UNISONIC TECHNOLOGIES CO., LM8560

UNISONIC TECHNOLOGIES CO.,
LM8560
CMOS IC
DIGITAL ALARM CLOCK

DESCRIPTION
The UTC LM8560 is alarm equipped digital clock IC with built-in
driver capable of directly driving LED display equipment. As IC
himself the VDD pin for the UTC LM8560 is graded to withstand a
voltage of 15V.

FEATURES
*Single chip P-channel ED MOS LSI
*LED direct drive using time division (duplex configuration)
*Wide operating power supply voltage range
*Built-in alarm function with 24-hour control
*Supports changeover between 12-hour AM/PM and 24-hour
displays
*Built-in battery backup CR oscillator
*Users 50Hz or 60Hz as standard frequency
*Built-in automatic fast forward function for hour and minute
settings
*Built-in sleep timer function (maximum intervals of 59 minutes or 1
hours and 59 minutes)
*Built-in snooze function supporting repeat use
*Equipped with power failure display function
*900Hz output for alarm tone

FUNCTIONS
*Current time display
*Snooze alarm function
*Sleep timer function (maximum intervals of 59 minutes or 1 hours
and 59 minutes)

ORDERING INFORMATION
Order Number
Lead Free
LM8560L-E28-T
Halogen Free
LM8560G-E28-T
www.unisonic.com.tw
Copyright © 2014 Unisonic Technologies Co., Ltd.
Package
Packing
SDIP-28
Tube
1 of 8
QW-R502-005.F
LM8560
CMOS IC

MARKING

PIN CONFIGURATIONS
AM& 10'S HR ag&de
1
28
12/24 HR Select
PM& 10'S HR b
2
27
CR Input
10'S HR c & HR e
3
26
50/60 Hz Select
HR b & g
4
25
50/60 Hz Input
HR c & d
5
24
Snooze Input
HR a & f
6
23
Sleep Display
10'S MIN a & f
7
22
Hour Set
10'S MIN b & g
8
21
Minute Set
10'S MIN c & d
9
20
10'S MIN e &Min e
10
19
Alarm Display
MIN b & g
11
18
Alarm OFF
MIN c & d
12
17
Sleep Output
MIN a & f
13
16
Alarm Output
Colon Output
14
15
VSS
UNISONIC TECHNOLOGIES CO., LTD
www.unisonic.com.tw
VDD
2 of 8
QW-R502-005.F
www.unisonic.com.tw
UNISONIC TECHNOLOGIES CO., LTD
CTR
Tone
Second
Display
20
VDD
Display
Control
15
VSS
GATE
2Hz
F.Sample
S.Sample
50/60Hz
Sec RSTYHLD
T.RST
AL.RST
PWR UP
SEC Disp
T Disp
AL Disp
SL Disp
Input
Control
Reset
Control
Standby DET
OSC
PWR UP
Snooze Input 24
Alarm Display 19
Sleep Display 23
Minute Set 21
Hour Set 22
50/60Hz Input 25
CR Input 27
1/2
1Hz
Control
Sleep CTR
Time&F.Sample
Alarm MIN
CTR
Alarm
OFF
18
Output
Control
UP
PWR
Alarm&F.Sample
Alarm HR
CTR
Time
Sec
16
Alarm
Output
Sleep
Alarm
PF.
DET
Blank&
Flash
50/60 Hz
17
Sleep
Output
Output Decoder/Driver
Colon
Output
14
Time&F.Sample
Time HR.
CTR
GATE
TDisp &
S.Sample
Comparator
Time&S.Sample
Time min.
CTR
SEC CTR
1/25or1/30
28
26
2Hz
12/24 HR
Select
PM&10'S HR b
2
13 MIN a&f
12 MIN c&d
11 MIN b&g
10 10'S MIN e&Min e
9 10'S MIN c&d
8 10'S MIN b&g
7 10'S MIN a&f
HR a&f
HR c&d
5
6
HR b&g
4
3 10'S HR c&HRe
AM&10'S HR ag&de
1

