SPECIFICATIONS FOR LCD MODULE CUSTOMER CUSTOMER PART NO. AMPIRE PART NO. APPROVED AM800480E3TMQW-01H BY DATE Approved For Specifications ;Approved For Specifications & Sample AMPIRE CO., LTD. Building D., 2F., No.88, Sec. 1, Sintai 5th Rd., Sijhih City, Taipei County 221, Taiwan (R.O.C.) 台北縣汐止市新台五路一段 88 號 2 樓(東方科學園區 D 棟) TEL:886-2-26967269 , FAX:886-2-86967196 or 26967270 APPROVED BY Date : 2008/06/04 CHECKED BY AMPIRE CO., LTD. ORGANIZED BY 1 RECORD Revision Date Page 2007/10/02 2007/11/20 2008/6/3 2008/6/4 9.10 17 -5-6 13 5 Date : 2008/06/04 OF REVISION Contents Editor New Release Change input signal drawing Add the Packing drawing New logo and correct the company address Add LED Backlight Specification Revise Little Bright Dot acceptable condition Add LED Backlight Life Time Donlin JACK AMPIRE CO., LTD. Edward Edward Edward Edward 2 1. INTRODUCTION Ampire Display Module AM800480E3 is a color active matrix TFT-LCD that uses amorphous silicon TFT as a switching device . This model is composed of a TFT-LCD panel ,This TFT-LCD has a high resolution (800(R.G.B) X 480) and can display up to 262,144 colors . 1-1. Features ● WVGA (16:9 diagonal) configuration ● Input interface voltage : 3.3V ● Data enable mode 1-2. Applications ● Portable TV ● Car user DVD ● Industrial application ● HMI (Human machine interface) 2. PHYSICAL SPECIFICATIONS Item Specifications unit Display resolution(dot) 800RGB (W) x 480(H) dots Active area 152.4 (W) x 91.44 (H) mm Pixel pitch 0.1905 (W) x 0.1905 (H) mm Color configuration R.G.B Vertical stripe Overall dimension 165.0(W)x104.0(H) mm Weight 123.0 ± 1.0 g Brightness 500 nit(typ) cd/m2 Contrast ratio 250 : 1 Backlight unit LED Display color 262,144 Date : 2008/06/04 AMPIRE CO., LTD. colors 3 3. ABSOLUTE MAX. RATINGS ITEM SYMBOL MIN MAX UNIT Vcc -0.5 5.0 V DCLK DE R0~R5 G0~G5 B0~b5 -0.5 VCC+0.5 V Operation Temperature Top -10 60 ℃ Storage Temperature Tstg -20 70 ℃ Power Supply Voltage for LCD Signal input voltage The following values are maximum operation conditions , If exceeded , it may cause faulty operation or damage Date : 2008/06/04 AMPIRE CO., LTD. 4 4. ELECTRICAL CHARACTERISTICS 4-1 TFT LCD Module voltage ITEM SYMBOL MIN TYP MAX UNIT Power Supply Voltage For LCD Vcc 3.0 3.3 4.0 V Power Supply Current For LCD Idd 200 250 300 mA Input Voltage Logic Input Threshold Voltage(High) Voltage Threshold Voltage(Low) VIN 0 - Vcc V VTH 3.0 - Vcc V VTL GND - 0.5 V Unit Condiction ILED =180mA,Ta=25℃ 4-2 Electrical characteristic of LED Back-light Paramenter Symbol Min. Typ. Max. LED voltage VLED -- 10.5 12.0 V LED forward current ILED -- 162 180 mA Ta=25℃ ILED -- 121 135 mA 10,000 -- -- hour Ta=60℃ ILED =180mA,Ta=25℃ Life Time Date : 2008/06/04 AMPIRE CO., LTD. 5 z The constant current source is needed for white LED back-light driving. When LCM is operated over 60℃ ambient temperature, the ILED of the LED back-light should be adjusted to 135mA max 4-3 Optical characteristic of the Back-light ITEM MIN TYP MAX UNIT Condition Bare Brightness 4650 --Cd/m2 ILED =180mA,Ta=25℃ AVG. X of 1931 C.I.E. 0.26 0.30 0.34 -ILED =180mA,Ta=25℃ AVG. Y of 1931 C.I.E. 0.27 0.31 0.35 -ILED =180mA,Ta=25℃ Brightness Uniformity 80 --% ILED =180mA,Ta=25℃ ( )For reference only. These data should be update according the prototype. Note1 : Measurement after 10 minutes from LED operating. Note2 : Measurement of the following 9 places on the display. W 5/6W 1/2W 1/6W Constant Current 180mA 1 L 3 5/6L A A 2 4 5 6 1/2L K DC Current meter 7 8 9 1/6L Note3: The Uniformity definition (Min Brightness / Max Brightness) x 100% Date : 2008/06/04 AMPIRE CO., LTD. 6 5. INTERFACE Pin no Symbol 1 GND 2 GND 3 AGING (NC) 4 VCC 5 VCC 6 VCC 7 VCC 8 HS (NC) 9 DE 10 GND 11 GND 12 GND 13 B5 14 B4 15 B3 16 GND 17 B2 18 B1 19 B0 20 GND 21 G5 22 G4 23 G3 24 GND 25 G2 26 G1 27 G0 28 GND 29 R5 30 R4 31 R3 32 GND 33 R2 34 R1 35 R0 36 GND 37 GND 38 DCLK 39 GND 40 GND Date : 2008/06/04 Function Ground Ground Aging test mode, No Connection. Power supply (3.3V) Power supply (3.3V) Power supply (3.3V) Power supply (3.3V) HSYNC for test mode, NO Connection. Data Enable Timing Signal Ground Ground Ground Blue data (MSB) Blue data Blue data Ground Blue data Blue data Blue data (LSB) Ground Green data (MSB) Green data Green data Ground Green data Green data Green data (LSB) Ground Red data (MSB) Red data Red data Ground Red data Red data Red data (LSB) Ground Ground Data Clock Ground Ground AMPIRE CO., LTD. 7 6. OPTICAL CHARACTERISTICS Item Symbol Response Time Tr +Tf Contrast ratio Viewing Angle CR Vertical Θ Horizontal Φ Luminance L Red Color chromaticity Green Blue White Rx Ry Gx Gy Bx By Wx Wy Conditon Θ=Φ=0° Min. Typ. Max. Unit Note - 20 30 ms (1) 250 120 CR≧10 (5) 140 Θ=Φ=0° Θ=Φ=0° (2)(3) 500 (3)(4) 0.541 0.581 0.621 0.321 0.361 0.401 0.314 0.354 0.394 0.524 0.564 0.604 0.108 0.148 0.188 0.084 0.124 0.164 0.277 0.317 0.357 0.315 0.355 0.395 (3) NOTE : ● These items are measured by BM-7(TOPCON) in the dark room (no ambient light) ● Brightness conditions : IL=180mA. (1) Definition of Response Time (White-Black) (2) Definition of Contrast Ratio Measure contrast ratio on the below 5 points(refer to figurel,#1~#5point) and take the average value Contrast ratio is calculated with the following formula : Contrast Ratio(CR)=(White)Luminance of ON ÷ (Black)Luminance of OFF Date : 2008/06/04 AMPIRE CO., LTD. 8 (3) Definition of Luminance : Measure white luminance on the same 5 points and take the average value (1) Definition of Luminance Uniformity : Measured Maximum luminance[L(MAX)] and Minimum luminance[L(MIN)] on the 5 points Luminance Uniformity is calculated with the following formula : ΔL =[ L(MAX) / L(MIN) –1 ] X 100 (2) Definition of Viewing Angle Φ =(Θx+)+(Θx-) Date : 2008/06/04 Θ =(Θy+)+(Θy-) AMPIRE CO., LTD. 9 7. INPUT SIGNAL ( DE ONLY MODE ) Timing Characteristics z This module is operated by DE only mode Date : 2008/06/04 AMPIRE CO., LTD. 10 Date : 2008/06/04 AMPIRE CO., LTD. 11 8. QUALITY AND RELIABILITY 8.1 TEST CONDITIONS Tests should be conducted under the following conditions : Ambient temperature : 25 ± 5°C Humidity : 60 ± 25% RH. 8.2 SAMPLING PLAN Sampling method shall be in accordance with MIL-STD-105E , level II, normal single sampling plan . 8.3 ACCEPTABLE QUALITY LEVEL A major defect is defined as one that could cause failure to or materially reduce the usability of the unit for its intended purpose. A minor defect is one that does not materially reduce the usability of the unit for its intended purpose or is an infringement from established standards and has no significant bearing on its effective use or operation. 8.4 APPEARANCE An appearance test should be conducted by human sight at approximately 30 cm distance from the LCD module under florescent light. The inspection area of LCD panel shall be within the range of following limits. Date : 2008/06/04 AMPIRE CO., LTD. 12 8.5 INCOMING INSPECTION STANDARD FOR TFT-LCD PANEL Note DEFECT TYPE LIMIT φ<0.15mm 0.15mm≦φ≦0.5mm SPOT FIBER VISUAL DEFECT INTERNAL POLARIZER BUBBLE 0.5mm<φ 0.03mm<W≦0.1mm, L≦5mm 1.0mm<W, 1.5mm<L φ<0.15mm 0.15mm≦φ≦0.5mm 0.5mm<φ N≦3 N=0 Ignore N≦2 N=0 Note1 Note1 Note1 It’ OK if mura is slight visible through 6%ND filter Mura A Grade BRIGHT DOT DARK DOT B Grade C Area O Area Total C Area O Area Total Note3 N≦0 N≦2 N≦2 N≦2 N≦3 N≦5 Note2 N≦2 N≦3 N≦3 N≦3 N≦5 N≦8 N≦5 N≦6 N≦8 Note2 N≦1 pair N≦1 pair N≦1 pair Note4 N≦4 TOTAL DOT ELECTRICAL DEFECT Ignore N≦4 N=0 TWO ADJACENT DOT N≦0 N≦1 pair N≦1 pair THREE OR MORE NOT ALLOWED ADJACENT DOT LINE DEFECT NOT ALLOWED (1) One pixel consists of 3 sub-pixels, including R,G, and B dot.