HALODIUM II LUM – Technical Information Floodlight for a perfect backdrop Tender text • A whole range of projectors for outdoor applications like Monuments, Squares, Sports facilities, Parks, Private & Public Garden, Parking and Garages. Outdoor and Indoor Illumination, everywhere you need good association between illuminating efficacy with high quality discharge lamps HQI or NAV and waterproof protection. • An aluminium casting body, protection window in tempered glass, hammered reflector. • 230 V Input Supply Voltage. • Equipped with CCG and lamps for each application like HQI & NAV. • Exist in versions delivered without lamp (but not for HQI NSI lamp type). • IP 66. Table of contents: Tender text ................................................................................................... 1 A) Technical Information............................................................................. 2 1) Housing, Mounting and Accessories .......................................................................2 2) Electrical Installation .................................................................................................5 3) Optical features ..........................................................................................................6 4) Control ........................................................................................................................9 B) Logistic Data ......................................................................................... 10 LUM – Technical Information Subject to modification HALODIUM II Status as of 22.10.2010 Page 1 / 11 HALODIUM II A) Technical Information 1) Housing, Mounting and Accessories • Aluminium casting body, anti-corrosion treatment. The high quality level treatment can guarantee using in front of see. • Protection window in tempered glass. • Symmetric and asymmetric hammered reflector. Product name HALODIUM II 70W SYM & ASM HALODIUM II 150W SYM & ASM Body material HALODIUM II 250W & 400W SYM & ASM An aluminium casting body Color of the luminaire (RAL) Anthracite Cover material Tempered glass with aluminium closing clips Type of cover Glass Reflector material Hammered Aluminium Reflector Symmetry Number of lighting outlets Symmetric and Asymmetric 1 1 1 Length l [mm] 340 440 535 Width b [mm] 214 260 437 Height h [mm] 112 120 Net weight [g] 3420 5396 195 10960 (250W) 12260 (400W) LUM – Technical Information Subject to modification HALODIUM II Status as of 22.10.2010 Page 2 / 11 HALODIUM II HALODIUM II 70W SYM & ASM HALODIUM II 150W SYM & ASM HALODIUM II 250W & 400W SYM & ASM LUM – Technical Information Subject to modification HALODIUM II Status as of 22.10.2010 Page 3 / 11 HALODIUM II Product name HALODIUM II 70W SYM & ASM HALODIUM II 150W SYM & ASM I Protection class Type of protection (IP code) Protection against ignition and fire Glow Wire Test according to IEC 695-2-1 (> 650°C) Shock resistance (IK code) IP 66 F 850 °C IK06 IK08 Ambient temperature -20 °C up to + 35 °C Temperature range [°C] -20 °C up to + 35 °C Storage temperature [°C] -20 °C up to + 35 °C Approval marks CE - ENEC 10 VDE Surface Resistance Wind HALODIUM II 250W & 400W SYM & ASM ≤ 0,065M² ≤ 0,10M² ≤ 0,17M² PROTECTIVE GRID Galvanized steel LOUVER SHIELD Anthracite powder coated galvanized steel MOUNTING BRACKET PROTECTIVE SHIELD 70 W ASM LUM – Technical Information Subject to modification 70 W SYM 150 W ASM + SYM HALODIUM II 250/400 W ASM + SYM Status as of 22.10.2010 Page 4 / 11 HALODIUM II For special applications EYESHADE SUPPORT FOR DISTANCE made of light Anthracite painted steel only on order made of stainless steel AISI 304 FIXING BRACKET only on order WALL MOUNTING PLATE made of light Anthracite painted steel only on order POLE FIXING RING made of galvanized steel complete with screws Ø 48 Ø 60 Ø 78 only on order 2) Electrical Installation • Easy installation. • Use cable type H05 RNF or H07 RNF (not delivered) Product name Nominal wattage [W] HALODIUM II 70W SYM & ASM 70 HALODIUM II 150W SYM & ASM 150 Mains voltage [V] 230 V Mains frequency [Hz] 50 Hz LUM – Technical Information Subject to modification HALODIUM II HALODIUM II 250W & 400W SYM & ASM 250/400 Status as of 22.10.2010 Page 5 / 11 HALODIUM II 3) Optical features • High luminous efficacy and luminous flux by hammered aluminium reflector • Long life by optimization between lamp and reflector for efficacity and lifetime. • The best ratio between efficiency and illuminating. Product name Equipped with Lamp Lamp type Base HALODIUM II 70W HALODIUM II 150W HALODIUM II 250W & SYM & ASM SYM & ASM 400W SYM & ASM 2 versions : with and without lamp HQI-T/BT or HQI/NSI or NAV-T (no HQI/NSI HQI-TS or NAV-TS HQI-TS or NAV-TS for version without lamp) R7x R7x E40 HALODIUM II TS 70W NDL SYM HALODIUM II TS 70W NAV SYM HALODIUM II TS 70W NDL ASM HALODIUM II TS 70W NAV ASM LUM – Technical Information Subject to modification HALODIUM II Status as of 22.10.2010 Page 6 / 11 HALODIUM II HALODIUM II TS 150W NDL SYM HALODIUM II TS 150W NAV SYM HALODIUM II TS 150W NDL ASM HALODIUM II TS 150W NAV ASM HALODIUM II T 250W NSI SYM HALODIUM II T 250W D SYM LUM – Technical Information Subject to modification HALODIUM II Status as of 22.10.2010 Page 7 / 11 HALODIUM II HALODIUM II T 250W NAV SYM HALODIUM II T 250W NSI ASM HALODIUM II T 250W D ASM HALODIUM II T 250W NAV ASM HALODIUM II T 400W NSI SYM HALODIUM II BT 400W D SYM LUM – Technical Information Subject to modification HALODIUM II Status as of 22.10.2010 Page 8 / 11 HALODIUM II HALODIUM II T 400W NAV SYM HALODIUM II T 400W NSI ASM HALODIUM II BT 400W D ASM HALODIUM II T 400W NAV ASM 4) Control • Powered by 230 V Product name HALODIUM II 70W SYM & ASM HALODIUM II 150W SYM & ASM Ballast control gear CCG Input voltage 230 V LUM – Technical Information Subject to modification HALODIUM II HALODIUM II 250W & 400W SYM & ASM Status as of 22.10.2010 Page 9 / 11 HALODIUM II B) Logistic Data Product reference Product number (EAN 10) Color Wattage SU SYMMETRICAL REFLECTOR HALODIUM II TS 70W NDL SYM HALODIUM II TS 70W NAV SYM HALODIUM II TS 150W NDL SYM HALODIUM II TS 150W NAV SYM HALODIUM II T 250W NSI SYM HALODIUM II T 250W D SYM HALODIUM II T 250W NAV SYM HALODIUM II T 400W NSI SYM HALODIUM II BT 400W D SYM HALODIUM II T 400W NAV SYM 4008321 940063 4008321 940148 4008321 940087 4008321 940162 4008321 940223 4008321 940100 4008321 940186 4008321 940247 4008321 940124 4008321 940209 ANTHRACITE ANTHRACITE ANTHRACITE ANTHRACITE ANTHRACITE ANTHRACITE ANTHRACITE ANTHRACITE ANTHRACITE ANTHRACITE 70 W 70 W 150 W 150 W 250 W 250 W 250 W 400 W 400 W 400 W 1 1 1 1 1 1 1 1 1 1 Without lamp: (NOT FOR HQI NSI lamp!) HALODIUM II AZ 70W SYM HALODIUM II AZ 150W SYM HALODIUM II AZ 250W SYM HALODIUM II AZ 400W SYM 4008321 582881 4008321 582904 4008321 583413 4008321 583437 ANTHRACITE ANTHRACITE ANTHRACITE ANTHRACITE 70 W 150 W 250 W 400 W 1 1 1 1 ASYMMETRICAL REFLECTOR HALODIUM II TS 70W NDL ASM HALODIUM II TS 70W NAV ASM HALODIUM II TS 150W NDL ASM HALODIUM II TS 150W NAV ASM HALODIUM II T 250W NSI ASM HALODIUM II T 250W D ASM HALODIUM II T 250W NAV ASM HALODIUM II T 400W NSI ASM HALODIUM II BT 400W D ASM HALODIUM II T 400W NAV ASM 4008321 940070 4008321 940155 4008321 940094 4008321 940179 4008321 940230 4008321 940117 4008321 940193 4008321 940254 4008321 940131 4008321 940216 ANTHRACITE ANTHRACITE ANTHRACITE ANTHRACITE ANTHRACITE ANTHRACITE ANTHRACITE ANTHRACITE ANTHRACITE ANTHRACITE 70 W 70 W 150 W 150 W 250 W 250 W 250 W 400 W 400 W 400 W 1 1 1 1 1 1 1 1 1 1 Without lamp : (NOT FOR HQI NSI lamp!) HALODIUM II AZ 70W ASM HALODIUM II AZ 150W ASM HALODIUM II AZ 250W ASM HALODIUM II AZ 400W ASM 4008321 582898 4008321 582911 4008321 583420 4008321 583444 ANTHRACITE ANTHRACITE ANTHRACITE ANTHRACITE 70 W 150 W 250 W 400 W 1 1 1 1 LUM – Technical Information Subject to modification HALODIUM II Status as of 22.10.2010 Page 10 / 11 HALODIUM II Accessories: Product reference Product number (EAN 10) Color SU PROTECTION GRID 70 W PROTECTION GRID 150 W PROTECTION GRID 250-400 W 4008321 624871 4008321 624888 4008321 624895 Galvanized steel 1x1 1x1 1x1 LOUVER SHIELD 70 W LOUVER SHIELD 150 W LOUVER SHIELD 250-400 W 4008321 624857 4008321 624864 4008321 624901 Anthracite powder coated galvanized steel 1x1 1x1 1x1 HALODIUM II BRACKET 70-150 W HALODIUM II BRACKET 250/400 W 4008321 380388 4008321 380395 Anthracite 1x1 1x1 HALODIUM II SYM 70 W GLASS HALODIUM II ASM 70 W GLASS HALODIUM II ASM / SYM 150 W GLASS HALODIUM II ASM / SYM 250-400W GLASS 4008321 388322 4008321 388339 4008321 388346 4008321 388360 LUM – Technical Information Subject to modification HALODIUM II 1x1 1x1 1x1 1x1 Status as of 22.10.2010 Page 11 / 11