LM Series This is suitable for use in water, industrial wastewater and sewage, that can have wide variations of temperature. This small design of switch is for use in more confined spaces, where there is not enough room for the larger FFSMC type. The rounded body design and floating attitude prevents accumulation of solids on the body. The switch has additional internal ballast, to bring the centre of gravity and rotation close to the cable entry point. The switching element is a self cleaning type, that makes the complete switch insensitive to humidity and condensation, allowing this type to operate in widely fluctuating temperatures. The switch contacts are rated at 10 Amp resistive. Supplied, as standard, with 5 metres cable and adjustable counterweight. Technical Specifications LM10A LM10B LM10C Contact Form N/O N/C C/O Material High Density Polyethylene Temp Range °C 0 / +55 °F + 32 / +131 Cable (standard length 5m) With protective earth no earth Standard cable covering PVC U cable option for Fuel oils Polyurethane Max. working pressure 10 bar Electrical Specifications Power Rating Max AC : 750 VA DC : 180W Switching Voltage Max AC : 250 V DC : 110 V Switching Current Max. Resistive 10 A Switching Current Max. Inductive AC : 4A DC : 1 A It is necessary to use an auxiliary relay, when switching pump motors or any loads that are not purely resistive. • For smaller tanks and restricted space • Use in sewer and industrial waste water • Shape avoids “ragging”, in sewer systems • Unaffected by suspended solids • Operates in Turbulent Fluids MECHANICAL 47 15° 15° Minimum Cable Pivot length 120mm ISO 9001C E R T I F IED Off - On Differential On - Off 129 75 Cynergy3 Components Ltd 7 Cobham Road Ferndown Industrial Estate Wimborne Dorset BH21 7PE Tel: +44 (0) 1202 897969 [email protected] www.cynergy3.com © 2011 Cynergy3 Components, All Rights Reserved. Specifications are subject to change without prior notice. Cynergy3 Components and the Cynergy3 Components logo are trademarks of Cynergy3 Components Limited. LM Series Part Numbering System LM 10 A U 10 Cable length in mtrs: Series Max. current Blank = 5M standard Cable covering: Contact Form Blank = PVC U = Polyurethane N = Neoprene S = Silicone A = n/o B = n/c C = c/o Installation cable entrance cable differential external tie counterweight pipe wiring diagram for emptying pump wiring diagram for filling pump brown brown brown blue brown black blue pump - off level drop pump - on ISO 9001C E R T I F IED black pump - on level drop pump - off www.cynergy3.com © 2011 Cynergy3 Components, All Rights Reserved. Specifications are subject to change without prior notice. Cynergy3 Components and the Cynergy3 Components logo are trademarks of Cynergy3 Components Limited.