(Sub-pixel = Dot) (2) LITTLE BRIGHT DOT acceptable under 6% ND-Filter [Note1] W : Width[mm], L : Length[mm], N : Number, φ: Average Diameter [Note2] Bright dot is defined through 5% transmission ND Filter as following. Date : 2008/06/04 AMPIRE CO., LTD. 13 [Note3] C Area: Center of display area C Area: Outer of display area [Note4] Judge defect dot and adjacent dot as following. Allow below (as A, B, C and D status) adjacent defect dots, including bright and dart adjacent dot. And they will be counted 2 defect dots in total quantity. (1) The defects that are not defined above and considered to be problem shall be reviewed and discussed by both parties. (2) Defects on the Black Matrix, out of Display area, are not considered as a defect or counted. Date : 2008/06/04 AMPIRE CO., LTD. 14 8.6 RELIABILITY TEST CONDITIONS ITEM HIGH TEMPERATURE OPERATION CONDITIONS 60℃ , 240Hrs HIGH TEMPERATURE AND HIGH HUMIDITY OPERATION 40℃ , 90%RH , 240Hrs HIGH TEMPERATURE AND HIGH HUMIDITY STORAGE 60℃ , 90%RH , 48 Hrs HIGH TEMPERATURE STORAGE 70℃ , 240Hrs LOW TEMPERATURE OPERATION -10℃ , 240Hrs LOW TEMPERATURE STORAGE -20℃ , 240Hrs THERMAL SHOCK (No operation) ESD NOTE -20℃(0.5Hr) ~60℃(0.5Hr) 200Cycle ±8kV&±15kV air & contact test (1) 0Ω,±200V contact test (2) NOTE : Measure point : (1) LCD glass and bezel (2) IF connector pins Date : 2008/06/04 AMPIRE CO., LTD. 15 9. USE PRECAUTIONS 9-1 Handling precautions (1) The polarizing plate may break easily so be careful when handling it. Do not touch, press or rub it with a hard-material tool like tweezers. (2) Do not touch the polarizing plate surface with bare hands so as not to make it dirty. If the surface or other related part of the polarizing plate is dirty, soak a soft cotton cloth or chamois leather in benzine and wipe off with it. Do not use chemical liquids such as acetone, toluene and isopropyl alcohol. Failure to do so may bring chemical reaction phenomena and deteriorations. (3) Remove any spit or water immediately. If it is left for hours, the suffered part may deform or decolorize. (4) If the LCD element breaks and any LC stuff leaks, do not suck or lick it. Also if LC stuff is stuck on your skin or clothing, wash thoroughly with soap and water immediately. 9-2 Installing precautions (1) The PCB has many ICs that may be damaged easily by static electricity. To prevent breaking by static electricity from the human body and clothing, earth the human body properly using the high resistance and discharge static electricity during the operation. In this case, however, the resistance value should be approx. 1MΩ and the resistance should be placed near the human body rather than the ground surface. When the indoor space is dry, static electricity may occur easily so be careful. We recommend the indoor space should be kept with humidity of 60% or more. When a soldering iron or other similar tool is used for assembly, be sure to earth it. (2) When installing the module and ICs, do not bend or twist them. Failure to do so may crack LC element and cause circuit failure. (3) To protect LC element, especially polarizing plate, use a transparent