C20F Power Entry Modules with Line Filter www.schurter.com/PG06 IEC Appliance Inlet C20 with Filter, Front or Rear Side Mounting Screw-on mounting from front side Standard- or Medical-Filter Snap-in mounting from front side Screw-on mounting from rear side with wires (stranded) C20 70° C Description Characteristics Approvals Other versions on request -Panel Mount: Screw-on version from front or rear side, snap-in version from front side -2 Functions: Appliance Inlet Protection class I, Line filter in standard and medical version -Solder, quick connect or wires (stranded) -VDE Certificate Number: 104884 -UL File Number: E72928 -Compact design with optimal shielding Suitable for assembly in metal plated plastic housings -Version with class X1 and X2 (standard version) capacitors -Universal line filter for standard applications Designed for standard and medical applications -Suitable for use in equipment according to IEC/UL 60950 Suitable for use in medical equipment according to IEC/UL 60601-1 -16A according to UL -Capacity CX 330 nF References Alternative: version without line filter 4793; 4798 Weblinks pdf-datasheet, html-datasheet, General Product Information, Approvals, CE declaration of conformity, RoHS, CHINA-RoHS, REACH, Mating Connectors, e-Shop, SCHURTER-Stock-Check, Distributor-StockCheck, CAD-Drawings, Accessories, Wire Harnessing, Detailed request for product Newly available variants corresponding to V-Lock mating cordset. The connector is equipped with a notch intended for use with the latching cordset. The cord latching system prevents against accidental removal of the cordset. Technical Data Ratings IEC Ratings UL/CSA Leakage Current Dielectric Strength Impulse Withstand Voltage Allowable Operation Temp. Climatic Category Degree of Protection Protection Class Terminal Panel Thickness s Material: Housing 16 A @ Ta 40 °C / 250 VAC; 50 Hz 20 A @ Ta 40 °C / 250 VAC; 60 Hz standard < 0.5 mA (250 V / 60 Hz) medical < 5 µA (250 V / 60 Hz) > 1.7 kVDC between L-N > 2.7 kVDC between L/N-PE Test voltage (2 sec) > 2.5 kV between L-N (CX2) > 4 kV between L-N (CX1) > 5 kV between L/N-PE (Cy2) voltage (1.2/50 μs) -25 °C to 85 °C 25/085/21 acc. to IEC 60068-1 from front side IP 40 acc. to IEC 60529 Suitable for appliances with protection class I acc. to IEC 61140 Solder, quick connect or wires (stranded) Screw: max 8 mm Mounting screw torque max 0.5 Nm Snap-in: 1 mm to 3 mm Thermoplastic, black, UL 94V-0 Appliance-Inlet/-Outlet Line Filter MTBF C20 acc. to IEC 60320, UL 498, CSA C22.2 no. 42 (for cold conditions) pin-temperature 70 °C, 16 A, Protection Class I Standard and Medical Version, IEC 60939, UL 1283, CSA C22.2 no. 8 Technical Details > 3'000'000 h acc. to MIL-HB-217 F Connectors 1 C20F Power Entry Modules with Line Filter www.schurter.com/PG06 Dimension Screw-on mounting from front side 10.3 R6 6.3 x 0.8 * 3.5/M3 64.65 30 3.85 42 ±0.15 34.8 +0.20 0 ø 6x80° 33.90 x 25.90 53 42 3.4 9.4 R3 26.8 +0.20 0 78.8 * Solder terminal: identical outer dimensions Screw-on mounting from rear side with metal flange 3 10.3 R6 3.5 max. R 0.5 M3 28 64.65 30 78.8 42 ±0.15 33.90 x 25.90 53 36 42 R 0.5 36.4 +0.20 0 9.4 3.85 28.3 +0.20 0 Snap-in mounting from front side 10.3 38 33.90 x 25.85 34.8 +0.20 0 9.4 R2 64.65 30 3.85 78.8 Technical Data of Filter-Components Rated Current [A] 16 Filter-Type Standard Version Inductances L [mH] Capacitance CX [nF] Capacitance CY [nF] R [MΩ] 2 x 0.3 100 2.2 1 16 Medical Version (M5) 2 x 0.3 100 - 1 16 Medical Version (M80) 2 x 0.3 100 0.47 1 2 Connectors R3 26.3 +0.20 0 C20F Power Entry Modules with Line Filter www.schurter.com/PG06 Diagrams Standard or medical version (M80) Medical version (M5) L L’ L L’ L1 1) PE Cx L1 Cy R L2 N Cy PE’ 2) 1) PE N’ 1) Line 2) Load Cx PE’ 2) R L2 N N’ 1) Line 2) Load Attenuation Loss - - - - differential mode _____ common mode Standard version 20 A Medical version (M5) 20 A All Variants Rated Current IEC [A] Rated Current Filter-Type UL [A] Panel mounting Mounting side Terminal Capacitor Order Number 16 20 Standard Version Snap-in Front Side Quick connect terminals 6.3 x 0.8 X2 100nF C20F.0111 16 20 Standard Version Snap-in Front