6 ≥1,2 ≥1,8 ≥2,4 ≥4,8 ≥6,0 ≥11,0 ≥22,0 218,0 109,0 72,0 54,5 27,2 21,8 11,8 5,9 43 44 44 33 34 34 12 23 11 24 12 22 11 21 SIP 512 SIP 422 A2 A1 A2 - Basic insulation at 250 VAC - Air and creepage distance >4 mm - Test voltage 2500 V / 50 Hz / 1 min - Double or reinforced insulation at 250 VAC - Air and creepage distance >8 mm - Test voltage 4000 V / 50 Hz / 1 min - Double or reinforced insulation at 250 VAC - Air and creepage distance >10 mm - Test voltage 5000 V / 50 Hz / 1 min Test voltage contact open 1500 V / 50 Hz / 1 min Creepage resistance CTI 250 Pollution degree 2 Overvoltage category III Insulation resistance at Up 500 VDC >100 MΩ Additional Data Mechanical endurance Switching frequency, mechanical Response time (all NO closed) Drop-out time** (all NC closed) Bounce time of NO contact Bounce time of NC contact Shock resistance 16 ms 27,5 ± 10% 110 ± 10% 248 ± 10% 440 ± 10% 1760 ± 10% 2750 ± 10% 9250 ± 13% 37000 ± 15% >10 x 106 operations 15 Hz typically 18 ms typically 5 ms typically 8 ms typically 12 ms NO > 10g NC > 8g Vibration resistance 10-200 Hz NO > 10g 10-50 Hz NC > 5g 50-200 Hz NC > 3,5g Resistance to short circuiting control contacts 1000 A SCPD 6 A gG / gL (pre-fuse) Resistance to short circuiting output contacts 1000 A SCPD 16 A gG / gL (pre-fuse) Ambient temperature -40°C to +70°C Thermal resistance 40 K / W Temperature limit for coil 125°C Weight ca. 60 g Mounting position any Type of protection RT II Solder bath temperature 270°C / 5 s DC 1: 24V DC 14: 24V 100 10 DC 13: 24V 1 5 Switching Current (A) → 10 16 Contact Lifetime output contacts AC 10000 AC 3: 230V 1000 AC 1: 400V AC 3: 400V 100 AC 1: 230V AC 15: 230V 10 1 5 Switching Current (A) → UL 508: A600 / R150 Maximal contact load at AC 1 with 230 V: 2 contacts with 16 A each 3 contacts with 12 A each 4 contacts with 10 A each 10 16 Load Limit Curve with Direct Current 16 8 4 2 1 0,8 0,4 1 2 0,2 0,1 0 50 100 150 200 0 20 40 60 Ambient Temperature °C → 80 Voltage (VDC) → 1) Inductive load L/R 40 ms 2) Resistive load 250 Excitation Voltage Range 2,5 Approvals 2,0 UL File E188953 Insulation class IEC 60664-1 Protection class II Fire protection requirements Sec. 4 250 VAC VDE 0106 UL 94 / V0 1,5 1 1,0 2 0,5 UB UN 0 Options, Accessories none available Product Key ELESTA GmbH, Heuteilstrasse 18, Fon: CH - 7310 Bad Ragaz, Switzerland Fax: 1000 3,0 Tests, Regulations SIP 4 2 2 24VDC Operations x 1000 → 54 **without spark suppression Resistance in Ohm at 20 °C Nominal current in mA Min. pick-up voltage at 20 °C 4,2 8,4 12,6 16,8 33,6 42,0 77,0 154,0 Drop-out voltage at 20 °C Nominal voltage VDC Standard coils for direct current (other voltages on request) 6 12 18 24 48 60 110 220 53 54 10000 Operations x 1000 → 33 64 Contact Lifetime output contacts DC Current (A) → 43 63 64 Insulation Data 20 84,6 3,75 12,5 3,75 53 A1 Dimensions 2,1 63 Output Contacts - PCB Relay with forcibly guided contacts - Protective separation between coil/control contacts and output contacts (>8 mm) and output contacts in one row (>10 mm) - EN50205 type A - Contact mounting: SIP512 Control contacts 1 NO / 1 NC Output contacts 4 NO SIP422 Control contacts 2 NC Output contacts 4 NO - High switching power - Nominal coil power 1,3 W - Holding coil power 0,39 W - For railway application (EN50155) on request Control Contacts Relay Key Data Coil voltage Soldering tags Number of NC contacts Number of NO contacts Type designation +41 (0)81 303 54 00 +41 (0)81 303 54 01 100 1) Max. excitation voltage with contact load: control contacts ≤4 A, output contacts ≤12 A 2) Min. excitation voltage (guaranteed values) without previous operation © Copyright 11/2014