SPECIFICATIONS FOR LCD MODULE

SPECIFICATIONS FOR
LCD MODULE
CUSTOMER
CUSTOMER PART NO.
AMPIRE PART NO.
APPROVED
AM-640480GHTNQW-00H
BY
DATE
† Approved For Specifications
; Approved For Specifications & Sample
AMPIRE CO., LTD.
2F., No.88, Sec. 1, Sintai 5th Rd., Sijhih City, Taipei County 221,
Taiwan (R.O.C.)台北縣汐止市新台五路一段 88 號 2 樓(東方科學園區 D 棟)
TEL:886-2-26967269 , FAX:886-2-26967196 or 26967270
APPROVED BY
Date : 2008/12/8
CHECKED BY
AMPIRE CO., LTD.
ORGANIZED BY
1
RECORD
Revision Date Page
2008/12/8
--
Date : 2008/12/8
OF
REVISION
Contents
Editor
New Release
John
AMPIRE CO., LTD.
2
1. Features
5.7 inch Amorphous-TFT-LCD (Thin Film Transistor Liquid Crystal Display) module.
This module is composed of a 5.7” TFT-LCD panel, a driver circuit and backlight unit.
(1) Construction: 5.7” a-Si color TFT-LCD, White LED Backlight and PCB.
(2) Resolution (pixel): 640(R.G.B) X 480
(3) Number of the Colors : 262K colors ( R , G , B 6 bit digital each)
(4) LCD type : Transmissive Color TFT LCD (normally White)
(5) Interface: 40 pin
(6) Power Supply Voltage: 3.3V single power input. Built-in power supply circuit.
Viewing Direction: 12 O’clock ( The direction it’s hard to be discolored )
2. PHYSICAL SPECIFICATIONS
Item
Display resolution(dot)
Display area
Pixel pitch
Specifications
unit
640RGB (W) x 480(H)
dots
115.2 (W) x 86.4 (H)
mm
0.1815 (W) x 0.1815 (H)
mm
Color configuration
R.G.B Vertical stripe
Overall dimension
131.0(W)x102.2(H)x11.6(D)---(Typ)
Surface treatment
Antiglare , Hard-Coating(3H)
Brightness
mm
cd/m2
350
Contrast ratio
250 : 1
Backlight unit
LED
3. ABSOLUTE MAXIMUM RATINGS
3.1 Absolute max. ratings
3.1.1 Electrical Absolute max. ratings
ITEM
Power Supply Voltage
Signal Input Voltage
SYMBOL
MIN
MAX
UNIT
Vcc
-0.5
5
V
-0.5
Vcc + 0.5
V
NOTE
Note 1
Note 1: Hsync, Vsync, DTMG, DCLK, R0~R5, G0~G5, B0~B5
Date : 2008/12/8
AMPIRE CO., LTD.
3
3.1.2 Environmental Absolute max. ratings
OPERATING
Item
Temperature
STORAGE
MIN
MAX
MIN
MAX
-20
70
-30
80
Humidity
Note1
Note1
Corrosive Gas
Not Acceptable
Not Acceptable
Remark
Note2,3,4,5,6,7
Note1 : Ta <= 40℃ : 85% RH max
Ta > 40℃ : Absolute humidity must be lower than the humidity of 85%RH
at 40℃
Note2 : For storage condition Ta at -30℃ < 48h , at 80℃ < 100h
For operating condition Ta at -20℃ < 100h
Note3 : Background color changes slightly depending on ambient temperature.
This phenomenon is reversible.
Note4 : The response time will be slower at low temperature.
Note5 : Only operation is guarantied at operating temperature. Contrast ,
response time, another display quality are evaluated at +25℃
Note6 : When LCM is operated over 40℃ ambient temperature, the ILED of the
LED back-light should be follow :
105
84
63
42
21
-20 -10
0
10 20 30 40 50 60 70
Ambient Temperature Ta (℃)
Note7 : This is panel surface temperature, not ambient temperature.
Note8 : When LCM be operated over than 40℃ , the life time of the LED
back-light will be reduced.
Date : 2008/12/8
AMPIRE CO., LTD.
