LM Series LM Seri

LM Series
This is suitable for use in water, industrial wastewater and sewage, that can have wide
variations of temperature. This small design of switch is for use in more confined spaces, where
there is not enough room for the larger FFSMC type.
The rounded body design and floating attitude prevents accumulation of solids on the body.
The switch has additional internal ballast, to bring the centre of gravity and rotation close to the
cable entry point.
The switching element is a self cleaning type, that makes the complete switch insensitive to
humidity and condensation, allowing this type to operate in widely fluctuating temperatures. The
switch contacts are rated at 10 Amp resistive.
Supplied, as standard, with 5 metres cable and adjustable counterweight.
Technical Specifications
LM10A
LM10B
LM10C
Contact Form
N/O
N/C
C/O
Material
High Density Polyethylene
Temp Range
°C
0 / +55
°F
+ 32 / +131
Cable (standard length 5m)
With protective earth
no earth
Standard cable covering
PVC
U cable option for Fuel oils
Polyurethane
Max. working pressure
10 bar
Electrical Specifications
Power Rating
Max
AC : 750 VA DC : 180W
Switching Voltage
Max
AC : 250 V DC : 110 V
Switching Current Max. Resistive
10 A
Switching Current Max. Inductive
AC : 4A DC : 1 A
It is necessary to use an auxiliary relay, when switching pump motors or any loads that are not
purely resistive.
• For smaller tanks and
restricted space
•
Use in sewer and
industrial waste
water
•
Shape avoids
“ragging”, in sewer
systems
•
Unaffected by
suspended solids
•
Operates in Turbulent
Fluids
MECHANICAL
47
15°
15°
Minimum Cable Pivot
length 120mm
ISO 9001C E R T I F IED
Off - On
Differential
On - Off
129
75
Cynergy3 Components Ltd
7 Cobham Road
Ferndown Industrial Estate
Wimborne
Dorset BH21 7PE
Tel: +44 (0) 1202 897969
[email protected]
www.cynergy3.com
© 2011 Cynergy3 Components, All Rights Reserved. Specifications are subject to change without prior notice. Cynergy3 Components and the Cynergy3 Components logo are trademarks of Cynergy3 Components Limited.
LM Series
Part Numbering System
LM
10 A U 10
Cable length in mtrs:
Series
Max. current
Blank = 5M standard
Cable covering:
Contact Form
Blank = PVC
U = Polyurethane
N = Neoprene
S = Silicone
A = n/o
B = n/c
C = c/o
Installation
cable entrance
cable
differential
external
tie
counterweight
pipe
wiring diagram
for emptying pump
wiring diagram
for filling pump
brown
brown
brown
blue
brown
black
blue
pump - off
level drop
pump - on
ISO 9001C E R T I F IED
black
pump - on
level drop
pump - off
www.cynergy3.com