UTC-IC LM8560

UTC LM8560
MOS IC
DIGITAL ALARM CLOCK
DESCRIPTION
The LM8560 is alarm equipped digital clock IC with built-in
driver capable of directly driving LED display equipment. As IC
himself the VDD pin for the LM8560 is graded to withstand a
voltage of 15V.
FEATURES
*Single chip P-channel ED MOS LSI
*LED direct drive using time division (duplex configuration)
*Wide operating power supply voltage range
*Built-in alarm function with 24-hour control
*Supports changeover between 12-hour AM/PM and 24-hour
displays
*Built-in battery backup CR oscillator
*Users 50Hz or 60Hz as standard frequency
*Built-in automatic fast forward function for hour and minute
settings
*Built-in sleep timer function (maximum intervals of 59 minutes
or 1 hours and 59 minutes)
*Built-in snooze function supporting repeat use
*Equipped with power failure display function
*900Hz output for alarm tone
SDIP-28
FUNCTIONS
*Current time display
*Snooze alarm function
*Sleep timer function (maximum intervals of 59 minutes or 1
hours and 59 minutes)
APPLICATIONS
*Alarm clocks
*Clock radios
UTC
UNISONIC TECHNOLOGIES CO., LTD.
1
QW-R502-005,D
UTC LM8560
MOS IC
PIN CONFIGURATIONS
AM& 10'S HR
ag&de
1
28
12/24 HR Select
PM& 10'S HR b
2
27
CR Input
10'S HR c& HR e
3
26
50/60 Hz Select
HR b&g
4
25 50/60 Hz Input
HR c&d
5
24 Snooze Input
HR a&f
6
23
10'S MIN a&f
7
LM8560
Sleep Display
22 Hour Set
10'S MIN b&g 8
21
Minute Set
10'S MIN c&d 9
20
VDD
10'S MIN e &Min e 10
19
Alarm Display
MIN b&g 11
18
Alarm OFF
MIN c&d 12
17 Sleep Output
MIN a&f 13
16
Alarm Output
Colon Output 14
15
VSS
ABSOLUTE MAXIMUM RATINGS (Ta=25°C, Vss=0V)
PARAMETER
SYMBOL
Maximum Supply Voltage
Input Voltage1
Input Voltage2
Output Voltage
Input Clamp Current
Allowable Power Dissipation
Operating Temperature
Storage Temperature
VDD (max)
VIN1
VIN2
VOUT
lIN
PD (max)
Topr
Tstg
TEST CONDITIONS
50/60Hz Input
Except 50/60Hz Input
50/60Hz Input
Ta=70°C
RATING
UNIT
-15~ +0.3
-15~ +0.3
-15~ +0.3
-15~ +0.3
-0.4 ~+0.4
700
-30 ~ +70
-55 ~ +125
V
V
V
V
mA
mW
°C
°C
ALLOWABLE OPERATING RANGES (Ta=25°C, Vss=0V )
PARAMETER
SYMBOL
Supply Voltage
Input “H” Level Voltage1
Input “L” Level Voltage1
Input “H” Level Voltage2
Input “L” Level Voltage2
50/60Hz Input Pin Input
Voltage
UTC
VDD
VIH1
VIL1
VIH2
VIL2
VAC-IN
TEST CONDITIONS
50/60Hz Input
50/60Hz Input
Except 50/60Hz Input
Except 50/60Hz Input
Sets VSS as Reference
MIN.
-14
-1
TYP.
MAX.
UNIT
-7.5
V
V
V
V
V
V
VDD+2
-1.5
VDD+2
VLED
UNISONIC TECHNOLOGIES CO., LTD.
