VCS3 series 1.8, 2.5, 3.3 volt CMOS Oscillator Features • Quick delivery • CMOS output • 3.2mm x 2.5mm x 1.2 mm • Output frequencies to 200.00 MHz • Tri-state output for board test and debug • -10/70 or –40/85°C operating temperature • Gold over nickel contact pads VCS3 Crystal Oscillator • Hermetically sealed ceramic SMD package • Product is compliant to RoHS directive and fully compatible with lead free assembly Applications • SONET/SDH/DWDM • Ethernet, Gigabit Ethernet • Storage Area Network • Digital Video • Broadband Access • Microprocessors/DSP/FPGA fo Output Buffer / Disable Vectron International 267 Lowell Road, Hudson NH 03051 Description Vectron’s VCS3 Crystal Oscillator (XO) is quartz stabilized square wave generator with a CMOS output, operating from a 1.8, 2.5 or 3.3 volt supply. The VCS3 utilized a high performance, low frequency quartz resonator followed by a custom ASIC to synthesize the output frequency. Tel: 1-88-VECTRON-1 e-mail: [email protected] Table 1. Electrical Performance, 3.3V option Parameter Symbol Frequency fO 1 Operating Supply Voltage VDD Absolute Maximum Operating Voltage Supply Current, Output Enabled IDD <30 MHz 30.01 to 75 MHz 75.01 to 133 MHz 133.01 to 200 MHz Supply Current, Output disabled IDD Output Logic Levels Output Logic High2 VOH Output Logic Low2 VOL Output Logic High Drive IOH Output Logic Low Drive IOL Output Rise/Fall Time2 , fo≤10MHz tR/tF fo>10MHz Duty Cycle3 SYM Operating Temperature (ordering option) Storage Temperature Stability4 (ordering option) Output Enable/Disable5 Output Enabled Output Disabled Start-up time Min 1.0 2.97 -0.5 Typical Maximum 200.000 3.63 5.0 3.3 10 15 20 25 15 0.9*VDD 0.1*VDD 8 8 3 2 55 45 -10/70 or –40/85 -55 125 ±25, ±50, ±100 0.7*VDD 0.3*VDD 2 Units MHz V V mA uA V V mA mA ns ns % °C °C ppm V ms 1. A 0.01uF and a 0.1uF capacitor should be located as close to the supply as possible (to ground). 2. Figure 1 defines these parameters. Figure 2 illustrates the operating conditions under which these parameters are tested and specified. 3. Symmetry is measured defined as On Time/Period. 4. Includes calibration tolerance, operating temperature, supply voltage variations, aging and shock and vibration (not under operation). 5. Output will be enabled if enable/disable is left open. tF tR IDD V OH 4 50% V DD V OL + - .1μF On Time .01μF 1 VC Period Figure 1. Output Waveform Vectron International 267 Lowell Rd, Hudson NH 03051 2 3 IC + 15pF - Figure 2. Typical Output Test Conditions (25±5°C) Tel: 1-88-VECTRON-1 e-mail: [email protected] VCS3 Data Sheet Table 2. Electrical Performance, 2.5V option Parameter Symbol Frequency fO Operating Supply Voltage1 VDD Absolute Maximum Voltage Supply Current, Output Enabled IDD < 30 MHz 30.01 to 75 MHz 75.01 to 166 MHz Supply Current, Out disabled IDD Output Logic Levels Output Logic High2 VOH Output Logic Low2 VOL Output Logic High Drive IOH Output Logic Low Drive IOL 2 Output Rise/Fall Time , fo≤10MHz tR/tF fo>10MHz Duty Cycle3 SYM Operating Temperature (ordering option) Storage Temperature Stability4 (ordering option) Output Enable/Disable5 Output Enabled Output Disabled Start-up time Min 1.0 2.25 -0.5 Typical Maximum 166.000 2.75 5.0 2.5 8.0 10.0 15.0 15 0.9*VDD 0.1*VDD 8 8 4 3 55 45 -10/70 or –40/85 -55 125 ±25, ±50, ±100 0.7*VDD 0.3*VDD 2 Units MHz V V mA uA V V mA mA ns ns % °C °C ppm V Ms 1. A 0.01uF and a 0.1uF capacitor should be located as close to the supply as possible (to ground). 2. Figure 3 defines these parameters. Figure 4 illustrates the operating conditions under which these parameters are tested and specified. 3. Symmetry is measured defined as On Time/Period. 4. Includes calibration tolerance, operating temperature, supply voltage variations, aging and shock and vibration (not under operation). 5. Output will be enabled if enable/disable is left open. tF tR IDD 4 V OH V DD Vs + - .1μF V OL .01μF 1 VC On Time 2 3 IC + 15pF - P er iod Figure 3. Output Waveform Vectron International 267 Lowell Rd, Hudson NH 03051 Figure 4. Typical Output Test Conditions (25±5°C) Tel: 1-88-VECTRON-1 e-mail [email protected] VCS3 Data Sheet Table 3. Electrical Performance, 1.8V option Parameter Symbol Frequency fO Operating Supply Voltage1 VDD Absolute Maximum Voltage Supply Current, Output Enabled IDD < 30 MHz 30.01 to 75 MHz 75.01 to 133 MHz Supply Current, Out disabled IDD Output Logic Levels Output Logic High2 VOH Output Logic Low2 VOL Output Logic High Drive IOH Output Logic Low Drive IOL Output Rise/Fall Time2, fo≤10MHz tR/tF fo>10MHz Duty Cycle3 SYM Operating temperature (ordering option) Storage Temperature Stability4 (ordering option) Output Enable/Disable5 Output Enabled Output Disabled Start-up time Min 0.8 1.62 -0.5 Typical Maximum 133.00 1.98 3.6 1.8 6 8 12 15 0.9*VDD 0.1*VDD 8 8 5 4 55 45 -10/70 or –40/85 -55 125 ±25, ±50, ±100 0.7*VDD 0.3*VDD 2 Units MHz V V mA uA V V mA mA ns ns % °C °C ppm V ms 1. A 0.01uF and a 0.1uF capacitor should be located as close to the supply as possible (to ground) is recommended. 