SAW Components SAW Duplexer LTE Band II (PCS) Series/type: Ordering code: B8663 B39202-B8663-P810 Date: Version: November 18, 2014 2.1 EPCOS AG 2015. Reproduction, publication and dissemination of this publication, enclosures hereto and the information contained therein without EPCOS' prior express consent is prohibited. EPCOS AG is a TDK Group Company. SAW Components B8663 SAW Duplexer 1880.0 / 1960.0 MHz Data sheet Application ■ Low-loss SAW duplexer for mobile telephone LTE Band II (PCS) systems ■ Low insertion attenuation ■ Low amplitude ripple ■ Usable passband 60 MHz 0.3 0.3 ■ Package size 1.8 x 1.4 mm2, ■ ■ ■ 0.7 max. height 0.475 mm RoHS compatible Approx. weight 0.0035 g Package for Surface Mount Technology (SMT) Ni, gold-plated terminals Electrostatic Sensitive Device (ESD) Moisture Sensitive Level 3 (MSL) 0.35 2 3 4 8 7 0.5 max. ■ ■ ■ 1 6 5 0.25 0.25 Features bottom view 0.475 max side view 1.8 1.4 7 6 5 8 4 1 2 top view 3 Pin configuration ■ ■ ■ ■ 3 1 6 2, 4, 5, 7, 8 TX input RX output Antenna To be grounded 31 13 7,8,9 2,7,8 2,4,5 4,5 66 Please read cautions and warnings and important notes at the end of this document. 2 November 26, 2014 SAW Components B8663 SAW Duplexer 1880.0 / 1960.0 MHz Data sheet Characteristics Temperature range for specification: ANT terminating impedance: RX terminating impedance: TX terminating impedance: T = –20 ˚C to +90 ˚C ZANT = 50 Ω II 3.5 nH ZRX = 50 Ω + 1.6 nH ZTX = 50 Ω Characteristics TX - ANT Center frequency fC Maximum insertion attenuation 1852.5 ...1907.5 MHz αLTE 1) Error Vector Magnitude @fCarrier 1852.4 ...1907.6 MHz EVM 2) Input VSWR (TX port) 1850.24 ...1909.76 MHz Output VSWR (RX port) 1850.24 ...1909.76 MHz Attenuation 1) — max. — MHz 1.6 2.5 dB — 0.6 3.0 % — 1.3 2.0 — 1.3 2.0 30 40 38 35 41 41 30 44 20 30 10 27 21 23 43 43 41 37 45 48 40 52 50 33 14 30 25 27 — — — — — — — — — — — — — — α 10.0 728.0 869.0 1226.0 1559.0 1597.5 1605.8 1932.5 2010.0 2110.0 2400.0 3700.0 4900.0 5550.0 2) — B8663 typ. @ 25˚C 1880.0 min. ... ... ... ... ... ... ... ... ... ... ... ... ... ... 787.0 MHz 764.0 MHz 894.0 MHz 1250.0 MHz 1585.5 MHz 1605.9 MHz 1680.0 MHz 1987.5MHz αLTE 2025.0 MHz 2155.0 MHz 2500.0 MHz 3820.0 MHz 5950.0 MHz 5730.0 MHz Averaged value of linear s-parameter over 5 MHz Error Vector Magnitude (EVM) based on definition given in 3GPP TS 25.141. Please read cautions and warnings and important notes at the end of this document. 3 November 26, 2014 dB dB dB dB dB dB dB dB dB dB dB dB dB dB SAW Components B8663 SAW Duplexer 1880.0 / 1960.0 MHz Data sheet Characteristics Temperature range for specification: ANT terminating impedance: RX terminating impedance: TX terminating impedance: T = –20 ˚C to +90 ˚C ZANT = 50 Ω II 3.5 nH ZRX = 50 Ω + 1.6 nH ZTX = 50 Ω Characteristics ANT - RX Center frequency fC Maximum insertion attenuation 1932.5 ... 1987.5 MHz αLTE 1) Input VSWR (ANT port) 1930.24 ...1989.76 MHz Output VSWR (RX port) 1930.24 ...1989.76 MHz Attenuation α 0.2 ... 1850.0 MHz 80.0 MHz 1852.5 ... 1907.5 MHz αLTE 2050.0 ... 2075.0 MHz 2075.0 ... 2350.0 MHz 2350.0 ... 2550.0 MHz 2550.0 ... 6000.0 MHz 5610.0 ... 5845.0 MHz 1) — max. — MHz 2.1 3.0 dB — 1.3 2.0 — 1.2 2.0 43 50 45 25 35 20 40 48 46 >60 52 37 44 28 51 52 — — — — — — — — min. B8663 typ. @ 25˚C max. 40 54 55 20 20 64 58 62 56 53 — — — — — dB dB dB dB dB dB dB dB Averaged value of linear s-parameter over 5 MHz Characteristics TX - RX Isolation α 1574.0 1852.5 1932.5 3700.0 5550.0 1) — B8663 typ. @ 25˚C 1960.0 min. ... 1577.0 MHz ... 1907.5 MHz αLTE 1) ... 1987.5 MHz αLTE ... 3820.0 MHz ... 5850.0 MHz Averaged value of linear s-parameter over 5 MHz Please read cautions and warnings and important notes at the end of this document. 