50/60 Hz
Select
LM8560
CMOS IC
BLOCK DIAGRAM
QW-R502-005.F
3 of 8
LM8560

CMOS IC
ABSOLUTE MAXIMUM RATINGS (TA=25°C, VSS=0V)
PARAMETER
Maximum Supply Voltage
Input Voltage1 (50/60Hz Input)
Input Voltage2 (Except 50/60Hz Input)
Output Voltage
Input Clamp Current (50/60Hz Input)
Power Dissipation (Ta=70°C)
Operating Temperature
Storage Temperature

SYMBOL
VDD
VIN1
VIN2
VOUT
lIN
PD
TOPR
TSTG
UNIT
V
V
V
V
mA
mW
C
C
ALLOWABLE OPERATING RANGES (TA=25°C, VSS=0V )
PARAMETER
Supply Voltage
Input “H” Level Voltage1 (50/60Hz Input)
Input “L” Level Voltage1 (50/60Hz Input)
Input “H” Level Voltage2 (Except 50/60Hz Input)
Input “L” Level Voltage2 (Except 50/60Hz Input)
50/60Hz Input Pin Input Voltage (Sets VSS as Reference)

RATING
-15~ +0.3
-15~ +0.3
-15~ +0.3
-15~ +0.3
-0.4 ~+0.4
700
-30 ~ +70
-55 ~ +125
SYMBOL
VDD
VIH1
VIL1
VIH2
VIL2
VAC-IN
MIN.
-14
-1
TYP
MAX.
-7.5
UNIT
V
V
V
V
V
V
VDD+2
-1.5
VDD+2
VLED
ELECTRICAL CHARACTERISTICS (Ta =25°C, VDD = -12V, unless otherwise specified)
PARAMETER
Power failure detection Voltage
SYMBOL
VDD
Consumption Current
ICC
Output “H” Level Current 1
IOH1
Output “H” Level Current 2
IOH2
Output “H” Level Current 3
IOH3
Input “H” Level Current 1
Input “L” Level Current 1
IIH1
IIL1
Input “H” Level Current 2
IIH2
Input “L” Level Current 2
IIL2
Output Leakage Current 1
IOF1
Output Leakage Current 2
IOF2
Output Leakage Current 3
IOF3
Backup Oscillator Stability Factor
FS
Backup Oscillator Accuracy
FA
TEST CONDITIONS
Output set to off and Pull-down
attached input set open
Alarm Output and Sleep Output
VOH =VSS -1V
AM & 10’S HR ag & de (24H mode)
VOUT =VDD-1V
Segment Output Other Than Those
VOUT =VSS -1V
50/60Hz Input, VIN=VSS
50/60Hz Input, VIN=VDD
Input Pins Other Than 50/60Hz Input
VIN =VSS
Input Pins Other Than 50/60Hz Input
VIN =VDD
Alarm Output and Sleep Output
VOUT =VDD
AM & 10’S HR ag & de (24H mode)
VOUT = VDD
Segment Output Other Than Those
Listed Above, VOUT = VDD
Standard Value, 900Hz,
VDD = -9V±10% -10
Standard Value, 900Hz, VDD =
-9V-10
UNISONIC TECHNOLOGIES CO., LTD
www.unisonic.com.tw
MIN. TYP. MAX. UNIT
-7.5
-5
V
5
7
mA
5
mA
36
mA
18
mA
10
10
μA
μA
20
μA
10
μA
10
μA
20
μA
20
μA
-10
10
%
-10
10
%
4 of 8
QW-R502-005.F
LM8560

