Features
• CMOS output
• Output frequencies to 160 MHz
• Tri-state output for board test and debug
• -10/70 or –40/85 °C operating temperature
• Product is compliant to RoHS directive
and fully compatible with lead free assembly
The VCB1 Crystal Oscillator
Applications
• SONET/SDH/DWDM
• Ethernet, Gigabit Ethernet
• Storage Area Network
• Digital Video
• Broadband Access
• Microprocessors/DSP/FPGA
Description
fo
Output
Buffer /
Disable
Vectron International 267 Lowell Rd, Suite 102, Hudson NH 03051
Vectron’s VCB1 Crystal Oscillator (XO) is a
quartz stabilized square wave generator with a
CMOS output. It operates off a 3.3 or 5.0 volt
supply.
rd
The VCB1 uses fundamental or 3 overtone
crystals, for output frequencies < 80MHz,
resulting in low jitter performance, typically 0.5ps
rms in the 12kHz to 20MHz band.
Tel: 1-88-VECTRON-1
e-mail: [email protected]
Performance Characteristics
Table 1. Electrical Performance, 5V option
Parameter
Symbol
Frequency
fO
1
Operating Supply Voltage
VDD
Absolute Maximum Supply Voltage
Supply Current, Output Enabled
IDD
0.032768 to 2.0 MHz
2.01 to 30 MHz
30.01 to 50 MHz
50.01 to 160.00 MHz
Output Logic Levels
2
Output Logic High
VOH
2
Output Logic Low
VOL
2
Output Rise/Fall Time
tR/tF
0.32768 to 2.00 MHz
2.01 to 20.00 MHz
20.01 to 160.00 MHz
3
Duty Cycle (ordering option)
SYM
Operating Temperature (ordering option)
Storage Temperature
4
Stability (ordering option)
5
Output Enable/Disable
Output Enabled
Output Disabled
Start-up time
Min
0.032768
4.5
-0.7
Typical
5.0
Maximum
160.000
5.5
7.0
Units
MHz
V
V
mA
10
15
40
50
0.9*VDD
V
V
ns
0.1*VDD
10
8
5
45/55
-10/70 or -40/85
%
°C
°C
ppm
V
-55
125
±20, ±25, ±32, ±50, ±100
4.0
0.8
10
ms
1. A 0.01uF and a 0.1uF capacitor should be located as close to the supply as possible (to ground) is recommended.
2. Figure 1 defines these parameters. Figure 2 illustrates the operating conditions under which these parameters are tested and
specified.
3. Symmetry is measured defined as On Time/Period.
4. Includes calibration tolerance, operating temperature, supply voltage variations, aging and shock and vibration (not under
operation).
5. Output will be enabled if enable/disable is left open.
tF
tR
IDD
V OH
4
50%
V DD
V OL
+
-
.1µF
.01µF
On Time
1
2
3
IC
VC
+
15pF
-
Period
Figure 1. Output Waveform
Figure 2. Typical Output Test Conditions (25±
±5°C)
Vectron International 267 Lowell Rd, Suite 102, Hudson NH 03051
Tel: 1-88-VECTRON-1
e-mail: [email protected]
VCB1 Data Sheet
Table 2. Electrical Performance, 3.3V option
Parameter
Symbol
Frequency
fO
1
Operating Supply Voltage
VDD
Absolute Maximum Operating Voltage
Supply Current, Output Enabled
IDD
0.032786 to 2.0 MHz
2.01 to 30 MHz
30.01 to 50 MHz
50.01 to 160 MHz
Output Logic Levels
2
Output Logic High
VOH
2
Output Logic Low
VOL
2
Output Rise/Fall Time
tR/tF
0.032768 to 2.00 MHz
2.01 to 20.00 MHz
20.01 to 160.00 MHz
3
Duty Cycle (ordering option)
SYM
Operating Temperature (ordering option)
Storage Temperature
4
Stability (ordering option)
5
Output Enable/Disable
Output Enabled
Output Disabled
Start-up time
Min
0.032768
2.97
-0.5
Typical
Maximum
160.000
3.63
5.0
3.3
Units
MHz
V
V
mA
8
10
20
35
0.9*VDD
V
V
ns
0.1*VDD
12
10
6
45/55 or 40/60
-10/70 or –40/85
%
°C
°C
ppm
V
-55
125
±20, ±25, ±32, ±50, ±100
2.0
0.5
10
ms
1. A 0.01uF and a 0.1uF capacitor should be located as close to the supply as possible (to ground) is recommended.
2. Figure 3 defines these parameters. Figure 4 illustrates the operating conditions under which these parameters are tested and
specified. For fo > 90MHz, rise and fall time is measured 20 to 80%.
3. Symmetry is measured defined as On Time/Period.
4. Includes calibration tolerance, operating temperature, supply voltage variations, aging and shock and vibration (not under
operation).
5. Output will be enabled if enable/disable is left open.
tF
tR
IDD
V OH
4
50%
V OL
V DD
+
-
.1µF
.01µF
On Time
1
+
15pF
-
Period
Vectron International 267 Lowell Rd, Suite 102, Hudson NH 03051
3
IC
VC
Figure 3. Output Waveform
2
Figure 4. Typical Output Test Conditions (25±
±5°C)
Tel: 1-88-VECTRON-1
e-mail [email protected]
VCB1 Data Sheet
Enable/Disable Functional Description
Under normal operation the Enable/Disable is left open or set to a logic high state. When the E/D is set to
a logic low, the oscillator stops and the output is in a high impedance state. This helps reduce power
consumption as well as facilitating board testing and troubleshooting.