4 November 26, 2014 dB dB dB dB dB SAW Components B8663 SAW Duplexer 1880.0 / 1960.0 MHz Data sheet Maximum ratings Operable temperature range Storage temperature range DC voltage ESD voltage ESD voltage ESD voltage Input power at 1850.24 ... 1909.76 MHz elsewhere 1) acc. to JESD22-A114F (HBM) 2) acc. to JESD22-C101C (CDM) 3) acc. to JESD22-A115B (MM) T Tstg VDC VESD VESD VESD PIN Please read cautions and warnings and important notes at the end of this document. –30/+90 –40/+90 0 250 600 150 29 10 ˚C ˚C V V V V dBm dBm 5 human body model 1) charge device model 2) machine model 3) source and load impedance 50 Ω continuous wave T = 50˚C, >5.000 h } November 26, 2014 SAW Components B8663 SAW Duplexer 1880.0 / 1960.0 MHz Data sheet Frequency response TX - ANT (passband, averaged value of linear s-parameter over 5 MHz) Frequency response TX - ANT (averaged value of linear s-parameter over 5 MHz) Please read cautions and warnings and important notes at the end of this document. 6 November 26, 2014 SAW Components B8663 SAW Duplexer 1880.0 / 1960.0 MHz Data sheet Frequency response TX - ANT (wideband) Frequency response ANT - RX (passband, averaged value of linear s-parameter over 5 MHz) Please read cautions and warnings and important notes at the end of this document. 7 November 26, 2014 SAW Components B8663 SAW Duplexer 1880.0 / 1960.0 MHz Data sheet Frequency response ANT - RX (averaged value of linear s-parameter over 5 MHz) Frequency response ANT - RX (wideband) Please read cautions and warnings and important notes at the end of this document. 8 November 26, 2014 SAW Components B8663 SAW Duplexer 1880.0 / 1960.0 MHz Data sheet Frequency response TX - RX isolation (averaged value of linear s-parameter over 5 MHz) Please read cautions and warnings and important notes at the end of this document. 9 November 26, 2014 SAW Components B8663 SAW Duplexer 1880.0 / 1960.0 MHz Data sheet VSWR S11 TX-port VSWR S33 RX-port VSWR S22 ANT-port Please read cautions and warnings and important notes at the end of this document. 10 November 26, 2014 SAW Components B8663 SAW Duplexer 1880.0 / 1960.0 MHz Data sheet References Type B8663 Ordering code B39202-B8663-P810 Marking and package C61157-A8-A87 Packaging F61074-V8259-Z000 Date codes L_1126 B8663_NB_UN.s3p (unmatched, narrow band) S-parameters B8663_WB_UN.s3p (unmatched, wide band) see file header for port/pin assignment table Soldering profile S_6001 RoHS compatible defined as compatible with the following documents: "DIRECTIVE 2002/95/EC OF THE EUROPEAN PARLIAMENT AND OF THE COUNCIL of 27 January 2003 on the restriction of the use of certain hazardous substances in electrical and electronic equipment. 2005/618/EC from April 18th, 2005, amending Directive 2002/95/EC of the European Parliament and of the Council for the purposes of establishing the maximum concentration values for certain hazardous substances in electrical and electronic equipment." For further information please contact your local EPCOS sales office or visit our webpage at www.epcos.com . Published by EPCOS AG Systems, Acoustics, Waves Business Group P.O. Box 80 17 09, 81617 Munich, GERMANY EPCOS AG 2014. This brochure replaces the previous edition. For questions on technology, prices and delivery please contact the Sales Offices of EPCOS AG or the international Representatives. Due to technical requirements components may contain dangerous substances. For information on the type in question please also contact one of our Sales Offices. Please read cautions and warnings and important notes at the end of this document. 11 November 26, 2014 SAW Components B8663 SAW Duplexer 1880.0 / 1960.0 MHz Data sheet Matching coils See Inductor pdf-catalog http://www.tdk.co.jp/tefe02/coil.htm#aname1 and Data Library for circuit simulation http://www.tdk.co.jp/etvcl/index.htm for a large variety of matching coils. Please read cautions and warnings and important notes at the end of this document. 