2
QW-R502-005,D
UTC LM8560
MOS IC
ELECTRICAL CHARACTERISTICS (Ta=25°C, VDD=-12V unless otherwise specified)
PARAMETER
SYMBOL
Input “H” Level Current 1
Input “L” Level Current 1
Input “H” Level Current 2
IIH1
IIL1
IIH2
Input “L” Level Current 2
IIL2
Output “H” Level Current 1
IOH1
Output Leakage Current 1
IOF1
Output “H” Level Current 2
IOH2
Output Leakage Current 2
IOF2
Output “H” Level Current 3
IOH3
Output Leakage Current 3
IOF3
Power failure detection
Voltage
Consumption Current
VDD
Backup Oscillator Stability
Factor
Backup Oscillator
Accuracy
ICC
FS
FA
TEST CONDITIONS
50/60Hz Input, VIN=VSS
50/60Hz Input, VIN=VDD
Input Pins Other Than 50/60Hz Input
VIN=VSS
Input Pins Other Than 50/60Hz Input
VIN=VDD
Alarm Output and Sleep Output
VOH=VSS-1V
Alarm Output and Sleep Output
VOUT=VDD
AM & 10’S HR ag & de (24H mode)
VOUT=VDD-1V
AM & 10’S HR ag & de (24H mode)
VOUT=VDD
Segment Output Other Than Those
VOUT=VSS-1V
Segment Output Other Than Those
Listed Above, VOUT=VDD
MIN.
MAX.
UNIT
10
10
20
µA
µA
µA
10
µA
5
mA
10
36
µA
mA
20
18
µA
mA
20
-7.5
Output set to off and Pull-down attached
input set open
Standard Value,900Hz,
VDD=-9V±10%-10
Standard Value,900Hz, VDD=-9V-10
TYP.
-5
5
µA
V
7
mA
-10
10
%
-10
10
%
DESCRIPTION OF OPERATIONS
*50/60Hz Input:
Built-in Shumidt circuit enables noise eliminations at 50/60Hz commercial frequencies with use of a
simple CR filter. Built-in pull-up resistor.
*CR Input:
When the AC power supply is interrupted, the time counter switches to a holding state and a built-in
oscillator promptly begins operation. If 50/60Hz input continues for 3 clocks without arriving, this
oscillator’s output is activated and functions as the time counter clock in place of 50/60Hz input. The
frequency level of this clock oscillator is determined according to the CR value. While the above
mentioned oscillator is operating using backup mode, all segment output is switched to OFF.
(Note) When the backup oscillator is in use due to an AC power supply interruption, the 50/60Hz input
pin must be maintained open or at a VSS level.
*50/60 Selective Input:
When 50/60 selective input is connected to VSS, 50Hz use is enabled. When 50/60 selective input is
left open, VDD is activated using an internal pull-down resistor and the setting is switched to enable use
at 60Hz.
*Display Mode Selective Input (Alarm Select/Sleep Select):
Since the pull-down resistor is built-in , selection from four display modes is possible using two SPST
switches (single-pole and single-throw switches). Table 1 shows these display mode selections.
UTC
UNISONIC TECHNOLOGIES CO., LTD.
3
QW-R502-005,D
UTC LM8560
MOS IC
Table1 Display Modes
Selective lnput
Alarm
Sleep
Display Mode
Digit No. 1
Digit No. 3
Digit No.4
10’s place for
Minute
Minute
10’s place for
VSS
NC
Alarm display
Hour
Minute
Minute
10’s place for
NC
VSS
Sleep display
Clear
Hour
Minute
Minute
10”s place for
VSS
VSS
Second display
Clear
Minute
Second
Second
Note: Activating VSS using two inputs simultaneously (alarm select and sleep select), the display mode is switched to
display seconds.
NC
NC
Time display
10’s place for
hour, AM/PM
10’s place for
hour, AM/PM
Digit No. 2
Hour
*Time Setting Input:
There are two setting inputs for use with “hour” and “minute”. Time content settings show in Table2 are
possible by activating VSS to these pins, A pull-down resistor is built-in.
Table2 Setting contents
Display Mode
Time
Set Input
Hour
Functions
Immediately adds 1 to hour digits and then assigns an additional 1, at a
speed of 2 Hz, after each 1/4 to 3/4 second.
Min
Immediately adds 1 to minute digits and then assigns an additional 1, at a
speed of 2 Hz, after each 1/4 to 3/4 second. Seconds are rest.
Both
Operates both as outline above.
Second
Hour (note1)
Second digits are cleared to [00].
(Alarm & Sleep)
Min
Time holds.
Both (note2)
Resets hour and minute digits as [0:00] when operating in 24-H mode or
[12:00] when operating in 12-H mode.
