SPECIFICATIONS FOR LCD MODULE CUSTOMER CUSTOMER PART NO. AM-800600LTNQW-A0H AMPIRE PART NO. APPROVED BY DATE Approved For Specifications ; Approved For Specifications & Sample AMPIRE CO., LTD. 2F., No.88, Sec. 1, Sintai 5th Rd., Sijhih City, Taipei County 221, Taiwan (R.O.C.)台北縣汐止市新台五路一段 88 號 2 樓(東方科學園區 D 棟) TEL:886-2-26967269 , FAX:886-2-26967196 or 26967270 APPROVED BY Date : 2009/10/14 CHECKED BY AMPIRE CO., LTD. ORGANIZED BY 1 RECORD Revision Date Page 2009/07/22 2009/08/12 2009/10/14 6 4 2009/10/14 7 Date : 2009/10/14 OF REVISION Contents New Release Revise Backlight Driving Circuit Revise the optical characteristics (response time, chromaticity and uniformity). Revise the electrical characteristics (VLEDA-LEDK=19.2V). AMPIRE CO., LTD. Editor John Edward Emil Emil 2 1. INSTRUCTION Ampire 10.4” Display Module is a color active matrix TFT-LCD that uses amorphous silicon TFT as a switching device . This model is composed of a TFT-LCD panel and LED Backlight . This TFT-LCD has a high resolution (800(R.G.B) X 600) and can display up to 262,144 colors. 1.1 Features (1) Construction : a-Si TFT-LCD with driving system, White LED Backlight. (2) LCD type : Transmissive , Normally White (3) Number of the Colors : 262K colors (R,G,B 6 bit digital each) (4) LVDS Interface. (5) LCD Power Supply Voltage : 3.3V (6) Build-in LED Driver IC (VLED=5V). Note* Note* : When LED_EN(Pin18) is Low Voltage, ADJ(Pin20) must be Low voltage to prevent a short circuit. Or you can set LED_EN(Pin18) always High voltage, just control brightness by ADJ(Pin20). 2. PHYSICAL SPECIFICATIONS Item Specifications unit Display resolution(dot) 800RGB (W) x 600(H) dots Active area 211.2 (W) x 158.4(H) mm Pixel pitch 264 (W) x 264 (H) um Color configuration R.G.B -stripe Overall dimension 236.0(W)x176.9(H)x10.96(D) mm Weight 312 g Brightness 300 cd/m2 Backlight unit LED Display color 262,144 Date : 2009/10/14 AMPIRE CO., LTD. colors 3 3. ABSOLUTE MAXIMUM RATINGS Item Symbol Min. Max. Unit VCC -0.3 6 V VLED -0.3 6 V Operation -20 70 ℃ Storage -30 80 ℃ Power Voltage Temperature Range (1). All of the voltages listed above are with respective to GND =0V (2). Device is subject to be damaged permanently if stresses beyond those absolute maximum ratings listed above. 4. OPTICAL CHARACTERISTICS Item Symbol Response Time Contrast ratio Typ. Max. Unit Note - 25 40 ms (1) 300 400 - - (2)(3) 35 45 - 55 65 - 55 65 - Deg. (5) ΘR 55 65 - L 210 300 - cd/m2 (3) 70 80 - % (4) 0.259 0.284 0.309 0.334 0.359 0.384 - CR Vertical Viewing Angle Min. Tr +Tf Horizontal Luminance Θ=Φ=0° ΘT ΘB ΘL Luminance Uniformity ΔL Chromaticity Wx Wy White Condition CR≧10 Θ=Φ=0° NOTE : ● These items are measured by BM-5A(TOPCON) or CA-1000(MINOLTA) in the dark room (no ambient light) After 5 minutes operation, the optical properties are measured at the center point of the LCD screen. (1) Definition of Response Time (White-Black) Date : 2009/10/14 AMPIRE CO., LTD. 4 (2) Definition of Contrast Ratio Contrast ratio is calculated with the following formula : Contrast Ratio(CR)=(White)Luminance of ON ÷ (Black)Luminance of OFF (3) Definition of Luminance: Measure the luminance of white state at center point. (4)Definition of Luminance Uniformity : Measured Maximum luminance [L(MAX)] and Minimum luminance[L(MIN)] on the 9 points. Luminance Uniformity is calculated with the following formula: ΔL =[ L(MIN) / L (MAX) ] X 100% (5)Definition of Viewing Angle Date : 2009/10/14 AMPIRE CO., LTD. 5 5. ELECTRICAL CHARACTERISTICS 5.1 TFT LCD Module voltage SYMBO