Side Quick connect terminals 6.3 x 0.8 X1 100nF C20F.0113 16 20 Standard Version Snap-in Front Side Solder terminals X2 100nF C20F.0011 16 20 Standard Version Snap-in Front Side Solder terminals X1 100nF C20F.0013 16 20 Standard Version Screw Front Side Quick connect terminals 6.3 x 0.8 X2 100nF C20F.0101 16 20 Standard Version Screw Front Side Quick connect terminals 6.3 x 0.8 X2 100nF C20F.0101.21 16 20 Standard Version Screw Front Side Quick connect terminals 6.3 x 0.8 X1 100nF C20F.0103 16 20 Standard Version Screw Front Side Solder terminals X2 100nF C20F.0001 16 20 Standard Version Screw Front Side Solder terminals X2 100nF C20F.0001.21 16 20 Standard Version Screw Front Side Solder terminals X1 100nF C20F.0003 16 20 Standard Version Screw Rear Side Flexible wire AWG14 X2 100nF C20F.0221 16 20 Standard Version Screw Rear Side Flexible wire AWG14 X1 100nF C20F.0223 16 20 Standard Version Screw Rear Side Quick connect terminals 6.3 x 0.8 X2 100nF C20F.0121 16 20 Standard Version Screw Rear Side Quick connect terminals 6.3 x 0.8 X1 100nF C20F.0123 16 20 Standard Version Screw Rear Side Solder terminals X2 100nF C20F.0021 16 20 Standard Version Screw Rear Side Solder terminals X1 100nF C20F.0023 16 20 Medical Version (M5) Snap-in Front Side Quick connect terminals 6.3 x 0.8 X2 100nF C20F.0112 16 20 Medical Version (M5) Snap-in Front Side Quick connect terminals 6.3 x 0.8 X1 100nF C20F.0114 Connectors █ █ █ 3 C20F Rated Current IEC [A] Power Entry Modules with Line Filter www.schurter.com/PG06 Rated Current Filter-Type UL [A] Panel mounting Mounting side Terminal Capacitor Order Number 16 20 Medical Version (M5) Snap-in Front Side Solder terminals X2 100nF C20F.0012 16 20 Medical Version (M5) Snap-in Front Side Solder terminals X1 100nF C20F.0014 16 20 Medical Version (M5) Screw Front Side Quick connect terminals 6.3 x 0.8 X2 100nF C20F.0102 16 20 Medical Version (M5) Screw Front Side Quick connect terminals 6.3 x 0.8 X1 100nF C20F.0104 16 20 Medical Version (M5) Screw Front Side Solder terminals X2 100nF C20F.0002 16 20 Medical Version (M5) Screw Front Side Solder terminals X1 100nF C20F.0004 16 20 Medical Version (M5) Screw Rear Side Flexible wire AWG14 X2 100nF C20F.0222 16 20 Medical Version (M5) Screw Rear Side Flexible wire AWG14 X1 100nF C20F.0224 16 20 Medical Version (M5) Screw Rear Side Quick connect terminals 6.3 x 0.8 X2 100nF C20F.0122 16 20 Medical Version (M5) Screw Rear Side Quick connect terminals 6.3 x 0.8 X1 100nF C20F.0124 16 20 Medical Version (M5) Screw Rear Side Solder terminals X2 100nF C20F.0022 16 20 Medical Version (M5) Screw Rear Side Solder terminals X1 100nF C20F.0024 █ Most Popular. Availability for all products can be searched real-time:http://www.schurter.com/en/Stock-Check/Stock-Check-SCHURTER Wire length: 150 mm Suffix "21" corresponds to the version with V-Lock mating cordset. The connector is equipped with a notch intended for use with the latching cordset. The cord latching system prevents against accidental removal of the cordset. Available only for screw-on versions. Packaging unit 20 Pcs Accessories Description Wire Harness Wire harness for SCHURTER products Assorted Covers Rear Cover 0859.0047 Cord retaining kits Cord retaining strain relief Countersunk, K Flat head, L 4 Connectors 4700.0010 4700.0011 █ C20F Power Entry Modules with Line Filter www.schurter.com/PG06 Mating Outlets/Connectors Category / Description Connector Overview complete IEC Connector C19, Rewireable, Straight 4795 IEC Connector C19, Rewireable, Angled 4790 IEC Connector C19, Rewireable, Straight 0104U Connector further types to C20F Mating Outlets/Connectors shuttered Power Cord Overview complete Overview Power Cord with IEC Appliance Connector C19, V-Lock, straight VAC19KS Power Cord further types to C20F 24.08.2015 The specifications, descriptions and illustrations indicated in this document are based on current information. All content is subject to modifications and amendments. Information furnished is believed to be accurate and reliable. However, users should independently evaluate the suitability and test each product selected for their own applications. Connectors 5