CMOS IC
DESCRIPTION OF OPERATIONS
* 50/60Hz Input:
Built-in Shumidt circuit enables noise eliminations at 50/60Hz commercial frequencies with use of a simple CR
filter. Built-in pull-up resistor.
* CR Input:
When the AC power supply is interrupted, the time counter switches to a holding state and a built-in oscillator
promptly begins operation. If 50/60Hz input continues for 3 clocks without arriving, this oscillator’s output is activated
and functions as the time counter clock in place of 50/60Hz input. The frequency level of this clock oscillator is
determined according to the CR value. While the above mentioned oscillator is operating using backup mode, all
segment output is switched to OFF.
(Note) When the backup oscillator is in use due to an AC power supply interruption, the 50/60Hz input pin must
be maintained open or at a VSS level.
* 50/60 Selective Input:
When 50/60 selective input is connected to VSS, 50Hz use is enabled. When 50/60 selective input is left open,
VDD is activated using an internal pull-down resistor and the setting is switched to enable use at 60Hz.
* Display Mode Selective Input (Alarm Select/Sleep Select):
Since the pull-down resistor is built-in, selection from four display modes is possible using two SPST switches
(single-pole and single-throw switches). Table 1 shows these display mode selections.
Table1 Display Modes
Selective lnput
Alarm
Sleep
Display Mode
Digit No. 1
Digit No. 2
Digit No. 3
Digit No.4
10’s place for
Minute
Minute
10’s place for
Minute
Hour
VSS
NC
Alarm display
Minute
10’s place for
Minute
NC
VSS
Sleep display
Clear
Hour
Minute
10”s place for
Second
VSS
VSS
Second display
Clear
Minute
Second
Note: Activating VSS using two inputs simultaneously (alarm select and sleep select), the display mode is switched to
display seconds.
NC
NC
Time display
10’s place for
hour, AM/PM
10’s place for
hour, AM/PM
Hour
* Time Setting Input:
There are two setting inputs for use with “hour” and “minute”. Time content settings show in Table2 are possible
by activating VSS to these pins, A pull-down resistor is built-in.
UNISONIC TECHNOLOGIES CO., LTD
www.unisonic.com.tw
5 of 8
QW-R502-005.F
LM8560

CMOS IC
DESCRIPTION OF OPERATIONS(Cont.)
Table 2 Setting contents
Display Mode
Set Input
Functions
Immediately adds 1 to hour digits and then assigns an additional 1, at a
Hour
speed of 2 Hz, after each 1/4 ~ 3/4 second.
Immediately adds 1 to minute digits and then assigns an additional 1, at a
Time
Min
speed of 2 Hz, after each 1/4 ~ 3/4 second. Seconds are rest.
Both
Operates both as outline above.
Hour (note1)
Second digits are cleared to [00].
Second
Min
Time holds.
(Alarm & Sleep)
Resets hour and minute digits as [0:00] when operating in 24-H mode or
Both (note2)
[12:00] when operating in 12-H mode.
Immediately adds 1 to hour digits and then assigns an additional 1, at a
Hour
speed of 2 Hz, after each 1/4 ~ 3/4 second.
Immediately adds 1 to minute digits and then assigns an additional 1, at a
Alarm
Min
speed of 2 Hz, after each 1/4 ~ 3/4 second.
Resets hour and minute digits as [0:00] when operating in 24-hour mode or
Both
[12:00] when operating in 12-hour mode.
Sets sleep counter to [0:59] instantly when VDD is activated to sleep select
Sets Sleep counter to [1:59] instantly when VDD is activated to sleep select
Hour
and hour at the same time.
Sleep
Min
Sleep counter looses 1 at a speed of 2 Hz.
Both
Sleep counter looses 1 at a speed of 2 Hz.
Notes: 1. Once conditions have been switched to reset or hold, input of other functions is locked until both Hour and
Min input have been separated.
2. When the digital reading for seconds is between 30 and 59 seconds, 1 is added to the digits for minutes as
he digital reading for seconds rests to [00].
* 12/24H Select Input:
When this pin set open (VDD), a 12-hour display is enabled whereas connecting this pin to VSS enables the
24-hour display. A pull-down resistor is build-in.
* Power Failure Detection Display:
When activated by drop in power supply, all segments which are lit begin to blink and the unit switches to a
power failure detection display. The power failure detection display is canceled by activating VSS to Hours set or Min
set.
* Alarm Operation and Alarm Output:
The alarm signal outputs when alarm content matches the content of current time. When not rest by either
snooze input or alarm off input, output continues after 1 hour and 59 minutes. This output signal consists of 900Hz
2Hz intermittent (50% duty) modulation signals, When the need arises, a filter can be applied to after the alarm
signal to a DC signal.
*Snooze Input:
When the alarm is sounding and instantly activating VSS to this pin, alarm output is set to OFF for a period
between 8 and 9 minutes after which time the alarm signal is once again output. The snooze function can be used
repeatedly in 1 hours and 59 minutes intervals. A pull-down resistor is built-in Activating VSS to the snooze pin when
the alarm is OFF resets the sleep timer counter to [0:00 ] (This is known as the one-touch sleep timer reset function.)
*Alarm Off Input:
Activating this input pin to VSS instantly sets alarm output to OFF.A pull-down resistor is built-in.
*Sleep Timer and Sleep Output:
Sleep output can turn on the radio and can be set for time intervals of 59 minutes or 1 hour and 59 minute.
Refer to Table 2 for the proper selection procedure (59 minutes or 1 hour and 59 minute selection.) This sleep timer
is constructed using a down counter and when the counter content arrives at [00], output is set to off and the radio
turns off. Adding VSS to snooze input turns sleep output off. When sleep output is on.
UNISONIC TECHNOLOGIES CO., LTD
www.unisonic.com.tw
6 of 8
QW-R502-005.F
www.unisonic.com.tw
UNISONIC TECHNOLOGIES CO., LTD
+
100k
3
4
HR
b&g
6
HR
a&f
9
10'S
MIN
c&d
Duplex
LED
8
10'S
MIN
b&g
Cathode
Common
7
10'S
MIN
a&f
0.47μ
MIN
c&d
d
g
a
b
c
14
Colon
Output
VSS
4.7k
27k
27k
Unit (resistor: Ω , capacitor : F)
This circuit is used as noise
interference stripper for the LW
band. (Backup control is nalbled
except for battery backup mode
2
e
Note: 1 f
13
MIN
a&f
Sleep Alarm
Output Output
17 16 15
10 11 12
10'S
MIN e MIN
&Min e b&g
12 Hour Display and 60Hz Circuit Diagram
5
HR
c&d
20 19 18
2.2k
Minute VDD Alarm Alarm
Set
Display OFF
UTC
LM8560
Hour
Set
23 22 21
50/60 Snooze Sleep
Input Display
Hz
Input
25 24
cycle 2
cycle 1
2
10'S
HR c&
HR e
AM&
10'S PM&
HR
10'S
ag&de HR b
1
50/60
Hz
Select
12/24 CR
HR Input
Select
28 27 26
60 HZ
NC
2.2k
4.7k
+
AC
Backup
Battery
0.001μ
12 HR
NC
R1
110k
f=900Hz