4
4. ELECTRICAL CHARACTERISTICS
4-1 DC Electrical characteristic of the LCD
ITEM
Power Voltage For LCD
Logic Input Voltage
LCD Power Current
SYMBOL
MIN
TYP
MAX
UNIT
VCC
3.0
3.3
3.6
V
VIH
VCC*0.7
--
VCC
V
VIL
0
--
VCC*0.3
V
Icc
--
82
--
mA
NOTE
Note1
Note2
Note1: Hsync, Vsync, DTMG, DCLK, R0~R5, G0~G5, B0~B5
Note2: fV =60Hz , Ta=25℃ , Display pattern : All Black
4-2 Electrical characteristic of LED Back-light
Paramenter
Symbol
Min.
Typ.
Max.
Unit
LED voltage
VAK
9.0
9.12
9.24
V
LED forward
current
ILED
--
84
91
mA
Condiction
ILED
=84mA,Ta=25℃
Ta=25℃
ILED = 84mA
A
K
Date : 2008/12/8
AMPIRE CO., LTD.
5
5. INTERFACE
Pin No
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
32
33
34
35
36
37
38
39
40
Symbol
VDD
VDD
U/D
L/R
VSYNC
DEN
VSS
DCLK
VSS
HSYNC
VSS
B5
B4
B3
VSS
B2
B1
B0
VSS
G5
G4
G3
VSS
G2
G1
G0
VSS
R5
R4
R3
VSS
R2
R1
R0
NC
VSS
NC
NC
NC
NC
Date : 2008/12/8
Function
Power Supply for Logic
Vertical Display mode Control (Note 1)
Horizontal Display mode Control (Note 1)
Vertical Sync Pulse (Note 2)
Timing Signal for Data (Note 2)
GND
Dot Clock
GND
Horizontal Sync Pulse (Note 2)
GND
Blue Data
GND
Blue Data
GND
Green Data
GND
Green Data
GND
Red Data
GND
Red Data
No Connection
GND
No Connection
AMPIRE CO., LTD.
6
Note 1: Vertical Display mode and Horizontal Display mode control.
L/R : H, U/D : H
L/R : L, U/D : H
L/R : H, U/D : L
L/R : L, U/D : L
Note 2: It will auto detect which mode is used. If DEN signal is fixed low, SYNC mode
is used. Otherwise, DE mode is used.
(1) Use DE mode : DEN only, VSYNC and HSYNC short to GND
(2) Use SYNC mode : VSYNC and HSYNC only, DEN short to GND.
Date : 2008/12/8
AMPIRE CO., LTD.
7
6. INPUT SIGNAL :
6-1 Timing Specification.
6.1.1 AC Electrical Characteristics
Spec.
PARAMETER
Symbol
HS setup time
THST
10
ns
HS hold time
THHD
10
ns
VS setup time
TVST
10
ns
VS hold time
TVHD
10
ns
Data setup time
TDSU
10
ns
Date hold time
TDHD
10
ns
DEN setup time
TESU
10
ns
Min.
Typ.
Max
Unit
6.1.2 Digital Parallel RGB interface
Spec.
PARAMETER
Symbol
CLK frequency
FCPH
CLK period
TCPH
-
39.7
-
ns
CLK pulse duty
TCWH
40
50
60
%
HS period
TH
-
800
-
TCPH
HS pulse width
TWH
5
30
-
TCPH
HS-first horizontal data
time
THS
112
144
175
TCPH
DEN pulse width
TEP
-
640
-
TCPH
VS pulse width
TWV
1
3
5
TH
VS-DEN time
TSTV
-
35
-
TH
VS period
TV
-
525
-
TH
Min.
Typ.
Max
25.175
Unit
MHz
Note: When SYNC mode is used, 1st data start from 144th CLK after HS falling (when
STHD[5:0]=00000)
Date : 2008/12/8
AMPIRE CO., LTD.
8
PARAMETER
Symbol
OEV pulse width
TOEV
CKV pulse width
TCKV
HS-CKV time
Spec.
Min.
Unit
Typ.
