SPECIFICATIONS FOR LCD MODULE

A MP I R E
SPECIFICATIONS FOR
LCD MODULE
CUSTOMER
CUSTOMER PART NO.
AMPIRE PART NO.
AO-12864XFIQW-00H-A(R)
APPROVED BY
DATE
oApproved For Specifications
oApproved For Specifications & Sample
APPROVED BY
Date : 2006/6/27
CHECKED BY
AMPIRE CO., LTD.
ORGANIZED BY
1
1. RECORD OF REVISION
Revision Date
2006/5/22
2006/6/27
Contents
New Release
Modify LCD driving voltage
Date : 2006/6/27
AMPIRE CO., LTD.
Editor
Lorry
Lorry
2
2 FEATURES
(1) Display format : 128×64 dots, 1/64 duty, 1/9 bias.
(2) Construction : LCD panel , COG and FPC, White LED Back- light.
(3) Display type : FSTN, Transflective, 6 o’clock view
(4) Controller : ST7565 or Equivalent
(5) Extended temperature type.
(6) ROHS compliant
3 MECHANICAL DATA
Parameter
Stand Value
Unit
Dot size
0.485(W) × 0.485(H)
mm
Dot pitch
0.5(W) × 0.5(H)
mm
Active area
63.985 (W) × 31.985(H)
mm
Viewing area
66.8(W) ×35.5 (H)
mm
Module size
89.7(W) × 49.8(H) × 6.0(T)
mm
4 ABSOLUTE MAXIMUM RATINGS
Parameter
Symbol
Min
Max
Unit
Logic Circuit Supply Voltage
VDD-VSS
-0.3
+7.0
V
LCD Driving Voltage
VLCD
0
10
V
Input Voltage
VI
-0.3
VDD+0.3
V
Operating Temp.
TOP
-20
70
°C
Storage Temp.
TSTG
-30
80
°C
Date : 2006/6/27
AMPIRE CO., LTD.
3
5 ELECTRO-OPTICAL CHARACTERISTICS
Parameter
Symbol
Logic Circuit
Supply Voltage
VDD-VSS
--
--
3.3
--
V
LCD Driving
Voltage
Positive
25°C
8.0
8.5
9.0
V
Input Voltage
VIH
--
0.8VDD
--
VDD
V
VIL
IDD
-VDD=3.3V
GND
--
-0.2
0.2VDD
0.5
V
mA
Logic Supply
Current
Condition Min
Typ
Max
----- Electronic Characteristics -----
Unit
Note
1/7BIAS
----- Optical Characteristics (STN ) ----Contrast
CR
--
Rise Time
tr
25°C
Fall Time
tf
Viewing Angle
Range
Frame Frequency
--
14
250
500
ms
25°C
--
300
600
ms
θf
25°C &
--
35
--
θb
CR≥2
--
35
--
θl
--
35
--
θr
fF
--
35
--
--
64
--
25°C
Note 1
Note 2
Note 3
Deg.
Hz
----- White LED Back-light Characteristics ----Parameter
Symbol
Condition
Min
Typ
Max
Forward Voltage
VF
IF=50mA
Forward Current
IF
VF=5V
--
50
--
Luminous of
backlight Surface
LED C.I.E
L
IF=50mA
200
250
--
X
Y
IF=50mA
IF=50mA
0.28
0.29
0.31
0.32
0.34
0.35
5
Unit
Note
V
mA
Supply Voltage
between A&K
Note 4
cd/m2
Note 5
A
* LED Dice number = 3
K
Date : 2006/6/27
AMPIRE CO., LTD.
4
(NOTE 1) Contrast ratio :
CR = (Brightness in OFF state) / (Brightness in ON state)
( NOTE 2 ) Response time :
(NOTE 3) Viewing angle
Date : 2006/6/27
AMPIRE CO., LTD.
5
6 BLOCK DIAGRAM & POWER SUPPLY
Date : 2006/6/27
AMPIRE CO., LTD.
6
7 INTERFACE
No.
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
Symbol
/CS1
/RES
A0
/WR
/RD
D0
D1
D2
D3
D4
D5
D6
D7
VDD
GND
VOUT
CAP3CAP1+
CAP1CAP2CAP2+
V1
V2
V3
V4
V5
VR
C86
P/S
IRS
Function
Chip Select Signal
Reset Signal
H:D0~D7 are Display Data L:D0~D7 are Instruction
Write Signal
Read Signal
Data Bus Line
Data Bus Line
Data Bus Line
Data Bus Line
Data Bus Line
Data Bus Line
Data Bus Line
Data Bus Line
Power Supply for logic
Power Supply(GND)
DC/DC Voltage Converter Output
Capacitor pad for internal DC/DC voltage converter
Capacitor pad for internal DC/DC voltage converter
Capacitor pad for internal DC/DC voltage converter
Capacitor pad for internal DC/DC voltage converter
Capacitor pad for internal DC/DC voltage converter
LCD driver supplies voltages
LCD driver supplies voltages
LCD driver supplies voltages
LCD driver supplies voltages
LCD driver supplies voltages
Voltage Adjustment Pin
Interface Mode Select Signal.
Parallel/Serial Data Select Signal.
IRS=”H” use the internal resistors IRS=”L” Do not use
the internal resistors
Date : 2006/6/27
AMPIRE CO., LTD.