Tri-state Functional Description
Under normal operation the tri-state is left open or set to a logic high state. When the tri-state is set to a
logic low, the oscillator remains active but the output buffer is in a high impedance state. This helps
facilitate board testing and troubleshooting.
Table 3. Outline Diagrams and Pin Out
Pin #
Symbol
Function
1
4
5
8
E/D or NC
GND
fO
VDD
Tri-state, Enable/Disable or NC
Electrical and Case Ground
Output Frequency
Supply Voltage
Figure 5. Package drawing
Vectron International 267 Lowell Rd, Suite 102, Hudson NH 03051
Tel: 1-88-VECTRON-1
e-mail [email protected]
VCB1 Data Sheet
Reliability
The VCB1 qualification tests have included:
Table 4. Environmental Compliance
Parameter
Mechanical Shock
Mechanical Vibration
Temperature Cycle
Gross and Fine Leak
Resistance to Solvents
MIL-STD-883
MIL-STD-883
MIL-STD-883
MIL-STD-883
MIL-STD-883
Conditions
Method 2022
Method 2007
Method 1010
Method 1014
Method 2015
Handling Precautions
Although ESD protection circuitry has been designed into the the VCB1, proper precautions should be
taken when handling and mounting. VI employs a Human Body Model and a Charged-Device Model
(CDM) for ESD susceptibility testing and design protection evaluation. ESD thresholds are dependent on
the circuit parameters used to define the model. Although no industry wide standard has been adopted for
the CDM, a standard HBM of resistance = 1.5kohms and capacitance = 100pF is widely used and
therefore can be used for comparison purposes.
Table 5. ESD Ratings
Model
Human Body Model
Charged Device Model
Minimum
1500
1000
Conditions
MIL-STD-883 Method 3115
JESD 22-C101
Suggested IR profile
Devices are built using lead free epoxy and can also be subjected to standard lead free IR reflow
conditions, Table 6 shows max temperatures and lower temperatures can also be used e.g. peak
temperature of 220C.
Table 6. Reflow Profile (IPC/JEDEC J-STD-020B)
Parameter
Symbol
Preheat Time
Ramp Up
o
Time Above 217 C
Time To Peak Temperature
Time At 260 oC (max)
Time At 240 °C (max)
Ramp Down
Value
tS
150 sec Min, 200 sec Max
R UP
tL
3 oC/sec Max
60 sec Min, 150 sec Max
480 sec Max
10 sec Max
60 sec Max
6 oC/sec Max
t AMB-P
tP
tp2
R DN
Vectron International 267 Lowell Rd, Suite 102, Hudson NH 03051
Tel: 1-88-VECTRON-1
e-mail [email protected]
VCB1 Data Sheet
Ordering Information:
VCB1 -
B
B -
3
125M00
Product Family
Output Frequency
Crystal Oscillator
In MHZ
½ Size DIP
Stability Options
Voltage Options
Electrical Options
A: ±100ppm, -10 to 70°C
A: +5.0 Vdc +/-10%, 15pF
3: Tri-state, 45/55% Duty
C: ±100ppm, -40 to 85°C
B: +3.3 Vdc +/-10%, 15pF
The following codes are not
B: ±50ppm, -10 to 70°C
C: +3.0 Vdc +/-10%, 15pF
recommended for new designs
D: ±50ppm, -40 to 85°C
E: +5.0 Vdc +/-10%, 50pF
0: No tri-state, 40/60% Duty
E: ±25ppm, -10 to 70°C
F: +3.3Vdc +/-10%, 50pF
1: Tri-state, 40/60% Duty
F: ±25ppm, -40 to 85°C
2: No tri-state, 45/55%Duty
G: ±20ppm, -10 to 70°C
5: Enable, 40/60% Duty
I: ±20ppm, -40 to 85°C
6: Enable, 45/55% Duty
Note: Not all combinations are available.
Tri-state with a 45/55% is the most common Electrical code and is recommended for most applications.
Devices will be shipped in Anti Static Tubes
For Additional Information, Please Contact:
USA: Vectron International • 267 Lowell Road, Suite 102, Hudson, NH 03051
• Tel: 1-88-VECTRON-1 • Fax: 1-888-FAX-VECTRON
EUROPE: Landstrasse, D-74924, Neckarbischofsheim, Germany •
Tel: 49 (0) 7268 8010 • Fax: 49 (0) 7268 801281
ASIA: Vectron International 68 Yin Cheng Road (C), 22nd Floor.,
One LuJiaZui, Pudong, Shanghai, China 200120
•Tel: 8621 6194 6886 • Fax: 8621 6194 6699
www.vectron.com
May16, 2014
Vectron International 267 Lowell Rd, Suite 102, Hudson NH 03051
Tel: 1-88-VECTRON-1
e-mail [email protected]
VCB1 Data Sheet
Revision History
Revision Date
Edited
Approved
May 16, 2014
VN
MB
Description
Added Stability Code “ I “ for ±20ppm -40/85C and updated new Vectron Logo.
Vectron International 267 Lowell Rd, Suite 102, Hudson NH 03051
Tel: 1-88-VECTRON-1
e-mail [email protected]