protective plate (e.g., acrylic plate, glass etc) for the product case. (4) Do not use an adhesive like a both-side adhesive tape to make LCD surface (polarizing plate) and product case stick together. Failure to do so may cause the polarizing plate to peel off 9-3 Storage precautions (1) Avoid a high temperature and humidity area. Keep the temperature between 0°C and 35°C and also the humidity under 60%. (2) Choose the dark spaces where the product is not exposed to direct sunlight or fluorescent light. (3) Store the products as they are put in the boxes provided from us or in the same conditions as we recommend. Date : 2008/06/04 AMPIRE CO., LTD. 16 9-4 Operating precautions (1) Do not boost the applied drive voltage abnormally. Failure to do so may break ICs. When applying power voltage, check the electrical features beforehand and be careful. Always turn off the power to the LC module controller before removing or inserting the LC module input connector. If the input connector is removed or inserted while the power is turned on, the LC module internal circuit may break. (2) The display response may be late if the operating temperature is under the normal standard, and the display may be out of order if it is above the normal standard. But this is not a failure; this will be restored if it is within the normal standard. (3) The LCD contrast varies depending on the visual angle, ambient temperature, power voltage etc. Obtain the optimum contrast by adjusting the LC dive voltage. (4) When carrying out the test, do not take the module out of the low-temperature space suddenly. Failure to do so will cause the module condensing, leading to malfunctions. (5) Make certain that each signal noise level is within the standard (L level: 0.2Vdd or less and H level: 0.8Vdd or more) even if the module has functioned properly. If it is beyond the standard, the module may often malfunction. In addition, always connect the module when making noise level measurements. (6) The CMOS ICs are incorporated in the module and the pull-up and pull-down function is not adopted for the input so avoid putting the input signal open while the power is ON. (7) The characteristic of the semiconductor element changes when it is exposed to light emissions, therefore ICs on the LCD may malfunction if they receive light emissions. To prevent these malfunctions, design and assemble ICs so that they are shielded from light emissions. (8) Crosstalk occurs because of characteristics of the LCD. In general, crosstalk occurs when the regularized display is maintained. Also, crosstalk is affected by the LC drive voltage. Design the contents of the display, considering crosstalk. 9-5 Other (1) Do not disassemble or take the LC module into pieces. The LC modules once disassembled or taken into pieces are not the guarantee articles. (2) The residual image may exist if the same display pattern is shown for hours. This residual image, however, disappears when another display pattern is shown or the drive is interrupted and left for a while. But this is not a problem on reliability. (3) AMIPRE will provide one year warrantee for all products and three months warrantee for all repairing products. Date : 2008/06/04 AMPIRE CO., LTD. 17 1層15x2 LCM = 30pcs LCM 1箱2層 30x2= 60pcs LCM 增加適用機種 適用機種: 480234C 系列 480234G-CW/G-CW-T 系列 480234G-QW 系列 480234G1-CW 系列 800480E2/E2-T 系列 800480E3/E3-T 系列 10. Packing Date : 2008/06/04 Drawing AMPIRE CO., LTD. 18 晶采 光 電 科技 11. OUTLINE DIMENSION Date : 2008/06/04 AMPIRE CO., LTD. 19 晶采 光 電 科技 Date : 2008/06/04 AMPIRE CO., LTD. 20