Filename: tfs 1900.doc Version 1.1 VI TELEFILTER 15.01.2008 Filter specification TFS 1900 1/5 Measurement condition Ambient temperature: Input power level: Terminating impedance: Input: Output: 23 0 °C dBm 50 50 Ω Ω Characteristics Remark: The maximum attenuation in the pass band is defined as the insertion loss ae. The nominal frequency fN is fixed at 1900,0 MHz without any tolerance or limit. The values of absolute attenuation aabs are guaranteed for the whole operating temperature range. The frequency shift of the filter in the operating temperature range is included in the production tolerance scheme. Data typ. value Insertion loss ae 1.2 Nominal frequency fN - PB Passband dB - tolerance / limit max. fN 3,5 ± dB 1900,0 MHz 17,5 MHz Pass band ripple 0.4 dB max. 1,0 dB Pass band variation 1.1 dB max. 2,0 dB 38 36 38 39 36 dB dB dB dB dB min. min. min. min. min. 35 33 35 35 33 dB dB dB dB dB Group delay ripple within PB 12 ns max. 25 ns Return loss within PB 10 dB min. 7 dB max. 10 aabs Absolute attenuation 0,3 500 1400 2040 2800 MHz MHz MHz MHz MHz ... … … ... … 500 1400 1760 2800 3000 MHz MHz MHz MHz MHz - Input power level Operating temperature range OTR Storage temperature range Temperature coefficient of frequency TCf * - - 40 °C …+ 85 °C - - 40 °C ... + 85 °C -48 ppm/K dBm - *) ∆f(Hz) = TCf(ppm/K) x (T-T0) x fTo(MHz). Generated: Checked / Approved: Tele Filter GmbH Potsdamer Straße 18 D 14 513 TELTOW / Germany Tel: (+49) 3328 4784-0 / Fax: (+49) 3328 4784-30 E-Mail: [email protected] VI TELEFILTER reserves the right to make changes to the product(s) and/or information contained herein without notice. No liability is assumed as a result of their use or application. No rights under any patent accompany the sale of any such product(s) or information. Filename: tfs 1900.doc Version 1.1 VI TELEFILTER 15.01.2008 Filter specification TFS 1900 2/5 Filter characteristic 0 0 -2 9 -6 -4 -12 m a g n itu d e in d B -18 -8 6 VSWR m a g n itu d e in d B -6 -10 -12 -14 3 -24 -30 -36 -42 -16 -48 -18 -54 -20 1850 1860 1870 1880 1890 1900 frequency in MHz 1910 1920 1930 0 1940 -60 0 500 1000 1500 frequency in MHz 2000 2500 3000 Construction and pin connection (All dimensions in mm) 5 6 4 M00 ● W03 1,2 Max. Ground Input Ground Ground Output Ground Date code: W X A ... Year + week 2008 2009 2010 3 2 1 1 2 3 4 5 6 Date code 0,1 3 0,75 3 ±0,15 1,5 1 0,6 6 0,6 4 50 Ω Test circuit L1 2 5 L2 SAW 1, 3, 4, 6 Tele Filter GmbH Potsdamer Straße 18 D 14 513 TELTOW / Germany Tel: (+49) 3328 4784-0 / Fax: (+49) 3328 4784-30 E-Mail: [email protected] VI TELEFILTER reserves the right to make changes to the product(s) and/or information contained herein without notice. No liability is assumed as a result of their use or application. No rights under any patent accompany the sale of any such product(s) or information. Filename: tfs 1900.doc Version 1.1 VI TELEFILTER 15.01.2008 Filter specification TFS 1900 3/5 Stability characteristics, reliability After the following tests the filter shall meet the whole specification: 1. Shock: 500g, 1 ms, half sine wave, 3 shocks each plane; DIN IEC 68 T2 - 27 2. Vibration: 10 Hz to 500 Hz, 0,35 mm or 5 g respectively, 1 octave per min, 10 cycles per plan, 3 plans; DIN IEC 68 T2 - 6 3. Change of