Filename: tfs 924b.doc Version 1.0 VI TELEFILTER 12.06.2006 Filter specification TFS 924B 1/5 Measurement condition Ambient temperature: Input power level: Terminating impedance: Input: Output: 23 0 °C dBm 50 50 Ω Ω Characteristics Remark: The maximum attenuation in the pass band is defined as the insertion loss ae. The nominal frequency fN is fixed at 924,5 MHz without any tolerance or limit. The values of absolute attenuation aabs are guaranteed for the whole operating temperature range. The frequency shift of the filter in the operating temperature range is included in the production tolerance scheme. Data typ. value ae Insertion loss within PB 2,8 Nominal frequency fN - Passband PB - Pass band ripple MHz ... dB max. 3,5 dB 924,5 MHz fN ± 2,9 MHz 0,8 dB max. 2 dB aabs Absolute attenuation 0,3 tolerance / limit 906 MHz 46,0 dB min. 40,0 dB 935 MHz … 945 MHz 25,0 dB min. 20,0 dB 945 MHz … 1400 MHz 57,0 dB min. 40,0 dB 1400 MHz … 2000 MHz 50,0 dB min. 20,0 dB max. 15 dBm Input power level Operating temperature range OTR Storage temperature range Temperature coefficient of frequency TCf * - - 10 °C ... + 60 °C - - 45 °C ... + 85 °C - 39 ppm/K - *) ∆ f(Hz) =TCf(ppm/K) x(T-T0) x fTo (MHz) Generated: Checked / Approved: Tele Filter GmbH Potsdamer Straße 18 D 14 513 TELTOW / Germany Tel: (+49) 3328 4784-0 / Fax: (+49) 3328 4784-30 E-Mail: [email protected] VI TELEFILTER reserves the right to make changes to the product(s) and/or information contained herein without notice. No liability is assumed as a result of their use or application. No rights under any patent accompany the sale of any such product(s) or information. Filename: tfs 924b.doc Version 1.0 VI TELEFILTER 12.06.2006 Filter specification TFS 924B 2/5 0 0 -10 -10 -20 -20 -30 -30 magnitude in dB magnitude in dB Filter characteristic -40 -50 -40 -50 -60 -60 -70 -70 -80 200 400 600 800 1000 1200 frequency in MHz 1400 1600 1800 -80 2000 900 905 910 915 920 925 930 frequency in MHz 935 940 945 Construction and pin connection (All dimensions in mm) 924B ● U24 1 2 3 4 5 6 7 8 Ground Input Ground Ground Ground Output Ground Ground Date code: U V W ... Year + week 2006 2007 2008 50 Ω Test circuit L1 2 6 L2 SAW 1, 3, 4, 5, 7, 8 Tele Filter GmbH Potsdamer Straße 18 D 14 513 TELTOW / Germany Tel: (+49) 3328 4784-0 / Fax: (+49) 3328 4784-30 E-Mail: [email protected] VI TELEFILTER reserves the right to make changes to the product(s) and/or information contained herein without notice. No liability is assumed as a result of their use or application. No rights under any patent accompany the sale of any such product(s) or information. Filename: tfs 924b.doc Version 1.0 VI TELEFILTER 12.06.2006 Filter specification TFS 924B 3/5 Stability characteristics After the following tests the filter shall meet the whole specification: 1. Shock: 500g, 1 ms, half sine wave, 3 shocks each plane; DIN IEC 68 T2 - 27 2. Vibration: 10 Hz to 500 Hz, 0,35 mm or 5 g respectively, 1 octave per min, 10 cycles per plan, 3 plans; DIN IEC 68 T2 - 6 3. Change of temperature: 4. Resistance to solder heat (reflow): -55 °C to 125°C / 30 min. each / 10 cycles DIN IEC 68 part 2 – 14 Test N reflow possible: twice max.; for temperature conditions refer to the attached "Air reflow temperature conditions" on page 4; Packing Tape & Reel: IEC 286 – 3, with exception of value for N and minimum bending radius; tape type II, embossed carrier tape with top cover tape on the upper side; max. pieces of filters per reel: reel of empty components at start: reel of empty components at start including leader: trailer: 3000 min. 300 mm min. 500 mm min. 300 mm Pull Off Direction Tape (all dimensions in mm) W : 12,00 ± 0,3 Po : 4,00 ± 0,1 Do : 1,50 +0,1/-0 E : 1,75 ± 0,1 F : 5,50 ± 0,05 G(min) : 0,75 P2 : 2,00 ± 0,05 P1 : 8,00 ± 0,1 D1(min) : 1,50 Ao : 5,30 ± 0,1 Bo : 5,30 ± 0,1 Ct : 9,5 ± 0,1 P1 Date Code Po Do P2 W G Ct Bo F G E t Ko Typ PIN Marker D1 Ao W 2 Reel (all dimensions in mm) A : 330 W1 : 12,4 +2/-0 W2(max) : 18,4 N(min) : 50 C : 13,0 +0,5/-0,2 A C N W 1 The minimum bending radius is 45 mm. Tele Filter GmbH Potsdamer Straße 18 D 14 513 TELTOW / Germany Tel: (+49) 3328 4784-0 / Fax: (+49) 3328 4784-30 E-Mail: [email protected] VI TELEFILTER reserves the right to make changes to the product(s) and/or information contained herein without notice. No liability is assumed as a result of their use or application. No rights under any patent accompany the sale of any such product(s) or information. Filename: tfs 924b.doc Version 1.0 VI TELEFILTER 12.06.2006 Filter specification TFS 924B 4/5 Air reflow temperature conditions Conditions Average ramp-up rate (30°C to 217°C) > 100°C > 150°C > 217°C Peak temperature Time within 5°C of actual peak temperature Cool-down rate (Peak to 50°C) Time from 30°C to Peak temperature Exposure less than 3°C/second between 300 and 600 seconds between 240 and 500 seconds between 30 and 150 seconds max. 260°C between 10 and 30 seconds less than 6°C/second no greater than 300 seconds Chip-mount air reflow profile Temperature / °C max. 260°C 217°C max. 300 s 10 ... 30 s Time / s 30 ... 150 s Tele Filter GmbH Potsdamer Straße 18 D 14 513 TELTOW / Germany Tel: (+49) 3328 4784-0 / Fax: (+49) 3328 4784-30 E-Mail: [email protected] VI TELEFILTER reserves the right to make changes to the product(s) and/or information contained herein without notice. No liability is assumed as a result of their use or application. No rights under any patent accompany the sale of any such product(s) or information. Filename: tfs 924b.doc VI TELEFILTER Version 1.0 Filter specification 12.06.2006 TFS 924B 5/5 History Version Reason of Changes Name Date 1.0 Generation of filter specification Add typical values, filter characteristic Noack 12.06.2006 Tele Filter GmbH Potsdamer Straße 18 D 14 513 TELTOW / Germany Tel: (+49) 3328 4784-0 / Fax: (+49) 3328 4784-30 E-Mail: [email protected] VI TELEFILTER reserves the right to make changes to the product(s) and/or information contained herein without notice. No liability is assumed as a result of their use or application. No rights under any patent accompany the sale of any such product(s) or information.