Operating instructions OSRAM VISION sensor

Description
Purpose and application
The VISION motion detector detects the movements of people.
The sensor is attached to ceilings and is ideal for mounting at
great heights and for wide detection areas. The unit is mounted
directly in a dry lining box or using the „mounting adapter“,
optionally available from OSRAM, to ensure that the installation
conforms to the CE guidelines.
VISION
The VISION motion detector can be connected to any control
component with a floating input that is designed for permanent
contact (switch).
Function
The motion detector detects motion within a detection area of
360° and switches on the connected luminaires when motion is
registered. When motion is no longer registered, the luminaires
switch off after an adjustable delay period.
Design
The sensor is made up of the following components:
A
B
• Housing (A)
• Connection cable (B):
–– L: phase (black)
–– N: neutral conductor (blue)
Motion detector
Operating instructions
–– Floating switch contact (2x white)
• Motion sensor (C)
C
• Button for setting the delay (D)
• LED (E)
E
D
Operation
Setting the delay
Note: When the motion detector is connected to the mains supply for the first time, it requires a warm-up phase of 1-3 minutes
during which the internal switch contact is calibrated and the
sensor functions are activated. The delay cannot be started and
the programming mode cannot be activated until this warm-up
phase is completed.
Unlock and remove the plastic cover by turning it anticlockwise.
‚Press button (D) 2x.
The programming mode is activated. The currently set delay
is indicated by flashing of the LED (E); see the table.
ƒPress the button one or more times, depending on the
required delay; see the table.
„The newly set delay is confirmed by flashing of the LED; see
the table. The confirmation is repeated three times.
…Replace the plastic cover and lock it by turning it clockwise.
IX 2009
VISION_ba0911en_we1.01.indd
Press/flash
Delay
1x
30 s
2x
2.5 min
3x
5 min
4x
7.5 min
5x
10 min
6x
12.5 min
7x
15 min (default setting)
8x
17.5 min
9x
20 min
OSRAM GmbH
Kunden Service Center
Customer-Service-Center (CSC)
Steinerne Furt 62
86167 Augsburg
Germany
Tel : +49 (0) 1803 677 - 200
(kostenpflichtig / charges apply)
Fax.: +49 (0) 1803 677 - 202
www.osram.com
E
www.osram.de
40083219570470
4008321957047
D
Page 1 of 2
Troubleshooting
Operation (cont.)
If you cannot remedy the fault, please contact the customer
service department of the manufacturer.
The device is not functional
The sensor is not correctly connected to the mains supply.
à Follow the fitting instructions.
The device is functional, but the switching functions are
not being carried out
The warm-up phase after startup was not completed.
à Follow the instructions under „Setting the delay“.
The floating switch contact is not connected correctly
à Follow the fitting instructions.
The device is carrying out an undesired functional mode
The delay is not set correctly.
à Follow the instructions under „Setting the delay“.
Appendix
Technical data
Operating voltage
120 V … 277 V AC / 50-60 Hz
Fuse
External 16 A
Switch output
Floating switch contact
Switch output load
capacity
Max. 5 A – 230 V
Inductive load: 250 VA
Ohmic lamp: 1200 W
Max. number of ECGs:
QTP5:
10 pcs. 1x14-35
8 pcs. 1x54 / 2x14-35
6 pcs. 2x80 / 2x54
QTP8:
10 pcs. 1x58
6 pcs. 2x58
QT-FIT8:10 pcs. 1x58 / 1x36
6 pcs. 2x58 / 2x36
QTi:
15 pcs. 1x28/54
10 pcs. 2x28/54
6 pcs. 2x35/49/80
Operating temperature
-10 °C … +70 °C
Protection type
IP 20
Dimensions
(Ø x H)
115.6 x 39.9 mm
Dimensioned drawing
Ø 115,6 mm
39,9 mm
The EMC requirements to EN 55015 are fulfilled.
Conformity with the relevant EU directives is
confirmed by the CE symbol.
Page 2 of 2