Datasheet

Optical Liquid Level Sensors
D600D Series
* 1/2” SAE Threaded Body
* Low cost
* Compact size
* High reliability
* Wide range of commercial and
industrial applications.
Features:
Housing Style
D600
1/2” SAE-20 Thread (1)
Output Function
Digital (High or Low in Air) outputs
Repeatability
± 1mm
Hysteresis
1mm depending on liquid
Response time rising liquid
50µS
Response time falling liquid (ethanol)
< 1 second
Supply Voltage (Vs)
Supply Current
5 to 12Vdc
15mA nominal
Sink / Source Current
Temperature range: operating / (storage)
Housing Material
Cable Length
15mA
-25°C to +80°C / (–30° to +85°C)
Polysulphone UDEL 1700
200mm PTFE wires
Environmental
Thermal Testing
IP67 Rated
As per BS EN60068-2-33
Humidity
As per BS EN60068-2-30
Vibration
As per BS EN60068 Part S3: 1996
Mechanical Shock
Max. Pressure
As per BS EN60068-2-27 Part 2 Ea: 1987
7 bar
Order Codes:
High in Air Sensors: Output Voltage in Liquid < 1Vdc; Output Voltage in Air is within Vs - 0.5Vdc
3 Wire
4 Wire (2)
D600D3SH
D600D4SH
Low in Air Sensors: Output Voltage in Liquid is within Vs - 0.5VDC; Output Voltage in Air < 1Vdc
3 Wire
4 Wire (2)
1)
2)
D600D3LSH
D600D4LSH
“O” Ring supplied, unassembled.
In certain applications (when used in certain liquids or emulsions and in heavily condensing applications), it may be necessary to “tune” the sensor’s operation using a 4th wire
connected directly to the LED. This requires the installer to select a suitable current limiting
resistor—contact factory for details.
Drawing dimensions in millimetres
American Electronic Components Inc.,
1101 Lafayette Street, Elkhart, Indiana. USA
Tel: +1-574-295-6330 Fax: +1-574-293-8013
Email: [email protected]
http://www.aecsensors.com
© American Electronic Components Inc 2008
Specifications are subject to change without notice. E&OE.
D600D 290808