7
8 TIMING CHARACTERISTICS
8080-SYSTEM
Parameter
8080 Series(VDD=2.7~ 3.6V)
Address Hold Time(A0)
Address Setup Time(A0)
System Cycle Time((A0)
Symbol
Min.
tAH8
tAW8
Tcyc8
0
0
240
Control L Pulse Width(/WR)
Control L Pulse Width(/RD)
tCCLW
tCCLR
100
140
ns
ns
Control H Pulse Width(/WR)
Control H Pulse Width(/RD)
Data Setup Time(D0~7)
Address Hold Time
/RD access time
Output Disable Time
tCCHW
tCCHR
tDS8
tDH8
tACC8
tOH8
100
100
40
10
5
ns
ns
ns
ns
ns
ns
Date : 2006/6/27
AMPIRE CO., LTD.
Typ.
Max.
Unit
-
ns
ns
ns
70
50
8
9.
QUALITY AND RELIABILITY
9.1TEST CONDITIONS
Tests should be conducted under the following conditions :
Ambient temperature : 25 ± 5°C
Humidity
: 60 ± 25% RH.
9.2 SAMPLING PLAN
Sampling method shall be in accordance with MIL-STD-105E , level II, normal
single sampling plan .
9.3 ACCEPTABLE QUALITY LEVEL
A major defect is defined as one that could cause failure to or materially reduce the
usability of the unit for its intended purpose. A minor defect is one that does not materially
reduce the usability of the unit for its intended purpose or is an infringement from established
standards and has no significant bearing on its effective use or operation.
9.4 APPEARANCE
An appearance test should be conducted by human sight at approximately 30 cm
distance from the LCD module under flourescent light. The inspection area of LCD panel
shall be within the range of following limits.
Date : 2006/6/27
AMPIRE CO., LTD.
9
10. INSPECTION QUALITY CRITERIA
Item
Description of defects
Function
Dimension
Black spots
Short circuit or Pattern cut
Deviation from drawings
Ave . dia . D
area A
area B
Disregard
D≤0.2
3
4
0.2<D≤0.3
2
3
0.3<D≤0.4
0.4<D
0
1
Width W, Length L
A
B
disregard
W≤0.03
3
4
0.03<W≤0.05
1
1
0.05<W≤0.07 , L≤3.0
See line criteria
Average diameter D 0.2 < D < 0.5 mm
for N = 4 , D > 0.5 for N = 1
Rainbow color or newton ring.
Black lines
Bubbles in
polarizer
Color
uniformity
Glass
Scratches
Contrast
ratio
Response
time
Viewing
angle
Class of
Defects
Major
Major
Minor
Acceptable level
(%)
0.65
1.5
2.5
Minor
2.5
Minor
2.5
Minor
2.5
Obvious visible damage.
Minor
2.5
See note 1
Minor
2.5
See note 2
Minor
2.5
See note 3
Minor
2.5
Zone A active area
Zone B viewing area
Date : 2006/6/27
AMPIRE CO., LTD.
10
11 RELIABILITY
Test Conditions
Test Item
High Temperature Operation
70±3°C , t=96 hrs
Low Temperature Operation
-20±3°C , t=96 hrs
High Temperature Storage
Low Temperature Storage
Thermal Shock Test
Humidity Test
Note
Extend Temp. type
80±3°C , t=96 hrs
1,2
-30±3°C , t=96 hrs
1,2
-30°C ~ 25°C ~ 80°C
30 m in. 5 min. 30 min. ( 1 cycle ) 1,2
Total 5 cycle
40 °C, Humidity 90%, 96 hrs
1,2
Sweep frequency : 10 ~ 55 ~ 10 Hz/1min
Amplitude : 0.75mm
Vibration Test (Packing)
2
Test direction : X.Y.Z/3 axis
Duration : 30min/each axis
Note 1 : Condensation of water is not permitted on the module.
Note 2 : The module should be inspected after 1 hour storage in normal conditions
(15-35°C , 45-65%RH).
Definitions of life end point :
l Current drain should be smaller than the specific value.
l Function of the module should be maintained.
l Appearance and display quality should not have degraded noticeably.
l Contrast ratio should be greater than 50% of the initial value.
Date : 2006/6/27
AMPIRE CO., LTD.
11
12 HANDLING PRECAUTIONS
(1) A LCD module is a fragile item and should not be subjected to strong mechanical shocks.
(2) Avoid applying pressure to the module surface. This will distort the glass and cause a
change in color.
(3) Under no circumstances should the position of the bezel tabs or their shape be modified.
(4) Do not modify the display PCB in either shape or positioning of components.
(5) Do not modify or move location of the zebra or heat seal connectors.
(6) The device should only be soldered to during interfacing. Modification to other areas of
the board should not be carried out.
(7) In the event of LCD breakage and resultant leakage of fluid do not inhale, ingest or make
contact with the skin. If contact is made rinse immediately.
(8) When cleaning the module use a soft damp cloth with a mild solvent, such as Isopropyl or
Ethyl alcohol. The use of water, ketone or aromatic is not permitted.
(9) Prior to initial power up input signals should not be applied.
(10) Protect the module against static electricity and observe appropriate anti-static
precautions.
Date : 2006/6/27
AMPIRE CO., LTD.
12
晶采 光 電 科技
13 OUTLINE DIMENSION
Date : 2006/6/27
AMPIRE CO., LTD.