12 November 26, 2014 Important notes The following applies to all products named in this publication: 1. 2. 3. 4. 5. 6. 7. Some parts of this publication contain statements about the suitability of our products for certain areas of application. These statements are based on our knowledge of typical requirements that are often placed on our products in the areas of application concerned. We nevertheless expressly point out that such statements cannot be regarded as binding statements about the suitability of our products for a particular customer application. As a rule, EPCOS is either unfamiliar with individual customer applications or less familiar with them than the customers themselves. For these reasons, it is always ultimately incumbent on the customer to check and decide whether an EPCOS product with the properties described in the product specification is suitable for use in a particular customer application. We also point out that in individual cases, a malfunction of electronic components or failure before the end of their usual service life cannot be completely ruled out in the current state of the art, even if they are operated as specified. In customer applications requiring a very high level of operational safety and especially in customer applications in which the malfunction or failure of an electronic component could endanger human life or health (e.g. in accident prevention or life-saving systems), it must therefore be ensured by means of suitable design of the customer application or other action taken by the customer (e.g. installation of protective circuitry or redundancy) that no injury or damage is sustained by third parties in the event of malfunction or failure of an electronic component. The warnings, cautions and product-specific notes must be observed. In order to satisfy certain technical requirements, some of the products described in this publication may contain substances subject to restrictions in certain jurisdictions (e.g. because they are classed as hazardous). Useful information on this will be found in our Material Data Sheets on the Internet (www.epcos.com/material). Should you have any more detailed questions, please contact our sales offices. We constantly strive to improve our products. Consequently, the products described in this publication may change from time to time. The same is true of the corresponding product specifications. Please check therefore to what extent product descriptions and specifications contained in this publication are still applicable before or when you place an order. We also reserve the right to discontinue production and delivery of products. Consequently, we cannot guarantee that all products named in this publication will always be available. The aforementioned does not apply in the case of individual agreements deviating from the foregoing for customer-specific products. Unless otherwise agreed in individual contracts, all orders are subject to the current version of the “General Terms of Delivery for Products and Services in the Electrical Industry” published by the German Electrical and Electronics Industry Association (ZVEI). The trade names EPCOS, BAOKE, Alu-X, CeraDiode, CeraLink, CeraPlas, CSMP, CSSP, CTVS, DeltaCap, DigiSiMic, DSSP, FilterCap, FormFit, MiniBlue, MiniCell, MKD, MKK, MLSC, MotorCap, PCC, PhaseCap, PhaseCube, PhaseMod, PhiCap, SIFERRIT, SIFI, SIKOREL, SilverCap, SIMDAD, SiMic, SIMID, SineFormer, SIOV, SIP5D, SIP5K, TFAP, ThermoFuse, WindCap are trademarks registered or pending in Europe and in other countries. Further information will be found on the Internet at www.epcos.com/trademarks. 13 November 26, 2014