Alarm
Hour
Immediately adds 1 to hour digits and then assigns an additional 1, at a
speed of 2 Hz, after each 1/4 to 3/4 second.
Min
Immediately adds 1 to minute digits and then assigns an additional 1, at a
speed of 2 Hz, after each 1/4 to 3/4 second.
Both
Resets hour and minute digits as [0:00] when operating in 24-hour mode or
[12:00] when operating in 12-hour mode.
Sleep
Sets sleep counter to [0:59] instantly when VDD is activated to sleep select
Hour
Sets Sleep counter to [1:59] instantly when VDD is activated to sleep select
and hour at the same time.
Min
Sleep counter looses 1 at a speed of 2 Hz.
Both
Sleep counter looses 1 at a speed of 2 Hz.
Note:1.Once conditions have been switched to reset or hold, input of other functions is locked until both Hour and
Min input have been separated.
2.When the digital reading for seconds is between 30 and 59 seconds, 1 is added to the digits for minutes as
he digital reading for seconds rests to [00].
*12/24H Select Input :
When this pin set open (VDD), a 12-hour display is enabled whereas connecting this pin to VSS enables
the 24-hour display. A pull-down resistor is build-in.
*Power Failure Detection Display :
UTC
UNISONIC TECHNOLOGIES CO., LTD.
4
QW-R502-005,D
UTC LM8560
MOS IC
When activated by drop in power supply, all segments which are lit begin to blink and the unit switches
to a power failure detection display. The power failure detection display is canceled by activating VSS to
Hours set or Min set.
*Alarm Operation and Alarm Output :
The alarm signal outputs when alarm content matches the content of current time. When not rest by
either snooze input or alarm off input, output continues after 1 hour and 59 minutes. This output signal
consists of 900Hz 2Hz intermittent (50% duty) modulation signals, When the need arises , a filter can be
applied to after the alarm signal to a DC signal.
*Snooze Input :
When the alarm is sounding and instantly activating VSS to this pin , alarm output is set to OFF for a
period between 8 and 9 minutes after which time the alarm signal is once again output. The snooze
function can be used repeatedly in 1 hours and 59 minutes intervals. A pull-down resistor is built-in
Activating VSS to the snooze pin when the alarm is OFF resets the sleep timer counter to [0:00 ](This is
known as the one-touch sleep timer reset function.)
*Alarm Off Input :
Activating this input pin to VSS instantly sets alarm output to OFF.A pull-down resistor is built-in.
*Sleep Timer and Sleep Output :
Sleep output can turn on the radio and can be set for time intervals of 59 minutes or 1 hour and 59
minute. Refer to Table 2 for the proper selection procedure (59 minutes or 1 hour and 59 minute
selection.) This sleep timer is constructed using a down counter and when the counter content arrives at
[00], output is set to off and the radio turns off. Adding VSS to snooze input turns sleep output off. When
sleep output is on.
UTC
UNISONIC TECHNOLOGIES CO., LTD.
5
QW-R502-005,D
UTC
CR Input
27
21
19
OSC
PWR UP
Snooze Input 24
Sleep Display 23
AlarmDisplay
Hour Set 22
Minute Set
50/60Hz Input 25
CTR
VSS
VDD
Second
Display
15
2Hz
F.Sample
S.Sample
50/60Hz
Disp
AL
Disp
SL Disp
Sec RSTYHLD
T.RST
AL.RST
PWR UP
SEC
T Disp
Input
Control
GATE
1/2
1Hz
TDisp &
S.Sample
Colon
Output
14
Control
Alarm
OFF
18
Control
Output
UP
PWR
Alarm&F.Sample
Time&F.Sample
Sleep CTR
Alarm HR CTR
Comparator
Time&F.Sample
Time HR.CTR
GATE
Alarm MIN
CTR
Time&S.Sample
Time min.CTR
SEC CTR
1/25 or 1/30
PF.
