10 inch is Amorphous-TFT-LCD (Thin Film Transistor Liquid Crystal Display) module.
This module is composed of a 10” TFT-LCD panel, a driving circuit and backlight system.
This TFT LCD has a 10 (17:10) inch diagonally measured active display area with WSVGA
(1024 horizontal by 600 vertical pixel)resolution.
(1)
(2)
(3)
(4)
(5)
(6)
(7)
(8)
(9)
Construction: 10” a-Si TFT active matrix, White LED Backlight .
Resolution (pixel): 1024(R.G.B) X600
Number of the Colors : 262K colors ( R , G , B 6 bit digital each)
Display mode : Normally White
Interface: One channel LVDS interface.
Power Supply Voltage: 3.3V single power input.
Build-in LED Driver IC. (5.0V Input Voltage).
Viewing Direction: 6 O’clock.
RoHS Compliance.
2. PHYSICAL SPECIFICATIONS
Item
LCD size
Specifications
unit
10 inch (Diagonal)
Resolution
1024 x 3(RGB) x 600
dot
Pixel pitch
0.21525(W) x 0.21525(H)
mm
Active area
220.42(W) x 129.15(H)
mm
Module size
235.0(W) x 145.8(H) x 5.5(D)
mm
Surface treatment
Antiglare, Hard-Coating (3H) with EWV film
Color arrangement
RGB-stripe
interface
Weight
Date : 2009/2/2
LVDS
253(Typ)
AMPIRE CO., LTD.
g
3
3. ABSOLUTE MAX. RATINGS
(GND = AVSS = 0V)
Values
Item
Symbol
UNIT
VLED
Min.
Max.
-0.3
6.0
Power voltage
Note
V
VDD
-0.3
6.0
Operation temperature
TOP
-20
70
℃
Storage temperature
TST
-30
80
℃
4. Mechanical Information
Item
Module size
Min.
Typ.
Max.
UNIT
Horizontal
234.5
235
235.5
mm
Vertical
145.3
145.8
146.3
mm
Depth
-
5.5
5.8
mm
-
253
270
g
Weight
5. ELECTRICAL CHARACTERISTICS
5-1 Typical Operation Conditions
Values
Item
Power voltage
Power Supply
Voltage For LED
Current of power
supply
Note 1: VDD-dip condition :
Symbol
UNIT
Note
3.6
V
Note1
5.0
5.3
V
0.3
-
A
Min.
Typ.
Max.
VDD
3.0
3.3
VLED
4.7
IDD
-
VDD=3.3V
Black pattern
when 2.7V≦VDD<3.0V,td≦10ms.
VDD>3.0V,VDD-dip condition should be same as VDD-turn-con condition.
Date : 2009/2/2
AMPIRE CO., LTD.
4
5-2 Switching Characteristics for LVDS Receiver
Item
Differential Input High
Threshold
Differential Input Low
Threshold
Input current
Differential input
Voltage
Common Mode
Voltage Offset
Symbol
Min.
Typ.
Max.
Unit
Condition
Vth
--
--
100
mV
VCM=1.2V
Vtl
-100
--
--
mV
IIN
-10
--
+10
uA
|VID|
0.1
--
0.6
V
VCM
(|VID|/2)
1.25
1.8-0.4-(|VID|/2)
V
5-3 Bit Mapping & Interface Definition
Date : 2009/2/2
AMPIRE CO., LTD.
5
6. Optical Specifications
Values
Item
Symbol
Condition
Min. Typ.
Note
degree
Note1
Note2
Max.
θL
60
70
--
θR
60
70
--
(CR≧10)
Viewing angle
Unit
θU
40
50
--
θD
50
60
--
TR
--
5
7
msec
TF
--
20
28
msec
CR
400
500
--
--
0.26
0.31
0.36
--
WY
0.28
0.33
0.38
--
Luminance
L
200
250
--
cd/㎡
Note4
Luminance uniformity
YU
70
--
--
%
Note5
Response time
Contrast ratio
Note3
WX
Color chromaticity
Normal
θ=Φ=0°
Note2
Note1
Note4
6.1 Measuring surrounding
● dark room
● LED current : IL=200mA
● Ambient temperature:25±2oC
● 15min. warm-up time.
Date : 2009/2/2
AMPIRE CO., LTD.
6
6.2 Measuring Equipment
The optical characteristics should be measured in dark room. After 30 minutes
operation, the optical properties are measured at the center point of the LCD screen.