ITEM L Power Voltage For LCD VCC Digital Supply current IVCC Consumption VIH Logic Input Voltage VIL MIN TYP MAX UNIT 3.0 3.3 3.6 V 290 VCC*0.7 -- VCC V 0 -- VCC*0.3 V 5.2 Backlight Driving Circuit ITEM SYMBOL LED Driver VLED Power Voltage LED Current ILED LED Life Time(MTBF) LED Driver Power Current Date : 2009/10/14 mA ILED(VLED=5V) NOTE Black Pattern MIN TYP MAX UNIT 3.3 5 5.5 V --- 83 30k --- mA Hr Note1 Note2 - 287 -- mA Ta=25℃ AMPIRE CO., LTD. NOTE 6 Note 1 : There are 6 Groups LED shown as below , VLEDA-LEDK=19.2V ,Ta=25℃ LED_A 20mA 120mA 83mA 13.8mA LED_K Note2 : Condition: Ta=25℃, continuous lighting Life time is estimated data. Definitions of failure: 1. LCM brightness becomes half of the minimum value. 2. LED doesn’t light normally. 5.3 PWM Dimming Control F=100~200Hz 3.3V 0V Date : 2009/10/14 AMPIRE CO., LTD. 7 6. INTERFACE LVDS INTERFACE CN: HRS DF14A-20P-1.25H Pin No. Symbol I/O 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 VDD VDD GND GND IN0IN0+ GND IN1IN1+ GND IN2IN2+ GND CLKCLK+ GND VLED LED_EN GND ADJ P P P P I I P I I P I I P I I P P I I P *Note: Description Power supply for digital circuit (3.3V) Power supply for digital circuit (3.3V) Power ground Power ground LVDS receiver negative signal channel 0 LVDS receiver positive signal channel 0 Power ground LVDS receiver negative signal channel 1 LVDS receiver positive signal channel 1 Power ground LVDS receiver negative signal channel 2 LVDS receiver positive signal channel 2 Power ground LVDS receiver negative signal clock LVDS receiver positive signal clock Power ground Voltage for LED circuit (5.0V) LED BLU ON/OFF Power ground Adjust the LED brightness by PWM Note *Note *Note When LED_EN(Pin18) is Low Voltage, ADJ(Pin20) must be Low voltage to prevent a short circuit. Or you colud set LED_EN(Pin18) always High voltage , just control brightness by ADJ(Pin20). Date : 2009/10/14 AMPIRE CO., LTD. 8 7. AC Timing characteristic 7-1 Timing Specification. Date : 2009/10/14 AMPIRE CO., LTD. 9 7-2 Power ON/OFF Sequence Date : 2009/10/14 AMPIRE CO., LTD. 10 8. QUALITY AND RELIABILITY 8.1 TEST CONDITIONS Tests should be conducted under the following conditions : Ambient temperature : 25 ± 5°C Humidity : 60 ± 25% RH. 8.2 SAMPLING PLAN Sampling method shall be in accordance with MIL-STD-105E , level II, normal single sampling plan . 8.3 ACCEPTABLE QUALITY LEVEL A major defect is defined as one that could cause failure to or materially reduce the usability of the unit for its intended purpose. A minor defect is one that does not materially reduce the usability of the unit for its intended purpose or is an infringement from established standards and has no significant bearing on its effective use or operation. 8.4 APPEARANCE An appearance test should be conducted by human sight at approximately 30 cm distance from the LCD module under florescent light. The inspection area of LCD panel shall be within the range of following limits. Date : 2009/10/14 AMPIRE CO., LTD. 11 8.5 INCOMING INSPECTION STANDARD FOR DEFECT TYPE TFT-LCD PANEL Note LIMIT φ<0.15mm SPOT FIBER VISUAL DEFECT INTERNAL POLARIZER BUBBLE Mura 0.15mm≦φ≦0.5mm 0.5mm<φ 0.03mm<W≦0.1mm, L≦ 5mm 1.0mm<W, 1.5mm<L φ<0.15mm 0.15mm≦φ≦0.5mm 0.5mm<φ DARK DOT ELECTRICAL DEFECT N=0 N≦3 N=0 Ignore N≦2 N=0 Note1 Note1 B Grade C Area O Area Total C Area O Area Total Note3 N≦0 N≦2 N≦2 N≦2 N≦3 N≦5 Note2 N≦2 N≦3 N≦3 N≦3 N≦5 N≦8 N≦5 N≦6 N≦8 Note2 N≦1 pair N≦1 pair N≦1 pair Note4 N≦4 TOTAL DOT TWO ADJACENT DOT Note1 It’ OK if mura is slight visible through 6%ND filter A Grade BRIGHT DOT Ignore N≦4 N≦0 N≦1 pair N≦1 pair THREE OR MORE NOT ALLOWED ADJACENT DOT LINE DEFECT NOT ALLOWED (1) One pixel consists of 3 sub-pixels, including R,G, and B dot.