AM800600J1TMQW

SPECIFICATIONS FOR
LCD MODULE
CUSTOMER
CUSTOMER PART NO.
AMPIRE PART NO.
APPROVED
AM-800600J1TMQW-B0H
BY
DATE
†Approved For Specifications
;Approved For Specifications & Sample
AMPIRE CO., LTD.
2F., No.88, Sec. 1, Sintai 5th Rd., Sijhih City, Taipei County 221,
Taiwan (R.O.C.)台北縣汐止市新台五路一段 88 號 2 樓(東方科學園區 D 棟)
TEL:886-2-26967269 , FAX:886-2-26967196 or 26967270
APPROVED BY
Date : 2009/7/16
CHECKED BY
AMPIRE CO., LTD.
ORGANIZED BY
1
RECORD
Revision Date Page
2009 /7/ 16
Date : 2009/7/16
-
OF
REVISION
Contents
Editor
New Release
John
AMPIRE CO., LTD.
2
1. INSTRUCTION
Ampire 7” Display Module is a color active matrix TFT-LCD that uses amorphous silicon
TFT as a switching device . This model is composed of a TFT-LCD panel , a driving circuit.
This TFT-LCD has a high resolution (800(R.G.B) X 600) and can display up to 262,144
colors.
1.1 Features
(1) Construction : a-Si TFT-LCD with driving system, White LED Backlight ,LED Driver
circuit.
(2) LCD type : Transmissive , Normally White.
(3) Number of the Colors : 262K colors (R,G,B 6 bit digital each)
(4) RGB Interface.
(5) LCD Power Supply Voltage : 3.3V single power input, built-in power supply circuit.
● SVGA (4:3 diagonal) configuration
● Input interface voltage : 3.3V
● LED driver Input voltage : 5.0V
2. PHYSICAL SPECIFICATIONS
Item
Specifications
unit
800RGB (W) x 600(H)
dots
Active area
141.60 (W) x 106.20 (H)
mm
Pixel pitch
59 (W) x 177 (H)
um
Display resolution(dot)
Color configuration
R.G.B -stripe
Overall dimension
155.5(W)x121.5(H)x9.6 (D)
mm
154(TYP.)
g
500nit
cd/m2
Weight
Brightness
Contrast ratio
250
Backlight unit
LED
Display color
262,144
Date : 2009/7/16
AMPIRE CO., LTD.
colors
3
3. ABSOLUTE MAXIMUM RATINGS
Item
Symbol
Min.
Max.
Unit
VCC
-0.3
6
V
AVDD
-0.3
13.5
V
VGH
-0.3
+42
V
VGL
VGH-42
+0.3
V
Operation
-10
70
℃
Storage
-20
80
℃
Power Voltage
Temperature
Range
Note
(1). All of the voltages listed above are with respective to GND=VSSA=0V
(2). Device is subject to be damaged permanently if stresses beyond those absolute
maximum ratings listed above.
4. OPTICAL CHARACTERISTICS
Item
Symbol
Response Time
Tr +Tf
Contrast ratio
Viewing
Angle
CR
Vertical
Θ
Horizontal
Φ
Luminance
Θ=Φ=0°
CR≧10
L
Luminance Uniformity
Color
chromaticity
Conditon
White
ΔL
Wx
Wy
Θ=Φ=0°
Min.
Typ.
Max.
Unit
Note
-
16
--
ms
(1)
--
250
-
-
(2)(3)
--
120
-
--
140
-
Deg.
(5)
--
500
-
cd/m2
(3)(4)
-
70
-
%
(3)(4)
0.26
0.27
0.32
0.33
0.38
0.39
NOTE :
● These items are measured by BM-5A(TOPCON) or CA-1000(MINOLTA) in the dark
room (no ambient light)
●T.B.D means To be define.
Date : 2009/7/16
AMPIRE CO., LTD.
4
(1) Definition of Response Time (White-Black)
(2) Definition of Contrast Ratio
Measure contrast ratio on the below 5 points(refer to figurel,#1~#5point) and take
the average value
Contrast ratio is calculated with the following formula :
Contrast Ratio(CR)=(White)Luminance of ON ÷ (Black)Luminance of OFF
(3) Definition of Luminance :
Measured at the center area of the panel when all the input terminals of LCD panel
are electrically opened.