(Response time is measured by Photo detector TOPCON BM-7 of view : 1° / Height :
120mm.)
Note 1 : Definition of viewing angle range
Note 2 : Definition of Contrast Ratio (CR) :
measured at the center point of panel
Luminance with all pixels white
CR =
----------------------------------------------Luminance with all pixels black
Date : 2009/2/2
AMPIRE CO., LTD.
7
Note 3 : Definition of Response time : Sum of TR and TF
Note 4 : Definition of optical measurement setup
Optical Detector
LCD
Brightness gauge
BM-7 (Topcon)
LED
LED:ON, LIGHT:OFF
Note 5 : Definition of brightness uniformity
(Min Luminance of 9 points)
Luminance uniformity =
Date : 2009/2/2
------------------------------------------------×100%
(Max Luminance of 9 points)
AMPIRE CO., LTD.
8
7. INTERFACE
TFT LCD Panel Driving Section
Pin No.
Symbol
Description
1
GND
Ground
2
VDD
3.3V Power
3
VDD
3.3V Power
4
V_EDID
5
ADJ
3.3V Power for EDID
Adjust for LED brightness
6
CLK_EDID EDID Clock Input
7
DATA_EDID EDID Data Input
8
RXIN0-
LVDS Signal - channel0-
9
RXIN0+
LVDS Signal+ channel0+
10
GND
11
RXIN1-
Data Input channel1-
12
RXIN1+
Data Input channel1+
13
GND
14
RXIN2-
Data Input channel2-
15
RXIN2+
Data Input channel2+
16
GND
Note*
Ground
Ground
Ground
17
RXCLKIN- Data Input CLK-
18
RXCLKIN+ Data Input CLK+
19
GND
20
NC
NC
21
NC
NC
22
GND
Ground
23
GND
Ground
24
VLED
VLED Power +5V
25
VLED
VLED Power +5V
Date : 2009/2/2
Note
Ground
AMPIRE CO., LTD.
9
26
VLED
VLED Power +5V
27
NC
NC
28
NC
NC
29
NC
NC
30
NC
NC
Note* : The brightness of LCD panel could be changed by adjusting ADJ
1)ADJ adjust brightness to control Pin. Pulse duty the bigger the brighter.
2) ADJ signal=0~3.3V operation frequency:20kHz
Date : 2009/2/2
AMPIRE CO., LTD.
10
8. BLOCK DIAGRAM :
TFT LCD Module
Date : 2009/2/2
AMPIRE CO., LTD.
11
9. Interface Timing (DE mode)
Item
Symbol
Min.
Typ.
Max.
Unit
Frame Rate
--
55
60
65
Hz
Frame Period
t1
612
625
638
line
Vertical Display Time
t2
600
600
600
line
Vertical Blanking Time
t3
12
25
38
line
1 Line Scanning Time
t4
1160
1200
1240
clock
Horizontal Display Time
t5
1024
1024
1024
clock
Horizontal Blanking Time
t6
136
176
216
clock
Clock Rate
t7
39
45
51.42
MHz
Timing Diagram of Interface Signal (DE mode)
Date : 2009/2/2
AMPIRE CO., LTD.
12
10. Power On/Off Sequence
Item
Min.
Typ.
Max.
Unit
TP1
0.5
--
10
msec
TP2
0
--
50
msec
TP3
0
--
50
msec
TP4
500
--
--
msec
TP5
200
--
--
msec
TP6
200
--
--
msec
Remark
Note:
(1) The supply voltage of the external system for the module input should be the same as the definition of
VDD.
(2) Apply the lamp voltage within the LCD operation range. When the back-light turns on before the LCD
operation or the LCD turns off before the back-light turns off, the display may momentarily become white.
(3) In case of VDD = off level, please keep the level of input signal on the low or keep a high impedance.
(4) TP4 should be measured after the module has been fully discharged between power off and on period.
(5) Interface signal shall not be kept at high impedance when the power is on.
Date : 2009/2/2
AMPIRE CO., LTD.