(Sub-pixel = Dot) (2) LITTLE BRIGHT DOT ACCEPTABLE UNDER 6 % ND-Filter [Note1] W : Width[mm], L : Length[mm], N : Number, φ: Average Diameter [Note2] Bright dot is defined through 6% transmission ND Filter as following. Date : 2009/10/14 AMPIRE CO., LTD. 12 [Note3] C Area: Center of display area C Area: Outer of display area [Note4] Judge defect dot and adjacent dot as following. Allow below (as A, B, C and D status) adjacent defect dots, including bright and dart adjacent dot. And they will be counted 2 defect dots in total quantity. (1) The defects that are not defined above and considered to be problem shall be reviewed and discussed by both parties. (2) Defects on the Black Matrix, out of Display area, are not considered as a defect or counted. Date : 2009/10/14 AMPIRE CO., LTD. 13 8.6 Reliability Test Test Item Test Conditions High Temperature Operation 70±3°C , t=96 hrs Low Temperature Operation -20±3°C , t=96 hrs High Temperature Storage 80±3°C , t=96 hrs Low Temperature Storage Thermal Shock Test Humidity Test -30±3°C , t=96 hrs -20°C ~ 25°C ~ 70°C 30 m in. 5 min. 30 min. ( 1 cycle ) Total 5 cycle 60 °C, Humidity 90%, 96 hrs Sweep frequency : 10 ~ 55 ~ 10 Hz/1min Amplitude : 0.75mm Vibration Test (Packing) Test direction : X.Y.Z/3 axis Duration : 30min/each axis Note 1 : Condensation of water is not permitted on the module. Note 2 : The module should be inspected after 1 hour storage in normal conditions (15-35°C , 45-65%RH). Definitions of life end point : z z z z Note 1,2 1,2 1,2 1,2 2 Current drain should be smaller than the specific value. Function of the module should be maintained. Appearance and display quality should not have degraded noticeably. Contrast ratio should be greater than 50% of the initial value. Date : 2009/10/14 AMPIRE CO., LTD. 14 9. USE PRECAUTIONS 9.1 Handling precautions 1) The polarizing plate may break easily so be careful when handling it. Do not touch, press or rub it with a hard-material tool like tweezers. 2) Do not touch the polarizing plate surface with bare hands so as not to make it dirty. If the surface or other related part of the polarizing plate is dirty, soak a soft cotton cloth or chamois leather in benzine and wipe off with it. Do not use chemical liquids such as acetone, toluene and isopropyl alcohol. Failure to do so may bring chemical reaction phenomena and deteriorations. 3) Remove any spit or water immediately. If it is left for hours, the suffered part may deform or decolorize. 4) If the LCD element breaks and any LC stuff leaks, do not suck or lick it. Also if LC stuff is stuck on your skin or clothing, wash thoroughly with soap and water immediately. 9.2 Installing precautions 1) The PCB has many ICs that may be damaged easily by static electricity. To prevent breaking by static electricity from the human body and clothing, earth the human body properly using the high resistance and discharge static electricity during the operation. In this case, however, the resistance value should be approx. 1MΩ and the resistance should be placed near the human body rather than the ground surface. When the indoor space is dry, static electricity may occur easily so be careful. We recommend the indoor space should be kept with humidity of 60% or more. When a soldering iron or other similar tool is used for assembly, be sure to earth it. 2) When installing the module and ICs, do not bend or twist them. Failure to do so may crack LC element and cause circuit failure. 