Max
100
-
TCPH
-
96
-
TCPH
T1
-
52
-
TCPH
HS-OEV time
T2
-
8
-
TCPH
HS-POL time
T3
-
72
-
TCPH
STV setup time
TSUV
-
46
-
TCPH
STV pulse width
TWSTV
-
1
-
TH
6-2 Timing chart
Date : 2008/12/8
AMPIRE CO., LTD.
9
Date : 2008/12/8
AMPIRE CO., LTD.
10
6-3 Color Data Assignment
COLOR
BASIC
COLOR
RED
GREEN
BLUE
Input
Data
R DATA
R5
MSB
G DATA
R4
R3
R2
R1
R0
G5
LSB
MSB
BLACK
RED(63)
GREEN(63)
BLUE(63)
CYAN
MAGENTA
YELLOW
WHITE
RED(0)
RED(1)
RED(2)
0
1
0
0
0
1
1
1
0
0
0
0
1
0
0
0
1
1
1
0
0
0
0
1
0
0
0
1
1
1
0
0
0
0
1
0
0
0
1
1
1
0
0
0
0
1
0
0
0
1
1
1
0
0
1
0
1
0
0
0
1
1
1
0
1
0
0
0
1
0
1
0
1
1
0
0
0
RED(62)
RED(63)
GREEN (0)
GREEN (1)
GREEN (2)
1
1
0
0
0
1
1
0
0
0
1
1
0
0
0
1
1
0
0
0
1
1
0
0
0
0
1
0
0
0
0
0
0
0
0
GREEN (62)
GREEN (63)
BLUE (0)
BLUE (1)
BLUE (2)
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
1
1
0
0
0
BLUE (62)
BLUE (63)
0
0
0
0
0
0
0
0
0
0
0
0
0
0
NOTE :
G4
0
0
1
0
1
0
1
1
0
0
0
∣
0
0
0
0
0
∣
1
1
0
0
0
∣
0
0
B DATA
G0
B5
LSB
MSB
0
0
1
0
1
0
1
1
0
0
0
0
0
1
0
1
0
1
1
0
0
0
0
0
0
0
0
0
0
0
0
1
1
1
0
0
0
1
1
0
0
0
0
0
0
0
G3
G2
G1
0
0
1
0
1
0
1
1
0
0
0
0
0
1
0
1
0
1
1
0
0
0
0
0
0
0
0
B3
B2
B1
0
0
0
1
1
1
0
1
0
0
0
0
0
0
1
1
1
0
1
0
0
0
0
0
0
1
1
1
0
1
0
0
0
0
0
0
1
1
1
0
1
0
0
0
0
0
0
1
1
1
0
1
0
0
0
0
0
0
1
1
1
0
1
0
0
0
0
0
0
1
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
1
1
0
0
0
0
1
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
1
0
0
0
1
0
0
0
0
0
1
1
1
1
1
1
1
1
1
1
0
1
(1) Definition of Gray Scale , Color(n) : n is series of Gray Scale
The more n value is the bright Gray Scale
(2) Data : 1-High , 0-Low
Date : 2008/12/8
AMPIRE CO., LTD.
B0
B4
11
LSB
7. OPTICAL CHARACTERISTICS
Item
Symbol
Condition
Min.
Typ.
Max.
Unit
Note
Contrast ratio
CR
200
250
--
--
(1)(2)(3)
Luminance
Lw
200
350
-
cd/m2
(1)(3)
Luminance Uniformity
ΔL
70
75
-
%
(1)(3)
--
50
--
ms
(1)(3)(5)
80
100
-
120
140
-
Deg.
(1)(2)(4)
0.566
0.616
0.666
0.302
0.352
0.402
0.308
0.358
0.408
0.518
0.568
0.618
0.096
0.146
0.196
--
(1)(3)
0.086
0.136
0.186
0.296
0.346
0.396
0.328
0.378
0.428
Response Time
( White – Black )
Viewing
Angle
Tr +Tf
Vertical
Θ
Horizontal
Φ
Red
Color
chromaticity
Point - 5
Θ=Φ=0°
Green
Blue
White
Rx
Ry
Gx
Gy
Bx
By
Wx
Wy
CR≧10
Point – 5
Point - 5
Θ=Φ=0°
NOTE :
(1) Measure conditions : 25℃±2℃ , 60±10%RH under 10Lux , in the dark room by
BM-7TOPCON) ,viewing 2° , VCC=3.3V , VDD=3.3V
(2) Definition of Contrast Ratio :
Contrast Ratio (CR) = (White) Luminance of ON ÷ (Black) Luminance of OFF
(3) Definition of Luminance :
Definition of Luminance Uniformity
Measure white luminance on the point 5 as figure9-1
Measure white luminance on the point 1 ~ 9 as figure9-1
ΔL = [ L(MIN) / L(MAX)] X 100%
Date : 2008/12/8
AMPIRE CO., LTD.