13
11. RELIABILITY TEST CONDITIONS
Item
Test Conditions
High Temperature Storage
Ta = 80℃
Low Temperature Storage
Ta = -30℃ 240 hrs
High Temperature Operation
Ts = 70℃ 240 hrs
Low Temperature Operation
Ta = -20℃ 240 hrs
Operate at High Temperature
and Humidity
240 hrs
+60℃, 90%RH
240 hrs
Thermal Shock
-30℃ /30 min ~ +80℃ /30 min 200 cycles
Vibration Test
1.Random:
1.04G, 10~500Hz, X/Y/Z,
30min/each direction
2.Sine:
Freq. Range: 8~33.3Hz
Stoke: 1.3mm
Sweep: 2.9G, 33.3~400Hz
X/Z: 2hr, Y: 4hr, cyc: 15min
Shock
Half-Sine, 220G, 2ms, ±XYZ, 1time
Vibration (with carton)
Random Vibration :
0.015G*G/Hz from 5-200HZ, -6dB/Octave
from 200-400Hz
2 hours for each direction of X. Y. Z.
Drop Test(with Carton)
Height : 60 cm
1 comer, 3 edges, 6 surfaces
Electro Static Discharge
Note
+/-200V,200pF(0Ω) 1 time/connector
Note: There is no display function NG issue occurred, all the cosmetic specification is
judged before the reliability stress.
Date : 2009/2/2
AMPIRE CO., LTD.
14
12. General Precautions
12.1 Use Restriction
This product is not authorized for use in life supporting systems, aircraft navigation control
systems, military systems and any other application where performance failure could be
life-threatening or otherwise catastrophic.
12.2 Disassembling or Modification
Do not disassemble or modify the module. It may damage sensitive parts inside LCD
module, and may cause scratches or dust on the display. Ampire does not warrant the
module, if customers disassemble or modify the module.
12.3 Breakage of LCD Panel
12.3.1.If LCD panel is broken and liquid crystal spills out, do not ingest or inhale liquid
crystal, and do not contact liquid crystal with skin.
12.3.2. If liquid crystal contacts mouth or eyes, rinse out with water immediately.
12.3.3. If liquid crystal contacts skin or cloths, wash it off immediately with alcohol and
rinse thoroughly with water.
12.3.4. Handle carefully with chips of glass that may cause injury, when the glass is
broken.
12.4 Electric Shock
12.4.1. Disconnect power supply before handling LCD module.
12.4.2. Do not pull or fold the LED cable.
12.4.3. Do not touch the parts inside LCD modules and the fluorescent LED’s connector
or cables in order to prevent electric shock.
12.5 Absolute Maximum Ratings and Power Protection Circuit
12.5.1. Do not exceed the absolute maximum rating values, such as the supply voltage
variation, input voltage variation, variation in parts’ parameters, environmental
temperature , etc., otherwise LCD module may be damaged.
12.5.2. Please do not leave LCD module in the environment of high humidity and high
temperature for a long time.
12.5.3. It’s recommended to employ protection circuit for power supply.
Date : 2009/2/2
AMPIRE CO., LTD.
15
12.6 Operation
12.6.1 Do not touch, push or rub the polarizer with anything harder than HB pencil lead.
12.6.2 Use fingerstalls of soft gloves in order to keep clean display quality, when persons
handle the LCD module for incoming inspection or assembly.
12.6.3 When the surface is dusty, please wipe gently with absorbent cotton or other soft
material.
12.6.4 Wipe off saliva or water drops as soon as possible. If saliva or water drops
contact with polarizer for a long time, they may causes deformation or color
fading.
12.6.5 When cleaning the adhesives, please use absorbent cotton wetted with a little
petroleum benzine or other adequate solvent.
12.7 Mechanism
Please mount LCD module by using mounting holes arranged in four corners tightly.
12.8 Static Electricity
12.8.1 Protection film must remove very slowly from the surface of LCD module to
prevent from electrostatic occurrence.
12.8.2 Because LCD module use CMOS-IC on circuit board and TFT-LCD panel, it is
very weak to electrostatic discharge. Please be careful with electrostatic
discharge. Persons who handle the module should be grounded through
adequate methods.
12.9 Strong Light Exposure
The module shall not be exposed under strong light such as direct sunlight. Otherwise,
display characteristics may be changed.
12.10 Disposal
When disposing LCD module, obey the local environmental regulations.
Date : 2009/2/2
AMPIRE CO., LTD.
16
13. OUTLINE DIMENSION
Unit:mm
Date : 2009/2/2
AMPIRE CO., LTD.
17
14. EDID TABLE
Date : 2009/2/2
AMPIRE CO., LTD.
18
Date : 2009/2/2
AMPIRE CO., LTD.
19
Date : 2009/2/2
AMPIRE CO., LTD.
20
Date : 2009/2/2
AMPIRE CO., LTD.
21