2. Figure 5 defines these parameters. Figure 6 illustrates the operating conditions under which parameters are tested/specified. 3. Symmetry is measured defined as On Time/Period. 4. Includes calibration tolerance, operating temperature, supply voltage variations, aging and shock and vibration (not under operation). 5. Output will be enabled if enable/disable is left open. tR tF IDD V OH 4 Vs VO L V DD + - .1μF O n Time .01μF 1 2 3 IC VC + 15pF - Per iod Figure 5. Output Waveform Vectron International 267 Lowell Rd, Hudson NH 03051 Figure 6. Typical Output Test Conditions (25±5°C) Tel: 1-88-VECTRON-1 e-mail [email protected] VCS3 Data Sheet Enable/Disable Functional Description Under normal operation the Enable/Disable is left open or set to a logic high state. When the E/D is set to a logic low, the oscillator stops and the output is in a high impedance state. This helps reduce power consumption as well as facilitating board testing and troubleshooting. Tri-state Functional Description Under normal operation the tri-state is left open or set to a logic high state. When the tri-state is set to a logic low, the oscillator remains active but the output buffer is in a high impedance state. This helps facilitate board testing and troubleshooting. Table 4. Outline Diagrams, Pad Layout and Pin Out Pin # Symbol Function 1 2 3 4 E/D GND fO VDD Tri-state, Enable/Disable Electrical and Case Ground Output Frequency Supply Voltage YYM T Contact Pads are gold over nickel Figure 7, Package drawing Vectron International 267 Lowell Rd, Hudson NH 03051 Tel: 1-88-VECTRON-1 e-mail [email protected] VCS3 Data Sheet Reliability The VCS3 qualification tests have included: Table 5. Environnemental Compliance Parameter Mechanical Shock Mechanical Vibration Temperature Cycle Solderability Gross and Fine Leak Resistance to Solvents MSL MIL-STD-883 MIL-STD-883 MIL-STD-883 MIL-STD-883 MIL-STD-883 MIL-STD-883 1 Conditions Method 2022 Method 2007 Method 1010 Method 2003 Method 1014 Method 2015 Handling Precautions Although ESD protection circuitry has been designed into the the VCS3, proper precautions should be taken when handling and mounting. VI employs a Human Body Model and a Charged-Device Model (CDM) for ESD susceptibility testing and design protection evaluation. ESD thresholds are dependent on the circuit parameters used to define the model. Although no industry wide standard has been adopted for the CDM, a standard HBM of resistance = 1.5kohms and capacitance = 100pF is widely used and therefore can be used for comparison purposes. Table 6. ESD Ratings Model Human Body Model Charged Device Model Minimum 1000 1500 Conditions MIL-STD-883 Method 3115 JESD 22-C101 Suggested IR profile Devices are built using lead free epoxy and can also be subjected to standard lead free IR reflow conditions, Table 7 shows max temperatures and lower temperatures can also be used e.g. peak temperature of 220C. Table 7. Reflow Profile (IPC/JEDEC J-STD-020) Parameter Symbol Preheat Time Ramp Up 150 sec Min, 200 sec Max R UP 3 C/sec Max tL 60 sec Min, 150 sec Max o Time Above 217 C Time To Peak Temperature o t AMB-P 480 sec Max tP 20 sec Min, 40 sec Max o Time At 260 C (max) Time At 240 °C (max) Ramp Down Value tS tp2 60 sec Max R DN 6 C/sec Max Vectron International 267 Lowell Rd, Hudson NH 03051 o Tel: 1-88-VECTRON-1 e-mail [email protected] VCS3 Data Sheet Ordering Information VCS3 - B 3 B - 75M000 Product Family Output Frequency Crystal Oscillator In MHZ Stability Options Voltage Options Electrical Options A: ±100ppm, -10 to 70°C B: +3.3 Vdc +/-10%, 15pF 3: Tri-state, 45/55% Duty C: ±100ppm, -40 to 85°C G: +2.5Vdc +/-10%, 15pF B: ±50ppm, -10 to 70°C H: +1.8 Vdc +/-10%, 15pF D: ±50ppm, -40 to 85°C E: ±25ppm, -10 to 70°C F: ±25ppm, -40 to 85°C Note: Not all combinations are available. For Additional Information, Please Contact: USA: Vectron International • 267 Lowell Road, Hudson, NH 03051 • Tel: 1-88-VECTRON-1 • Fax: 1-888-FAX-VECTRON www.vectron.com Feb08, 2011 Vectron International 267 Lowell Rd, Hudson NH 03051 Tel: 1-88-VECTRON-1 e-mail [email protected]