C1
0.015μ
LM8560
CMOS IC
CLOCK-RADIO APPLICATION CIRCUIT (POSITIVE POWER SUPPLY)
QW-R502-005.F
7 of 8
LM8560
cycle 2
12 Hour Display and 60Hz Circuit Diagram
Cathode
Common
Duplex
LED
cycle 1
2
1
Unit (resistor:Ω , capacitor : F)
2. When Battery backup or tone
output is not used, CR input is
conneced to Vss
d
b
c
g
a
f
e
Note: 1.
12 13 14
10 11
9
8
7
6
5
4
MIN
a&f
MIN
c&d
10'S
MIN e MIN
&Min e b&g
10'S
MIN
c&d
10'S
MIN
b&g
10'S
MIN
a&f
HR
c&d
HR
a&f
UTC
LM8560
10'S
HR c& HR
HR e b&g
PM&
10'S
HR b
AM&
10'S
HR
3
Colon
Output
VSS
AC
100k
17 16
Alarm Alarm Sleep Alarm
Display OFF Output Output
20 19 18
Minute VDD
Set
Hour
Set
22 21
23
25 24
50/60 50/60 Snooze Sleep
Input Display
Hz
Hz
Select Input
26
28 27
60 HZ
NC
f=900Hz
0.001μ 12 HR
NC
CR
Input
R1
110k + 330μ
C1
0.015μ
12/24
HR
Select
15
CLOCK APPLICATION CIRCUIT (NEGATIVE POWER SUPPLY)
Piezo
Buzzer

CMOS IC
UTC assumes no responsibility for equipment failures that result from using products at values that
exceed, even momentarily, rated values (such as maximum ratings, operating condition ranges, or
other parameters) listed in products specifications of any and all UTC products described or contained
herein. UTC products are not designed for use in life support appliances, devices or systems where
malfunction of these products can be reasonably expected to result in personal injury. Reproduction in
whole or in part is prohibited without the prior written consent of the copyright owner. The information
presented in this document does not form part of any quotation or contract, is believed to be accurate
and reliable and may be changed without notice.
UNISONIC TECHNOLOGIES CO., LTD
www.unisonic.com.tw
8 of 8
QW-R502-005.F