Filename: tfs 411.doc Version 1.1 VI TELEFILTER 20.09.2007 Filter specification TFS 411 1/5 Measurement condition Ambient temperature: Input power level: Terminating impedance: Input: Output: 23 0 °C dBm 50 50 Ω Ω Characteristics Remark: The maximum attenuation in the pass band is defined as the insertion loss ae. The nominal frequency fN is fixed at 411 MHz without any tolerance or limit. The values of absolute attenuation aabs are guaranteed for the whole operating temperature range. The frequency shift of the filter in the operating temperature range is included in the production tolerance scheme. Data typ. value Insertion loss (reference level) ae Nominal frequency Pass band Absolute attenuation 2,36 dB tolerance / limit max. 4,8 dB fN - 411 MHz PB - fN ± 2,5 MHz aabs fN - 464,7 MHz … fN - 12,5 MHz 55 dB min. 43 dB fN - 12,5 MHz … fN - 7,5 MHz 50 dB min. 33 dB fN + 20 MHz … fN + 735 MHz 62 dB min. 40 dB fN + 735 MHz … fN + 1235 MHz 40 dB min. 30 dB fN + 1235 MHz … fN + 1535 MHz 35 dB min. 15 dB Operating temperature range OTR Storage temperature range Temperature coefficient of frequency TCf *) - - 10 °C ... + 85°C - - 30 °C ... + 85°C -32 ppm/k *) ∆f(Hz) = TCf(ppm/K) x (T-T0) x fTo(MHz) Generated: Checked / Approved: Tele Filter GmbH Potsdamer Straße 18 D 14 513 TELTOW / Germany Tel: (+49) 3328 4784-0 / Fax: (+49) 3328 4784-30 E-Mail: [email protected] VI TELEFILTER reserves the right to make changes to the product(s) and/or information contained herein without notice. No liability is assumed as a result of their use or application. No rights under any patent accompany the sale of any such product(s) or information. Filename: tfs 411.doc Version 1.1 VI TELEFILTER 20.09.2007 Filter specification TFS 411 2/5 0 0 -10 -1 -20 -2 -30 -3 magnitude in dB magnitude in dB Filter characteristic -40 -50 -60 -4 -5 -6 -70 -7 -80 -8 -90 -9 -100 -10 360 380 400 420 frequency in MHz 440 460 480 407 408 409 410 411 412 frequency in MHz 413 414 415 416 Construction and pin connection (All dimensions in mm) 7 SQ 3,81 +0,2/-0,1 5 411 ● V38 1 3 5 Date code: V W X ... Year + week 2007 2008 2009 0,1 7 0,6 12 0% % d 3 1,78 2,54 1 Ground Input Ground Ground Ground Output Ground Ground 1,2 Max. Date code 1 2 3 4 5 6 7 8 1,78 50 Ω Test circuit L1 2 6 L2 SAW 1, 3, 4, 5, 7, 8 Tele Filter GmbH Potsdamer Straße 18 D 14 513 TELTOW / Germany Tel: (+49) 3328 4784-0 / Fax: (+49) 3328 4784-30 E-Mail: [email protected] VI TELEFILTER reserves the right to make changes to the product(s) and/or information contained herein without notice. No liability is assumed as a result of their use or application. No rights under any patent accompany the sale of any such product(s) or information. Filename: tfs 411.doc Version 1.1 VI TELEFILTER 20.09.2007 Filter specification TFS 411 3/5 Stability characteristics, reliability After the following tests the filter shall meet the whole specification: 1. Shock: 500g, 1 ms, half sine wave, 3 shocks each plane; DIN IEC 68 T2 - 27 2. Vibration: 10 Hz to 500 Hz, 0,35 mm or 5 g respectively, 1 octave per min, 10 cycles per plan, 3 plans; DIN IEC 68 T2 - 6 3. Change of temperature: 4. Resistance to solder heat (reflow): -55 °C to 125°C / 30 min. each / 10 cycles DIN IEC 68 part 2 – 14 Test N reflow possible: three times max.; for temperature conditions refer to the attached "Air reflow temperature conditions" on page 4; This filter is RoHS compliant (2002/95/EG, 2005/618/EG) Packing Tape & Reel: IEC 286 – 3, with exception of value for N and minimum bending radius; tape type II, embossed carrier tape with top cover tape on the upper side; max. pieces of filters per reel: reel of empty components at start: reel of empty components at start including leader: trailer: 3000 min. 300 mm min. 500 mm min. 300 mm Pull Off Direction Tape (all dimensions in mm) W : 12,00 ± 0,3 Po : 4,00 ± 0,1 Do : 1,50 +0,1/-0 E : 1,75 ± 0,1 F : 5,50 ± 0,05 G(min) : 0,75 P2 : 2,00 ± 0,05 P1 : 8,00 ± 0,1 D1(min) : 1,50 Ao : 4,30 ± 0,1 Bo : 4,30 ± 0,1 Ct : 9,5 ± 0,1 P1 Date Code Po Do P2 W G Ct Bo F G E t Ko Typ PIN Marker D1 Ao W 2 Reel (all dimensions in mm) A : 330 W1 : 12,4 +2/-0 W2(max) : 18,4 N(min) : 50 C : 13,0 +0,5/-0,2 A C N W 1 The minimum bending radius is 45 mm. Tele Filter GmbH Potsdamer Straße 18 D 14 513 TELTOW / Germany Tel: (+49) 3328 4784-0 / Fax: (+49) 3328 4784-30 E-Mail: [email protected] VI TELEFILTER reserves the right to make changes to the product(s) and/or information contained herein without notice. No liability is assumed as a result of their use or application. No rights under any patent accompany the sale of any such product(s) or information. Filename: tfs 411.doc Version 1.1 VI TELEFILTER 20.09.2007 Filter specification TFS 411 4/5 Air reflow temperature conditions Conditions Average ramp-up rate (30°C to 217°C) > 100°C > 150°C > 217°C Peak temperature Time within 5°C of actual peak temperature Cool-down rate (Peak to 50°C) Time from 30°C to Peak temperature Exposure less than 3°C/second between 300 and 600 seconds between 240 and 500 seconds between 30 and 150 seconds max. 260°C between 10 and 30 seconds less than 6°C/second no greater than 300 seconds Chip-mount air reflow profile Temperature / °C max. 260°C 217°C max. 300 s 10 ... 30 s Time / s 30 ... 150 s Tele Filter GmbH Potsdamer Straße 18 D 14 513 TELTOW / Germany Tel: (+49) 3328 4784-0 / Fax: (+49) 3328 4784-30 E-Mail: [email protected] VI TELEFILTER reserves the right to make changes to the product(s) and/or information contained herein without notice. No liability is assumed as a result of their use or application. No rights under any patent accompany the sale of any such product(s) or information. Filename: tfs 411.doc VI TELEFILTER Version 1.1 Filter specification 20.09.2007 TFS 411 5/5 History Version Reason of Changes Name Date 1.0 - generation of development specification Dr. Sabah 17.07.2003 1.1 - update the filter specification, add filter characteristic - add test circuit and reliability S. Channaa 20.09.2007 Tele Filter GmbH Potsdamer Straße 18 D 14 513 TELTOW / Germany Tel: (+49) 3328 4784-0 / Fax: (+49) 3328 4784-30 E-Mail: [email protected] VI TELEFILTER reserves the right to make changes to the product(s) and/or information contained herein without notice. No liability is assumed as a result of their use or application. No rights under any patent accompany the sale of any such product(s) or information.