(4)Definition of Luminance Uniformity :
Measured Maximum luminance[L(MAX)] and Minimum luminance[L(MIN)] on the 5
points
Luminance Uniformity is calculated with the following formula :
ΔL =[ L(MIN)
Date : 2009/7/16
/ L (MAX) ] X 100%
AMPIRE CO., LTD.
5
(5)Definition of Viewing Angle
Φ =(Θx+)+(Θx-)
Date : 2009/7/16
Θ =(Θy+)+(Θy-)
AMPIRE CO., LTD.
6
5. ELECTRICAL CHARACTERISTICS
5.1 TFT LCD Module voltage
ITEM
SYMBOL
MIN
TYP
MAX
UNIT
Power Voltage For LCD
VCC
3.0
3.3
3.6
V
LCD Power Current
Icc
--
150
--
mA
VLED
--
5.0
--
V
VIH
VCC*0.8
--
VCC
V
VIL
0
--
VCC*0.2
V
VIH
3.0
--
5.0
V
VIL
GND
--
0.3
V
Power Voltage For VLED
Logic Input Voltage
ADJ Input Voltage
5.2 Backlight unit
ITEM
LED Voltage
LED Current
Luminance
LED DRIVER
Power Current
Date : 2009/7/16
SYMBOL
VL
IL
L
MIN
----
TYP
10.4
200
500
MAX
----
UNIT
V
mA
cd/m2
ILED(VLED=5V)
-
340
--
mA
AMPIRE CO., LTD.
NOTE
NOTE
7
6. INTERFACE
RGB INTERFACE CN:
Pin No
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
32
33
34
35
36
37
38
39
40
Symbol
NC
NC
NC
VLED
VLED
VLED
Vcc
Vcc
DE
NC(XL)
NC(YU)
ADJ
B5
B4
B3
Vss
B2
B1
B0
Vss
G5
G4
G3
Vss
G2
G1
G0
Vss
R5
R4
R3
Vss
R2
R1
R0
NC(XR)
NC(YD)
DCLK
Vss
NC
Date : 2009/7/16
Function
No connection
No connection
No connection
Power Supply for LED
Power Supply for LED
Power Supply for LED
Power Supply for LCD
Power Supply for LCD
Data Enable
No connection
No connection
Adjust for LED Brightness
Blue Data 5 (MSB)
Blue Data 4
Blue Data 3
Power Ground
Blue Data 2
Blue Data 1
Blue Data 0 (LSB)
Power Ground
Green Data 5 (MSB)
Green Data 4
Green Data 3
Power Ground
Green Data 2
Green Data 1
Green Data 0 (LSB)
Power Ground
Red Data 5 (MSB)
Red Data 4
Red Data 3
Power Ground
Red Data 2
Red Data 1
Red Data 0 (LSB)
No connection
No connection
Clock Signals
Power Ground
No connection
AMPIRE CO., LTD.
8
7. AC Timing characteristic
7-1 Timing Specification.
Symbol
Min.
Typ.
Max
Unit
CLK frequency
FCPH
-
33.79
-
MHz
CLK period
TCPH
-
25.13
-
ns
CLK pulse duty
TCWH
40
50
60
%
TDEH+TDEL
1000
1056
1200
TCPH
DE Pulse Width
TDH
-
800
-
TCPH
DE Frame Blanking
THS
10
28
110
TDEH+TDEL
DE Frame Width
TEP
-
600
-
TDEH+TDEL
Data Setup Time
Tdsu
6
-
-
ns
Data Hold Time
Tdhd
6
-
-
ns
DEN Setup Time
Tesu
6
-
-
ns
PARAMETER
DE Period
7-2 AC Timing Diagrams
Date : 2009/7/16
AMPIRE CO., LTD.
9
7.3 Data input format
Date : 2009/7/16
AMPIRE CO., LTD.
10
8. QUALITY AND RELIABILITY
8.1
TEST CONDITIONS
Tests should be conducted under the following conditions :
Ambient temperature : 25 ± 5°C
Humidity
: 60 ± 25% RH.
8.2
SAMPLING PLAN
Sampling method shall be in accordance with MIL-STD-105E , level II, normal
single sampling plan .