DET
Alarm
Output
16
Sleep
Alarm
Time
Sec
HR c&d
5
Sleep
Output
17
MIN c&d
MIN a&f
13
MIN b&g
10'S MIN e&Min e
10'S MIN c&d
10'S MIN b&g
12
11
10
9
8
10'S MIN a&f
HR b&g
4
7
10'S HR c&HRe
3
HR a&f
PM&10'S HR b
2
Blank&
Flash
6
AM&10'S HR ag&de
1
50/60 Hz
Output Decoder/Driver
20
Display
Control
Reset
Control
Standby DET
Tone
28
26
2Hz
12/24 HR
Select
Select
50/60 Hz
UTC LM8560
MOS IC
BLOCK DIAGRAM
UNISONIC TECHNOLOGIES CO., LTD.
6
QW-R502-005,D
UTC
AC
+
100k
1
3
cycle 2
4
5
HR
c&d
6
HR
a&f
Duplex
LED
8
10'S
MIN
b&g
Common
Cathode
7
10'S
MIN
a&f
20
19
18
9
10'S
MIN
c&d
10
10'S
MIN e
&Min e
11
MIN
b&g
16
13
MIN
a&f
b
c
This circuit is used as noise interference stripper for
the LW band.(Backup control is enalbled except for
battery backup mode
d
g
a
14
Colon
Output
4.7k
27k
27k
Unit(resistor:Ω , capacitor : F)
2
Note: 1 f
e
12
MIN
c&d
VSS
15
0.47μ
2.2k
4.7k
Sleep Alarm
Output Output
17
2.2k
Minute VDD Alarm Alarm
Set
Display OFF
21
12 Hour Display and 60Hz Circuit Diagram
cycle 1
2
HR
b&g
10'S
HR c&
HR e
Hour
Set
22
LM8560
AM&
10'S
PM&
HR
10'S
ag&de HR b
23
12/24 CR
Input
HR
Select
24
25
50/60 Snooze Sleep
Input Display
Hz
Input
27
50/60
Hz
Select
28
60 HZ
NC
26
12 HR
NC
R1
110k
f=900Hz
+
Battery
Backup
0.001μ
C1
0.015μ
UTC LM8560
MOS IC
CLOCK-RADIO APPLICATION CIRCUIT (Positive Power Supply)
UNISONIC TECHNOLOGIES CO., LTD.
7
QW-R502-005,D
UTC
AC
100k
2
1
+
25
24
330μ
23
4
5
HR
c&d
21
6
HR
a&f
Duplex
LED
8
10'S
MIN
b&g
Common
Cathode
7
10'S
MIN
a&f
20
9
10'S
MIN
c&d
Minute VDD
Set
19
18
17
16
10
12
MIN
c&d
f
e
d
g
a
13
MIN
a&f
15
b
c
14
Colon
Output
VSS
Unit(resistor:Ω , capacitor : F)
2. When Battery backup or tone output is not
used,CR input is conneced to Vss
Note: 1.
11
10'S
MIN e MIN
&Min e b&g
Alarm Alarm Sleep Alarm
Display OFF Output Output
12 Hour Display and 60Hz Circuit Diagram
cycle 2
3
10'S
HR c& HR
HR e b&g
22
Hour
Set
LM8560
50/60 50/60 Snooze Sleep
Input Display
Hz
Hz
Select Input
cycle 1
PM&
10'S
HR b
AM&
10'S
HR
27
CR
Input
28
60 HZ
NC
26
R1
110k
12/24
HR
Select
0.001μ 12 HR
NC
f=900Hz
C1
0.015μ
Piezo
Buzzer
UTC LM8560
MOS IC
CLOCK APPLICATION CIRCUIT (Negative Power Supply)
UNISONIC TECHNOLOGIES CO., LTD.
8
QW-R502-005,D
UTC LM8560
MOS IC
UTC assumes no responsibility for equipment failures that result from using products at values that
exceed, even momentarily, rated values (such as maximum ratings, operating condition ranges, or
other parameters) listed in products specifications of any and all UTC products described or contained
herein. UTC products are not designed for use in life support appliances, devices or systems where
malfunction of these products can be reasonably expected to result in personal injury. Reproduction in
whole or in part is prohibited without the prior written consent of the copyright owner. The information
presented in this document does not form part of any quotation or contract, is believed to be accurate
and reliable and may be changed without notice.
UTC
UNISONIC TECHNOLOGIES CO., LTD.
9
QW-R502-005,D