the datasheet ~950.84 KB

S70-1**, -2**, -3**, -4**Series
Screw mount vertical switch
Screw mount for installation from outside of tank
One, two, three, or four switch levels
Switch configurations of SPST or SPDT reed switch
contacts for high reliability
Enclosure Stainless Steel IP68 or Aluminium IP65
Safe area use only
All are custom built to suit particular applications,
based on information provided
The S70 series are vertical float switches
that are top mounted, via a screw thread
connection, from the outside of the tank.
Access to the inside of the tank is not
required for fitting the float switch.
These can be made with either 1, 2, 3 or 4
point level switches of either SPST or SPDT
action. The electrical loom is fully
insulated and encapsulated within the
stem of the device.
Designed to withstand the most arduous
applications, they are suitable for use in
Water, Diesel, Oil and hydraulic tanks and
reservoirs, as well as Chemical and Petrochemical storage and process control.
The float or floats follow the level of the
liquid and operate the SPST or SPDT switch
elements within the stem.
Technical Specification
Float Material
Stem Material
Temp. Range °C
°F
Min. Fluid SG
Conduit entry
Standard Screw
Minimum high level
Maximum low level
Terminations
Stainless Steel, D300 (PVC), Buna, Polypropylene, and others
Stainless Steel 316L, Brass
-20 / +135 dependant on float material
-4 / +275
dependant on float type
M20x1.5
G1”& G1 1/4”to G2 ½”other screw sizes available on request,
50mm from inboard end of screw thread
3500mm from inboard end of screw thread
Klippon screw type MK12
Electrical Specification
Switching Power Max
VA
Switching Voltage AC Max
V
Switching Voltage DC Max
V
Switching Current Max
A
All ratings are for resistive load only.
SPST
25
240
120
0.6
SPST
100
300
300
5
SPDT
25
250
250
1
SPDT
60
300
300
3
Applicable Standards
Low voltage directive
PED directive, where applicable
All are custom built to suit particular applications, based on information
provided. Please contact Cynergy3 with your requirements.
Information that is normally required:
The application and fluid in which the float switch will be used
That it is a safe area application
The Specific Gravity, SG, of the fluid
The maximum temperature of the fluid
Will the float switch will be fitted in a tank that is pressurised
The required thread size (If unknown we can specify)
The distance from the mounting face of the float switch to the switching
point or points. The switching action required at the switch points 'make on rise' or ‘make on fall'
Cynergy3 Components Ltd.
7 Cobham Road
Ferndown Industrial Estate
Wimborne, Dorset BH21 7PE
Telephone +44 (0) 1202 897969
Email:[email protected]
ISO9001 C E R T I F I E D
www.cynergy3.com