8.3
ACCEPTABLE QUALITY LEVEL
A major defect is defined as one that could cause failure to or materially reduce
the usability of the unit for its intended purpose. A minor defect is one that does not
materially reduce the usability of the unit for its intended purpose or is an infringement from
established standards and has no significant bearing on its effective use or operation.
8.4
APPEARANCE
An appearance test should be conducted by human sight at approximately 30 cm
distance from the LCD module under florescent light. The inspection area of LCD panel
shall be within the range of following limits.
Date : 2009/7/16
AMPIRE CO., LTD.
11
8.5
INCOMING INSPECTION STANDARD FOR
DEFECT TYPE
TFT-LCD PANEL
Note
LIMIT
φ<0.15mm
SPOT
FIBER
VISUAL
DEFECT
INTERNAL
POLARIZER
BUBBLE
Mura
0.15mm≦φ≦0.5mm
0.5mm<φ
0.03mm<W≦0.1mm, L≦
5mm
1.0mm<W, 1.5mm<L
φ<0.15mm
0.15mm≦φ≦0.5mm
0.5mm<φ
DARK DOT
TWO ADJACENT DOT
N=0
N≦3
N=0
Ignore
N≦2
N=0
Note1
Note1
B Grade
C Area O Area
Total
C Area O Area
Total
Note3
N≦0
N≦2
N≦2
N≦2
N≦3
N≦5
Note2
N≦2
N≦3
N≦3
N≦3
N≦5
N≦8
N≦5
N≦6
N≦8
Note2
N≦1
pair
N≦1
pair
N≦1
pair
Note4
N≦4
TOTAL DOT
ELECTRICAL
DEFECT
Note1
It’ OK if mura is slight visible through
6%ND filter
A Grade
BRIGHT DOT
Ignore
N≦4
N≦0
N≦1
pair
N≦1
pair
THREE OR MORE
NOT ALLOWED
ADJACENT DOT
LINE DEFECT
NOT ALLOWED
(1) One pixel consists of 3 sub-pixels, including R,G, and B dot.(Sub-pixel = Dot)
(2) LITTLE BRIGHT DOT ACCEPTABLE UNDER 6 % ND-Filter
[Note1] W : Width[mm], L : Length[mm], N : Number, φ: Average Diameter
[Note2] Bright dot is defined through 6% transmission ND Filter as following.
Date : 2009/7/16
AMPIRE CO., LTD.
12
[Note3]
C Area: Center of display area
C Area: Outer of display area
[Note4]
Judge defect dot and adjacent dot as following. Allow below (as A, B, C and D status)
adjacent defect dots, including bright and dart adjacent dot. And they will be counted 2
defect dots in total quantity.
(1) The defects that are not defined above and considered to be problem shall be reviewed
and discussed by both parties.
(2) Defects on the Black Matrix, out of Display area, are not considered as a defect or counted.
Date : 2009/7/16
AMPIRE CO., LTD.
13
8.6 Reliability Test
Test Item
Test Conditions
High Temperature Operation
70±3°C , t=96 hrs
Low Temperature Operation
-10±3°C , t=96 hrs
High Temperature Storage
80±3°C , t=96 hrs
Low Temperature Storage
Thermal Shock Test
Humidity Test
-20±3°C , t=96 hrs
-10°C ~ 25°C ~ 70°C
30 m in.
5 min. 30 min. ( 1 cycle )
Total 5 cycle
40 °C, Humidity 90%, 96 hrs
Sweep frequency : 10 ~ 55 ~ 10 Hz/1min
Amplitude : 0.75mm
Vibration Test (Packing)
Test direction : X.Y.Z/3 axis
Duration : 30min/each axis
Note 1 : Condensation of water is not permitted on the module.
Note 2 : The module should be inspected after 1 hour storage in normal conditions
(15-35°C , 45-65%RH).
Definitions of life end point :
z
z
z
z
Note
1,2
1,2
1,2
1,2
2
Current drain should be smaller than the specific value.
Function of the module should be maintained.
Appearance and display quality should not have degraded noticeably.
Contrast ratio should be greater than 50% of the initial value.
Date : 2009/7/16
AMPIRE CO., LTD.
14
9. USE PRECAUTIONS
9.1 Handling precautions
1) The polarizing plate may break easily so be careful when handling it. Do not touch,
press or rub it with a hard-material tool like tweezers.