3) To protect LC element, especially polarizing plate, use a transparent protective plate (e.g., acrylic plate, glass etc) for the product case. 4) Do not use an adhesive like a both-side adhesive tape to make LCD surface (polarizing plate) and product case stick together. Failure to do so may cause the polarizing plate to peel off. 9.3 Storage precautions 1) Avoid a high temperature and humidity area. Keep the temperature between 0°C and 35°C and also the humidity under 60%. 2) Choose the dark spaces where the product is not exposed to direct sunlight or fluorescent light. 3) Store the products as they are put in the boxes provided from us or in the same conditions as we recommend. Date : 2009/10/14 AMPIRE CO., LTD. 15 9.4 Operating precautions 1) Do not boost the applied drive voltage abnormally. Failure to do so may break ICs. When applying power voltage, check the electrical features beforehand and be careful. Always turn off the power to the LC module controller before removing or inserting the LC module input connector. If the input connector is removed or inserted while the power is turned on, the LC module internal circuit may break. 2) The display response may be late if the operating temperature is under the normal standard, and the display may be out of order if it is above the normal standard. But this is not a failure; this will be restored if it is within the normal standard. 3) The LCD contrast varies depending on the visual angle, ambient temperature, power voltage etc. Obtain the optimum contrast by adjusting the LC dive voltage. 4) When carrying out the test, do not take the module out of the low-temperature space suddenly. Failure to do so will cause the module condensing, leading to malfunctions. 5) Make certain that each signal noise level is within the standard (L level: 0.2Vdd or less and H level: 0.8Vdd or more) even if the module has functioned properly. If it is beyond the standard, the module may often malfunction. In addition, always connect the module when making noise level measurements. 6) The CMOS ICs are incorporated in the module and the pull-up and pull-down function is not adopted for the input so avoid putting the input signal open while the power is ON. 7) The characteristic of the semiconductor element changes when it is exposed to light emissions, therefore ICs on the LCD may malfunction if they receive light emissions. To prevent these malfunctions, design and assemble ICs so that they are shielded from light emissions. 8) Crosstalk occurs because of characteristics of the LCD. In general, crosstalk occurs when the regularized display is maintained. Also, crosstalk is affected by the LC drive voltage. Design the contents of the display, considering crosstalk. 9.5 Other 1) Do not disassemble or take the LC module into pieces. The LC modules once disassembled or taken into pieces are not the guarantee articles. 2) The residual image may exist if the same display pattern is shown for hours. This residual image, however, disappears when another display pattern is shown or the drive is interrupted and left for a while. But this is not a problem on reliability. 3) AMIPRE will provide one year warranty for all products and three months warrantee for all repairing products. Date : 2009/10/14 AMPIRE CO., LTD. 16 10. OUTLINE DIMENSION Date : 2009/10/14 AMPIRE CO., LTD. 17 Date : 2009/10/14 AMPIRE CO., LTD. 18