Maintenance-Free Rechargeable Sealed Lead-Acid Battery HR22-12 (88W/Cell 15Min Rate) For High Rate Discharge The battery is constructed by plates, separators, safety valves and container. Since the electrolyte is held by a glassmat separator and plates, the battery can use in any direction and position without leakage. PERFORMANCE SPECIFICATIONS Nominal Voltage(V)................................................................................................................................12 volts(6cells in series) Nominal Capacity(AH) 10 Hour rate F.V.(1.75V/cell) (2.0A to 10.50volts) .......................................................................................................20.0A.H. 15 Min rate F.V.(1.30V/cell) (528W to 7.80volts) ..................................................................................................11.0A.H. Approximate Weight .........................................................................................................................................6500g(14.33lbs.) Terminal Standard..................................................................................................................................................................Type B1 Optional............................................................................................................................................................Type T2.I1 Internal Resistance (Fully Charged Battery)...................................................................................................................<9m Maximum Discharge Current For 5 sec.(A).....................................................................................................................300A Maximum Charge Current(A)........................................................................................................................................6.0A Ambient Temperature Charge.........................................................................................................................................0oC(32oF)~40oC(104oF) Discharge...................................................................................................................................-20oC(-4oF)~50oC(122oF) Storage.......................................................................................................................................-20oC(-4oF)~40oC(104oF) Vibration test: Frequency: 16.7HZ Amplitude: 4mm Vibrate the battery horizontally or vertically for 60 minutes. The battery have no abnormality. Case.....................................................................................................................................................................................ABS Dimension(mm/inch) Length 1.5mm...............................................................................................................................181/7.13 Width 1.5mm..........................................................................................................................76/2.99 Container Height 1.5mm.................................................................................................................................166/6.54 Total Height 1.5mm.............................................................................................................................166/6.54 Application........................................UPS, Fishing Lights, Booster, Emergency Lights, Lawn Mowers, Video Camcorders(VCR). HR22-12 Battery discharge characteristics (25 O C/77 O F) Battery Charging Characteristics (Typical example of the charge characteristic for the standby use) 3.4A 2.0A 5A 10.0 12A 9.0 15.0 120 0.18 14.0 0.15 13.0 80 60 40 Charge voltage(V) 11.0 0.21 100 Charge volume(%) Termind Voltage(V) 12.0 140 Charge current(CA) 13.0 0.12 0.09 0.06 20 0.03 0 0 Charge voltage C ha rg e vo lu m e 1 Discharge 100 %(0.1CA x 10h) 50 %(0.1CA x 5h) 2 Constant voltage charging Charge voltage:2.275V/cell Charge current:0.1CA O O 3 Temperature 20 C(68 F) 12.0 11.0 10.0 8.0 Charge current 100A 80A60A 40A 20A 0 0 10 5 7.0 1 2 3 5 10 20 30 60 2 5 3 10 20 15 25 Charge time (hr) 20 Hr Min Discharge time Effect of Temperature on Long Term Float Life Charging Procedure 10 8 Charging method Constant voltage & Constant current charging For (with current cycle service restrication) For standby power Source Max. charging current (CA) 2.25~2.30 -3 0.3 24 20 2.40~2.50 -4 0.3 16 10 Charging Voltage o at 20 C (V/cell) 100% discharge 6 5 Life expectancy(year) Application Charging time 0.1CA, 20 o C (h) Temperature compensation coefficient of charging voltage (mV/ o C/cell) 50% discharge *Temperature compensation of charging voltage is not needed,when using the batteries within5 o C to 35 o C range. Charging voltage : 2.275V/cell 4 3 2 1 0.5 20 68 6.35(0.25) 5.5( 0.22) Discharge time Final Voltage 5Min 10Min 15Min 7.85(0.31) [M5 BOLT & NUT] 20Min 30Min 40Min 50Min 60Min Battery output power(W) 3.4(0.13) 0.8(0.03) 11(0.43) 5(0.20) 2(0.08) 76 1.5(2.99 0.06) 181 1.5(7.13 0.06) C F o Terminal T2 Terminal B1 12(0.47) o 50 122 Constant power discharge characteristics at 25OC/77 OF mm(inch) mm(inch) 40 104 Battery temperature TERMINAL TYPE OUTER DIMENSIONS 30 86 10.80V 902 616.0 446.1 380.6 289.3 220.0 183.7 161.7 10.20V 1078 687.5 485.1 403.2 301.4 228.3 189.8 165.6 9.60V 1155 723.3 507.1 418.0 308.0 233.8 193.6 168.3 9.00V 1188 737.0 518.1 424.6 311.9 236.5 195.8 170.0 8.40V 1210 746.9 524.2 428.5 314.1 238.2 197.5 171.1 7.80V 1221 753.5 528.0 431.2 315.7 239.3 198.6 171.6 2.0(0.08) 166 1.5(6.54 0.06) Terminal I1 M5 TERMINAL POSITION [M5 BOLT & NUT] UL R MH19884 B.B. BATTERY CO., LTD. Web Site: http://www.bb-battery.com USA : B&B BATTERY (USA) INC. 6415 RANDOLPH ST. COMMERCE, CA, 90040 U.S.A. TEL: 1-323-278-1900 . 1-800-278-8599 FAX: 1-323-278-1268 CHINA FACTORY: CHENG DONG TRIAL AREA, HUANG GANG, RAOPING GUANG DONG, CHINA, 515700 TEL: 86-768-7601001-2 FAX: 86-768-7601469 UK: JAPAN: B & B BATTERY (UK) CO., LTD. TEL: 44-161-339-9458 FAX: 44-161-343-7030 B & B BATTERY(JAPAN) CO., LTD. TEL: 81-426-256-537 FAX: 81-426-256-537 HONG KONG: TAIWAN: NATIONAL TRADING LTD. B & B BATTERY CO., LTD. TEL: 852-2301-3800 FAX: 852-2739-1182 TEL: 886-6-5898081~3 FAX: 886-6-5898087 QUALITY ASSURED FIRM NATIONAL ACCREDITATION OF CERTIFICATION BODIES I S O 1 4 0 0 1 UKAS ENVIRONMENTAL MANAGEMENT Reg. No. 059-C