2) Do not touch the polarizing plate surface with bare hands so as not to make it dirty. If
the surface or other related part of the polarizing plate is dirty, soak a soft cotton cloth or
chamois leather in benzine and wipe off with it. Do not use chemical liquids such as
acetone, toluene and isopropyl alcohol. Failure to do so may bring chemical reaction
phenomena and deteriorations.
3) Remove any spit or water immediately. If it is left for hours, the suffered part may deform
or decolorize.
4) If the LCD element breaks and any LC stuff leaks, do not suck or lick it. Also if LC stuff is stuck
on your skin or clothing, wash thoroughly with soap and water immediately.
9.2 Installing precautions
1) The PCB has many ICs that may be damaged easily by static electricity. To prevent
breaking by static electricity from the human body and clothing, earth the human body
properly using the high resistance and discharge static electricity during the operation.
In this case, however, the resistance value should be approx. 1MΩ and the resistance
should be placed near the human body rather than the ground surface. When the indoor
space is dry, static electricity may occur easily so be careful. We recommend the indoor
space should be kept with humidity of 60% or more. When a soldering iron or other
similar tool is used for assembly, be sure to earth it.
2) When installing the module and ICs, do not bend or twist them. Failure to do so may
crack LC element and cause circuit failure.
3) To protect LC element, especially polarizing plate, use a transparent protective plate
(e.g., acrylic plate, glass etc) for the product case.
4) Do not use an adhesive like a both-side adhesive tape to make LCD surface (polarizing
plate) and product case stick together. Failure to do so may cause the polarizing plate to
peel off.
9.3 Storage precautions
1) Avoid a high temperature and humidity area. Keep the temperature between 0°C and
35°C and also the humidity under 60%.
2) Choose the dark spaces where the product is not exposed to direct sunlight or
fluorescent light.
3) Store the products as they are put in the boxes provided from us or in the same
conditions as we recommend.
Date : 2009/7/16
AMPIRE CO., LTD.
15
9.4 Operating precautions
1) Do not boost the applied drive voltage abnormally. Failure to do so may break ICs.
When applying power voltage, check the electrical features beforehand and be careful.
Always turn off the power to the LC module controller before removing or inserting the
LC module input connector. If the input connector is removed or inserted while the
power is turned on, the LC module internal circuit may break.
2) The display response may be late if the operating temperature is under the normal
standard, and the display may be out of order if it is above the normal standard. But this
is not a failure; this will be restored if it is within the normal standard.
3) The LCD contrast varies depending on the visual angle, ambient temperature, power
voltage etc. Obtain the optimum contrast by adjusting the LC dive voltage.
4) When carrying out the test, do not take the module out of the low-temperature space
suddenly. Failure to do so will cause the module condensing, leading to malfunctions.
5) Make certain that each signal noise level is within the standard (L level: 0.2Vdd or less
and H level: 0.8Vdd or more) even if the module has functioned properly. If it is beyond
the standard, the module may often malfunction. In addition, always connect the module
when making noise level measurements.
6) The CMOS ICs are incorporated in the module and the pull-up and pull-down function is
not adopted for the input so avoid putting the input signal open while the power is ON.
7) The characteristic of the semiconductor element changes when it is exposed to light
emissions, therefore ICs on the LCD may malfunction if they receive light emissions. To
prevent these malfunctions, design and assemble ICs so that they are shielded from
light emissions.
8) Crosstalk occurs because of characteristics of the LCD. In general, crosstalk occurs
when the regularized display is maintained. Also, crosstalk is affected by the LC drive
voltage. Design the contents of the display, considering crosstalk.
9.5
Other
1) Do not disassemble or take the LC module into pieces. The LC modules once
disassembled or taken into pieces are not the guarantee articles.
2) The residual image may exist if the same display pattern is shown for hours. This
residual image, however, disappears when another display pattern is shown or the drive
is interrupted and left for a while. But this is not a problem on reliability.
3) AMIPRE will provide one year warranty for all products and three months warrantee for
all repairing products.
Date : 2009/7/16
AMPIRE CO., LTD.
16
10. OUTLINE DIMENSION
Date : 2009/7/16
AMPIRE CO., LTD.
17