BP18-12 - BB

Valve Regulated Lead-Acid Rechargeable Battery
BP18-12
The battery is constructed by plates,
separators, safety valves and container.
Since the electrolyte is held by a glassmat separator and plates, the battery
can be used in any direction and position
without leakage.
PERFORMANCE SPECIFICATIONS
Nominal Voltage(V)..........................................................................................................................12 volts(6cells in series)
Nominal Capacity(AH)
20 hour rate F.V.(1.75V/cell) (900mA to 10.50volts) ........................................................................................18.0A.H.
10 hour rate F.V.(1.75V/cell) (1710mA to10.50volts) .......................................................................................17.1A.H.
5 hour rate F.V.(1.75V/cell) (3060mA to 10.50volts) ........................................................................................15.3A.H.
1 hour rate F.V.(1.55V/cell) (10800mA to 9.30volts)..........................................................................................10.8A.H.
Approximate Weight.....................................................................................................................................6150g(13.56lbs.)
Terminal
Standard.................................................................................................................................................................Type B1
Optional..............................................................................................................................................................Type T2,I1
Internal Resistance (Fully Charged Battery).............................................................................................................<16m
Maximum Discharge Current For 5 sec.(A)..................................................................................................................270A
Maximum Charge Current(A)..........................................................................................................................................5.4A
Ambient Temperature
Charge............................................................................................................................................0oC(32oF)~40oC(104oF)
Discharge.....................................................................................................................................-20oC(-4oF)~50oC(122oF)
Storage.........................................................................................................................................-20oC(-4oF)~40oC(104oF)
Vibration test:
Frequency: 16.7HZ
Amplitude: 4mm
Vibrate the battery horizontally or vertically for 60 minutes. The battery have no abnormality.
Case..................................................................................................................................................................................ABS
Dimension(mm/inch)
Length
1.5mm.....................................................................................................................................181/7.13
Width
1.5mm.......................................................................................................................................76/2.99
Container Height
1.5mm.....................................................................................................................................166/6.54
Total Height
1.5mm.....................................................................................................................................166/6.54
Application..........................................UPS, Fishing Lights, Emergency Lights, Lawn Mowers, Video Camcorders(VCR).
BP18-12 Battery discharge characteristics (25°C/77°F)
Battery Charging Characteristics
(Typical example of the charge characteristics for the standby use)
Terminal Voltage(V)
11.0
3.06A 1.71A
0.90A
4.5A
10.0
10.8A
9.0
8.0
54A 36A
7.0
1
2
3
5
10
0.21
15.0
120
0.18
14.0
100
0.15
13.0
80
60
40
0.12
0.09
0.06
20
0.03
0
0
Charge voltage(V)
Charge volume(%)
12.0
140
Charge current(CA)
13.0
Charge voltage
C ha rg e
1 Discharge
100 %(0.05CA x 20h)
50 %(0.05CA x 10h)
2 Constant voltage charging
Charge voltage:2.275V/cell
Charge current:0.1CA
3 Temperature:20°C(68°F)
12.0
11.0
10.0
Charge current
18A
20
vo lu m e
30
60
2
3
5
10
20
0
0
30
5
10
15
20
25
Charge time (hr)
Hr
Min
Discharge time
Effect of Temperature on Long Term Float Life
Charging Procedure
For standby
power Source
For
cycle service
Charging
method
Constant
voltage &
Constant
current
charging
(with current
restriction)
Temperature
Max. charging
Charging
compensation
current
Voltage
coefficient of
(CA)
at 20OC
voltage
(V/cell) charging
O
(mV/ C/cell)
2.25~2.30
-3
Charging time
O
0.1CA, 20 C
(h)
100%
discharge
24
0.3
Temp
O
( C)
50%
discharge
20
0~40
O
(32~104 F)
2.40~2.50
-4
0.3
16
6
5
4
Life expectancy(year)
Application
10
8
Charging voltage :
2.275V/cell
3
2
1
10
O
0.5
O
*Temperature compensation of charging voltage is not needed, when using the batteries within 5 C to 35 C range.
20
68
30
86
50 oC
122 oF
40
104
Battery temperature
TERMINAL TYPE
OUTER DIMENSIONS
Constant power discharge characteristics at 25 oC/77 oF
mm(inch)
Terminal T2
Terminal B1
12.0(0.47)
Discharge time
3.4(0.13)
2.0(0.08)
6.35(0.25)
7.85(0.31)
[M5 BOLT & NUT]
Terminal I1
2.0(0.08)
5Min
10Min
15Min
30Min
1Hr
3Hr
5Hr
10Hr
20Hr
Battery output power(W)
0.8(0.03)
5.5(0.22)
11.0(0.43)
5.0(0.20)
Final Voltage
10.80V
614.6
452.5
362.6
215.7
123.73
49.55
34.17
19.09
9.98
10.50V
711.4
490.2
379.3
223.9
127.44
50.54
34.68
19.38
10.20
10.20V
755.9
507.8
391.0
229.1
129.73
51.00
34.87
19.48
10.25
9.90V
789.8
520.0
400.0
232.3
131.29
51.35
34.99
19.54
10.27
9.60V
816.0
530.4
408.0
234.6
132.60
51.66
35.10
19.54
10.27
M5
TERMINAL POSITION
[M5 BOLT & NUT]
USA:
B&B BATTERY(USA) INC.
6415 RANDOLPH ST.COMMERCE,
CA,90040 U.S.A.
TEL:1-323-278-1900.1-800-278-8599
FAX:1-323-278-1268
E-Mail:[email protected]
EUROPE:
B&B BATTERY(EUROPE) B.V.
3 WIJNGAARDVELD, 9300 AALST,BELGIUM
TEL:(00)32-53781567
FAX:(00)32-53781567
E-Mail:[email protected]
RAOPING, GUANG DONG,CHINA,515700
TEL:86-768-7601001-2
FAX:86-768-7601469
E-Mail:[email protected]
JAPAN:
B&B BATTERY(JAPAN) CO., LTD.
1375-11 NARAHARA-MACHI,HACHIOJI,
TOKYO 193-0803,JAPAN.
TEL:81-426-25-6375
FAX:81-426-25-6375
E-Mail:[email protected]
HONG KONG:
NATIONAL TRADING LTD.
TEL:852-2301-3800
FAX:852-2739-1182
E-Mail:[email protected]
TAIWAN:
B.B. BATTERY(TAIWAN) CO., LTD.
TEL:886-6-502-5150
FAX:886-6-589-8087
E-Mail:[email protected]
CHINA FACTORY:
REV. Jul. 2005