temperature: 4. Resistance to solder heat (reflow): -55 °C to 125°C / 30 min. each / 10 cycles DIN IEC 68 part 2 – 14 Test N reflow possible: three times max.; for temperature conditions refer to the attached "Air reflow temperature conditions" on page 4; This filter is RoHS compliant (2002/95/EG, 2005/618/EG) Packing Tape & Reel: IEC 286 – 3, with exception of value for N and minimum bending radius; tape type II, embossed carrier tape with top cover tape on the upper side; max. pieces of filters per reel: reel of empty components at start: reel of empty components at start including leader: trailer: 9000 min. 300 mm min. 500 mm min. 300 mm Pull Off Direction Tape (all dimensions in mm) W : 8,00 ± 0,3 Po : 4,00 ± 0,1 Do : 1,50 +0,1/-0 E : 1,75 ± 0,1 F : 3,50 ± 0,05 G(min) : 0,75 P2 : 2,00 ± 0,05 P1 : 4,00 ± 0,1 D1(min) : 1,50 Ao : 3,25 ± 0,1 Bo : 3,25 ± 0,1 Ct : 5,5 ± 0,1 P1 Date Code Do P2 W G Ct Bo F G E t Po Ko Typ PIN Marker D1 Ao W 2 Reel (all dimensions in mm) A : 330 W1 : 8,4 +1,5/-0 W2(max) : 14,4 N(min) : 50 C : 13,0 +0,5/-0,2 A C N W 1 The minimum bending radius is 45 mm. Tele Filter GmbH Potsdamer Straße 18 D 14 513 TELTOW / Germany Tel: (+49) 3328 4784-0 / Fax: (+49) 3328 4784-30 E-Mail: [email protected] VI TELEFILTER reserves the right to make changes to the product(s) and/or information contained herein without notice. No liability is assumed as a result of their use or application. No rights under any patent accompany the sale of any such product(s) or information. Filename: tfs 1900.doc Version 1.1 VI TELEFILTER 15.01.2008 Filter specification TFS 1900 4/5 Air reflow temperature conditions Conditions Average ramp-up rate (30°C to 217°C) > 100°C > 150°C > 217°C Peak temperature Time within 5°C of actual peak temperature Cool-down rate (Peak to 50°C) Time from 30°C to Peak temperature Exposure less than 3°C/second between 300 and 600 seconds between 240 and 500 seconds between 30 and 150 seconds max. 260°C between 10 and 30 seconds less than 6°C/second no greater than 300 seconds Chip-mount air reflow profile Temperature / °C max. 260°C 217°C max. 300 s 10 ... 30 s Time / s 30 ... 150 s Tele Filter GmbH Potsdamer Straße 18 D 14 513 TELTOW / Germany Tel: (+49) 3328 4784-0 / Fax: (+49) 3328 4784-30 E-Mail: [email protected] VI TELEFILTER reserves the right to make changes to the product(s) and/or information contained herein without notice. No liability is assumed as a result of their use or application. No rights under any patent accompany the sale of any such product(s) or information. Filename: tfs 1900.doc VI TELEFILTER Version 1.1 Filter specification 15.01.2008 TFS 1900 5/5 History Version Reason of Changes Name Date 1.0 - Generation of development specification Strehl 13.07.2007 1.1 - Change of limits in left stop band area - Generation of filter specification S.Springfeldt 15.01.2008 Tele Filter GmbH Potsdamer Straße 18 D 14 513 TELTOW / Germany Tel: (+49) 3328 4784-0 / Fax: (+49) 3328 4784-30 E-Mail: [email protected] VI TELEFILTER reserves the right to make changes to the product(s) and/or information contained herein without notice. No liability is assumed as a result of their use or application. No rights under any patent accompany the sale of any such product(s) or information.