Datasheet

Series C75
Optically Isolated 1.0A with Short-Circuit Protection & Trip Status
DC Solid-State Relay
FEATURES/BENEFITS
• Short Circuit Protected:
Prevents damage to system
components, assemblies and
system wiring
• Trip Status: Provides status
monitoring and feedback of the
protection state
• Optical Isolation: Isolates control
circuits from load transients
Eliminates ground loops and
signal ground noise
• Low Off-State Leakage: For high
off-state impedance
• Switches High Currents: To
1.0 Adc
• High Dielectric Strength:
For safety and for protection of
control and signal level circuits
DESCRIPTION
The C75-2S solid state relay utilizes
a power FET switch that is protected
against overload and short circuit
currents. Protection is provided
against turn-on into a short circuit,
shorts that occur while conducting
loads up to rated or for long term
overload currents above rated that
slowly overheat the relay. Once the
protection trips the relay off it will
remain off until reset by cycling the
input control. Using the C75-2S to
switch power loads can prevent
fires, damage to system assemblies
and system wiring. The power FET
output offers low “On” resistance and
can switch loads in either the high or
the low side of the power line. The
C75-2 is packaged in a 16 pin DIP,
with surface mount or through hole
mounting available. The C75-2SH
also provides an open collector trip
status feedback to the relay’s control
side for short circuit and thermal trip
monitoring.
H = Relay has an internal over
voltage suppressor for
inductive loads.
© 2004 TELEDYNE RELAYS
(800) 284-7007 • www.teledynerelays.com
C75 1
C75\112004\Q1
Series C75
ELECTRICAL CHARACTERISTICS
3.5
3.0
2.5
LOAD CURRENT (A)
TYPICAL
2.0
–40°C
1.5
TYPICAL
+25°C
+85°C
1.0
0.5
0
TRIP TIME (SECONDS)
TYPICAL TRIPP CURRENT VS. TIME
FIGURE 4
C75 2
SPECIFICATIONS ARE SUBJECT TO CHANGE WITHOUT NOTICE
© 2004 TELEDYNE RELAYS