Valve Regulated Lead-Acid Rechargeable Battery BP18-12 The battery is constructed by plates, separators, safety valves and container. Since the electrolyte is held by a glassmat separator and plates, the battery can be used in any direction and position without leakage. PERFORMANCE SPECIFICATIONS Nominal Voltage(V)..........................................................................................................................12 volts(6cells in series) Nominal Capacity(AH) 20 hour rate F.V.(1.75V/cell) (900mA to 10.50volts) ........................................................................................18.0A.H. 10 hour rate F.V.(1.75V/cell) (1710mA to10.50volts) .......................................................................................17.1A.H. 5 hour rate F.V.(1.75V/cell) (3060mA to 10.50volts) ........................................................................................15.3A.H. 1 hour rate F.V.(1.55V/cell) (10800mA to 9.30volts)..........................................................................................10.8A.H. Approximate Weight.....................................................................................................................................6150g(13.56lbs.) Terminal Standard.................................................................................................................................................................Type B1 Optional..............................................................................................................................................................Type T2,I1 Internal Resistance (Fully Charged Battery).............................................................................................................<16m Maximum Discharge Current For 5 sec.(A)..................................................................................................................270A Maximum Charge Current(A)..........................................................................................................................................5.4A Ambient Temperature Charge............................................................................................................................................0oC(32oF)~40oC(104oF) Discharge.....................................................................................................................................-20oC(-4oF)~50oC(122oF) Storage.........................................................................................................................................-20oC(-4oF)~40oC(104oF) Vibration test: Frequency: 16.7HZ Amplitude: 4mm Vibrate the battery horizontally or vertically for 60 minutes. The battery have no abnormality. Case..................................................................................................................................................................................ABS Dimension(mm/inch) Length 1.5mm.....................................................................................................................................181/7.13 Width 1.5mm.......................................................................................................................................76/2.99 Container Height 1.5mm.....................................................................................................................................166/6.54 Total Height 1.5mm.....................................................................................................................................166/6.54 Application..........................................UPS, Fishing Lights, Emergency Lights, Lawn Mowers, Video Camcorders(VCR). BP18-12 Battery discharge characteristics (25°C/77°F) Battery Charging Characteristics (Typical example of the charge characteristics for the standby use) Terminal Voltage(V) 11.0 3.06A 1.71A 0.90A 4.5A 10.0 10.8A 9.0 8.0 54A 36A 7.0 1 2 3 5 10 0.21 15.0 120 0.18 14.0 100 0.15 13.0 80 60 40 0.12 0.09 0.06 20 0.03 0 0 Charge voltage(V) Charge volume(%) 12.0 140 Charge current(CA) 13.0 Charge voltage C ha rg e 1 Discharge 100 %(0.05CA x 20h) 50 %(0.05CA x 10h) 2 Constant voltage charging Charge voltage:2.275V/cell Charge current:0.1CA 3 Temperature:20°C(68°F) 12.0 11.0 10.0 Charge current 18A 20 vo lu m e 30 60 2 3 5 10 20 0 0 30 5 10 15 20 25 Charge time (hr) Hr Min Discharge time Effect of Temperature on Long Term Float Life Charging Procedure For standby power Source For cycle service Charging method Constant voltage & Constant current charging (with current restriction) Temperature Max. charging Charging compensation current Voltage coefficient of (CA) at 20OC voltage (V/cell) charging O (mV/ C/cell) 2.25~2.30 -3 Charging time O 0.1CA, 20 C (h) 100% discharge 24 0.3 Temp O ( C) 50% discharge 20 0~40 O (32~104 F) 2.40~2.50 -4 0.3 16 6 5 4 Life expectancy(year) Application 10 8 Charging voltage : 2.275V/cell 3 2 1 10 O 0.5 O *Temperature compensation of charging voltage is not needed, when using the batteries within 5 C to 35 C range. 20 68 30 86 50 oC 122 oF 40 104 Battery temperature TERMINAL TYPE OUTER DIMENSIONS Constant power discharge characteristics at 25 oC/77 oF mm(inch) Terminal T2 Terminal B1 12.0(0.47) Discharge time 3.4(0.13) 2.0(0.08) 6.35(0.25) 7.85(0.31) [M5 BOLT & NUT] Terminal I1 2.0(0.08) 5Min 10Min 15Min 30Min 1Hr 3Hr 5Hr 10Hr 20Hr Battery output power(W) 0.8(0.03) 5.5(0.22) 11.0(0.43) 5.0(0.20) Final Voltage 10.80V 614.6 452.5 362.6 215.7 123.73 49.55 34.17 19.09 9.98 10.50V 711.4 490.2 379.3 223.9 127.44 50.54 34.68 19.38 10.20 10.20V 755.9 507.8 391.0 229.1 129.73 51.00 34.87 19.48 10.25 9.90V 789.8 520.0 400.0 232.3 131.29 51.35 34.99 19.54 10.27 9.60V 816.0 530.4 408.0 234.6 132.60 51.66 35.10 19.54 10.27 M5 TERMINAL POSITION [M5 BOLT & NUT] USA: B&B BATTERY(USA) INC. 6415 RANDOLPH ST.COMMERCE, CA,90040 U.S.A. TEL:1-323-278-1900.1-800-278-8599 FAX:1-323-278-1268 E-Mail:[email protected] EUROPE: B&B BATTERY(EUROPE) B.V. 3 WIJNGAARDVELD, 9300 AALST,BELGIUM TEL:(00)32-53781567 FAX:(00)32-53781567 E-Mail:[email protected] RAOPING, GUANG DONG,CHINA,515700 TEL:86-768-7601001-2 FAX:86-768-7601469 E-Mail:[email protected] JAPAN: B&B BATTERY(JAPAN) CO., LTD. 1375-11 NARAHARA-MACHI,HACHIOJI, TOKYO 193-0803,JAPAN. TEL:81-426-25-6375 FAX:81-426-25-6375 E-Mail:[email protected] HONG KONG: NATIONAL TRADING LTD. TEL:852-2301-3800 FAX:852-2739-1182 E-Mail:[email protected] TAIWAN: B.B. BATTERY(TAIWAN) CO., LTD. TEL:886-6-502-5150 FAX:886-6-589-8087 E-Mail:[email protected] CHINA FACTORY: REV. Jul. 2005