12
(4) Definition of Viewing Angle(Θ,Φ), refer to Fig9-2 as below :
(5) Definition of Response Time.(White – Black)
Date : 2008/12/8
AMPIRE CO., LTD.
13
8. INCOMING INSPECTION STANDARD FOR TFT-LCD PANEL
DEFECT TYPE
Note
LIMIT
φ<0.15mm
SPOT
FIBER
VISUAL
DEFECT
INTERNAL
POLARIZER
BUBBLE
Mura
0.15mm≦φ≦0.5mm
0.5mm<φ
0.03mm<W≦0.1mm,
L≦5mm
1.0mm<W, 1.5mm<L
φ<0.15mm
0.15mm≦φ≦0.5mm
0.5mm<φ
DARK DOT
ELECTRICAL
DEFECT
N=0
Ignore
N≦2
N=0
Note1
Note1
B Grade
C Area O Area
Total
C Area O Area
Total
Note3
N≦0
N≦2
N≦2
N≦2
N≦3
N≦5
Note2
N≦2
N≦3
N≦3
N≦3
N≦5
N≦8
N≦5
N≦6
N≦8
Note2
N≦1
pair
N≦1
pair
N≦1
pair
Note4
N≦4
TOTAL DOT
TWO ADJACENT DOT
N≦3
Note1
It’ OK if mura is slight visible through
6%ND filter
A Grade
BRIGHT DOT
Ignore
N≦4
N=0
N≦0
N≦1
pair
N≦1
pair
THREE OR MORE
NOT ALLOWED
ADJACENT DOT
LINE DEFECT
NOT ALLOWED
(1) One pixel consists of 3 sub-pixels, including R,G, and B dot.(Sub-pixel = Dot)
(2) LITTLE BRIGHT DOT ACCEPTITABLE UNDER 6 % ND-Filter
[Note1] W : Width[mm], L : Length[mm], N : Number, φ: Average Diameter
[Note2] Bright dot is defined through 6% transmission ND Filter as following.
Date : 2008/12/8
AMPIRE CO., LTD.
14
[Note3]
C Area: Center of display area
C Area: Outer of display area
[Note4]
Judge defect dot and adjacent dot as following. Allow below (as A, B, C and D status)
adjacent defect dots, including bright and dart adjacent dot. And they will be counted 2
defect dots in total quantity.
(1) The defects that are not defined above and considered to be problem shall be
reviewed and discussed by both parties.
(2) Defects on the Black Matrix, out of Display area, are not considered as a defect or
counted.
Date : 2008/12/8
AMPIRE CO., LTD.
15
9. RELIABILITY TEST CONDITIONS
ITEM
CONDITIONS
HIGH TEMPERATURE OPERATION
70℃ , 240Hrs
HIGH TEMPERATURE AND HIGH
HUMIDITY OPERATION
60℃ , 90%RH , 240Hrs
HIGH TEMPERATURE STORAGE
80℃ , 240Hrs
LOW TEMPERATURE OPERATION
-20℃ , 240Hrs
LOW TEMPERATURE STORAGE
-30℃ , 240Hrs
THERMAL SHOCK
-30℃(0.5Hr) ~80℃(0.5Hr)
200Cycle
9.1 OTHERS
AMIPRE will provide one year warrantee for all products and three months warrantee for
all repairing products.
Date : 2008/12/8
AMPIRE CO., LTD.
16
晶采 光 電 科技
10. OUTLINE DIMENSION
Date : 2008/12/8
AMPIRE CO., LTD.
17
晶采 光 電 科技
Date : 2008/12/8
AMPIRE CO., LTD.
18