Description Purpose and application The VISION motion detector detects the movements of people. The sensor is attached to ceilings and is ideal for mounting at great heights and for wide detection areas. The unit is mounted directly in a dry lining box or using the „mounting adapter“, optionally available from OSRAM, to ensure that the installation conforms to the CE guidelines. VISION The VISION motion detector can be connected to any control component with a floating input that is designed for permanent contact (switch). Function The motion detector detects motion within a detection area of 360° and switches on the connected luminaires when motion is registered. When motion is no longer registered, the luminaires switch off after an adjustable delay period. Design The sensor is made up of the following components: A B • Housing (A) • Connection cable (B): –– L: phase (black) –– N: neutral conductor (blue) Motion detector Operating instructions –– Floating switch contact (2x white) • Motion sensor (C) C • Button for setting the delay (D) • LED (E) E D Operation Setting the delay Note: When the motion detector is connected to the mains supply for the first time, it requires a warm-up phase of 1-3 minutes during which the internal switch contact is calibrated and the sensor functions are activated. The delay cannot be started and the programming mode cannot be activated until this warm-up phase is completed. Unlock and remove the plastic cover by turning it anticlockwise. Press button (D) 2x. The programming mode is activated. The currently set delay is indicated by flashing of the LED (E); see the table. Press the button one or more times, depending on the required delay; see the table. The newly set delay is confirmed by flashing of the LED; see the table. The confirmation is repeated three times. Replace the plastic cover and lock it by turning it clockwise. IX 2009 VISION_ba0911en_we1.01.indd Press/flash Delay 1x 30 s 2x 2.5 min 3x 5 min 4x 7.5 min 5x 10 min 6x 12.5 min 7x 15 min (default setting) 8x 17.5 min 9x 20 min OSRAM GmbH Kunden Service Center Customer-Service-Center (CSC) Steinerne Furt 62 86167 Augsburg Germany Tel : +49 (0) 1803 677 - 200 (kostenpflichtig / charges apply) Fax.: +49 (0) 1803 677 - 202 www.osram.com E www.osram.de 40083219570470 4008321957047 D Page 1 of 2 Troubleshooting Operation (cont.) If you cannot remedy the fault, please contact the customer service department of the manufacturer. The device is not functional The sensor is not correctly connected to the mains supply. à Follow the fitting instructions. The device is functional, but the switching functions are not being carried out The warm-up phase after startup was not completed. à Follow the instructions under „Setting the delay“. The floating switch contact is not connected correctly à Follow the fitting instructions. The device is carrying out an undesired functional mode The delay is not set correctly. à Follow the instructions under „Setting the delay“. Appendix Technical data Operating voltage 120 V … 277 V AC / 50-60 Hz Fuse External 16 A Switch output Floating switch contact Switch output load capacity Max. 5 A – 230 V Inductive load: 250 VA Ohmic lamp: 1200 W Max. number of ECGs: QTP5: 10 pcs. 1x14-35 8 pcs. 1x54 / 2x14-35 6 pcs. 2x80 / 2x54 QTP8: 10 pcs. 1x58 6 pcs. 2x58 QT-FIT8:10 pcs. 1x58 / 1x36 6 pcs. 2x58 / 2x36 QTi: 15 pcs. 1x28/54 10 pcs. 2x28/54 6 pcs. 2x35/49/80 Operating temperature -10 °C … +70 °C Protection type IP 20 Dimensions (Ø x H) 115.6 x 39.9 mm Dimensioned drawing Ø 115,6 mm 39,9 mm The EMC requirements to EN 55015 are fulfilled. Conformity with the relevant EU directives is confirmed by the CE symbol. Page 2 of 2