C63-10 - Teledyne Relays

C63-10 Series
1.0A, 60 Vdc Optically Isolated
Short-Circuit Protected
Part Number
C63-10
Description
1A, 60 Vdc short-circuit protected
solid-state relay for through-hole
mounting
SC63-10
1A, 60 Vdc short-circuit protected
solid-state relay for surface mount
ELECTRICAL SPECIFICATIONS
FEATURES/BENEFITS
(–40°C to +85°C ambient temperature unless otherwise specified)
INPUT (CONTROL) SPECIFICATIONS
Min
Max
Units
Input Current
8
20
mA
Input Voltage @ 10 mA
2
3
Vdc
Must Turn-On
8
mA
Must Turn-Off Current
100
µA
Must Turn-Off Voltage
0.8
Vdc
Reverse Polarity
–6
Vdc
• Short-circuit protected: Prevents damage to
system components, assemblies and system
wiring
• Optical isolation: Isolates control circuits from
load transients and eliminates ground loops and
signal ground noise
• Low off-state leakage
• Switches high currents: To 1.0 Amp
• High noise immunity: Control signals isolated
from switching noise
• High dielectric strength: For safety and for
protection of control and signal level circuits
OUTPUT (LOAD) SPECIFICATIONS
Min
Load Voltage Range
0
Output Current Rating (See Figure 4)
Max
Units
60
Vdc
1.0
A
Leakage Current at Rated Voltage
10
µA
Transient Blocking Voltage @25°C
100
Vdc
Output Capacitance @25Vdc (25°C)
600
pF
Output Voltage Drop @1A
0.55
Vdc
On Resistance
0.55
Ohm
Turn-On Time
2.0
ms
1.0
ms
Turn-Off Time
Trip Overload
© 2004 TELEDYNE RELAYS
(See Figure 7)
A
DESCRIPTION
The C63-10 solid-state relay utilizes a power FET
switch that is protected against short circuits and
overload currents. The short-circuit protection feature
provides protection when a short or overload occurs
while the relay is on as well as when the relay is
switched into an overload. In either case, the relay
will sense the overload condition and then block it
indefinitely until the overload is removed and the unit is
reset by cycling the input control. Using the C63-10 to
switch power sources and loads prevents damage to
system assemblies and system wiring. The power FET
output offers low “ON” resistance and can switch loads
in either the high or the low side of the power line. The
C63-10 is packaged in a 6-pin DIP package.
(800) 284-7007 • www.teledynerelays.com
C63 Page 1
2DSC63-10 Rev --
C63-10 Series
MECHANICAL SPECIFICATION
GENERAL SPECIFICATIONS
(+25°C ambient temperature unless otherwise specified)
ENVIRONMENTAL SPECIFICATION
Min
Max
Units
Operating Temperature
– 40
+85
°C
Storage Temperature
– 40
+100
°C
Junction Temperature @ 1A
+125
°C
Thermal Resistance θJA
125
°C/W
Dielectric Strength
1000
Vac
109
Ohm
Insulation Resistance
(@500 Vdc)
Input to Output Capacitance
5
Resistance to
Soldering Heat MIL STD 202, method 210
Solderability
MIL STD 202, method 208
Thermal Shock
MIL STD 202, method 107
pF
Figure 1
TYPICAL WIRING DIAGRAM
1
2
*
6
C63
**
Rs
3
5
4
LOAD
*
LOAD
*Shorted internally
**Series resistor required to limit input current to 20mA maximum
Figure 2
FUNCTIONAL BLOCK DIAGRAM
+IN (1)
INPUT
with
LEDs
Optical
Isolation
Detection
Circuit
Switching
Circuit
Output Switch
(MOSFET)
with Current
Sense
+OUT (6)
–OUT (4)
–IN (3)
Figure 3
C63 Page 2
SPECIFICATIONS ARE UNDER REVISION CONTROL
© 2004 TELEDYNE RELAYS
2DSC63-10 Rev --
C63-10 Series
CONTROL CURRENT VS. INPUT VOLTAGE
TYPICAL TURN-ON TIME VS. INPUT CURRENT
Figure 5
Figure 4
LOAD CURRENT VS. AMBIENT TEMPERATURE
Figure 6
NOTES:
TYPICAL OVERLOAD TRIP CURRENT VS. TIME
1. The C63-10 relay’s input current should be limited to
between 8 and 20mA. An external resistor whose value
=(VIN – 2.5 volts) ÷ 0.012 Amps is a good choice for
limiting input current.
2. Relay input transitions should be less than 1.0
millisecond.
3. Loads may be attached to either the positive or negative
output terminal.
4. Maximum load current ratings are with the relay in free
air and soldered to a printed circuit board.
5. Timing is measured from the input current transition to
the 10% or 90% points on the output voltage transition.
6. Overload conditions (including shorted loads) are
specified for load supply voltages to 60 Vdc maximum.
Figure 7
7. For through-hole-PCB-solder-attaching C63-10 series
relays, the wave-solder or solder pot operations are
limited to +260°C maximum for 10 seconds, maximum.
8. For surface-mount-solder-attaching SC63-10 series
relays, in IR heating or convection heating systems, the
component temperature is limited to +235°C maximum
for 10 seconds maximum.
© 2004 TELEDYNE RELAYS
(800) 284-7007 • www.teledynerelays.com
C63 Page 3
2DSC63-10 Rev --