C20F.0001

C20F
Power Entry Modules with Line Filter
www.schurter.com/PG06
IEC Appliance Inlet C20 with Filter, Front or Rear Side Mounting
Screw-on mounting
from front side
Standard- or Medical-Filter
Snap-in mounting
from front side
Screw-on mounting
from rear side
with wires (stranded)
C20
70° C
Description
Characteristics
Approvals
Other versions on request
-Panel Mount:
Screw-on version from front or rear side, snap-in version from front
side
-2 Functions:
Appliance Inlet Protection class I, Line filter in standard and medical
version
-Solder, quick connect or wires (stranded)
-VDE Certificate Number: 104884
-UL File Number: E72928
-Compact design with optimal shielding
Suitable for assembly in metal plated plastic housings
-Version with class X1 and X2 (standard version) capacitors
-Universal line filter for standard applications
Designed for standard and medical applications
-Suitable for use in equipment according to IEC/UL 60950
Suitable for use in medical equipment according to IEC/UL 60601-1
-16A according to UL
-Capacity CX 330 nF
References
Alternative: version without line filter 4793; 4798 Weblinks
pdf-datasheet, html-datasheet, General Product Information, Approvals,
CE declaration of conformity, RoHS, CHINA-RoHS, REACH, Mating
Connectors, e-Shop, SCHURTER-Stock-Check, Distributor-StockCheck, CAD-Drawings, Accessories, Wire Harnessing, Detailed request
for product
Newly available variants corresponding to V-Lock mating cordset. The connector is equipped with a notch intended for use with the latching cordset.
The cord latching system prevents against accidental removal of the cordset.
Technical Data
Ratings IEC
Ratings UL/CSA
Leakage Current
Dielectric Strength
Impulse Withstand Voltage
Allowable Operation Temp.
Climatic Category
Degree of Protection
Protection Class
Terminal
Panel Thickness s
Material: Housing
16 A @ Ta 40 °C / 250 VAC; 50 Hz
20 A @ Ta 40 °C / 250 VAC; 60 Hz
standard < 0.5 mA (250 V / 60 Hz)
medical < 5 µA (250 V / 60 Hz)
> 1.7 kVDC between L-N
> 2.7 kVDC between L/N-PE
Test voltage (2 sec)
> 2.5 kV between L-N (CX2)
> 4 kV between L-N (CX1)
> 5 kV between L/N-PE (Cy2)
voltage (1.2/50 μs)
-25 °C to 85 °C
25/085/21 acc. to IEC 60068-1
from front side IP 40 acc. to IEC 60529
Suitable for appliances with protection
class I acc. to IEC 61140
Solder, quick connect or wires (stranded)
Screw: max 8 mm
Mounting screw torque max 0.5 Nm
Snap-in: 1 mm to 3 mm
Thermoplastic, black, UL 94V-0
Appliance-Inlet/-Outlet
Line Filter
MTBF
C20 acc. to IEC 60320,
UL 498, CSA C22.2 no. 42 (for cold
conditions) pin-temperature 70 °C, 16 A,
Protection Class I
Standard and Medical Version, IEC
60939, UL 1283, CSA C22.2 no. 8
Technical Details
> 3'000'000 h acc. to MIL-HB-217 F
Connectors
1
C20F
Power Entry Modules with Line Filter
www.schurter.com/PG06
Dimension
Screw-on mounting from front side
10.3
R6
6.3 x 0.8 *
3.5/M3
64.65
30
3.85
42 ±0.15
34.8 +0.20
0
ø 6x80°
33.90
x 25.90
53
42
3.4
9.4
R3
26.8
+0.20
0
78.8
* Solder terminal: identical outer dimensions
Screw-on mounting from rear side with metal flange
3
10.3
R6
3.5
max. R 0.5
M3
28
64.65
30
78.8
42 ±0.15
33.90
x 25.90
53
36
42
R 0.5
36.4 +0.20
0
9.4
3.85
28.3
+0.20
0
Snap-in mounting from front side
10.3
38
33.90
x 25.85
34.8 +0.20
0
9.4
R2
64.65
30
3.85
78.8
Technical Data of Filter-Components
Rated Current
[A]
16
Filter-Type
Standard Version
Inductances
L [mH]
Capacitance
CX [nF]
Capacitance
CY [nF]
R [MΩ]
2 x 0.3
100
2.2
1
16
Medical Version (M5)
2 x 0.3
100
-
1
16
Medical Version (M80)
2 x 0.3
100
0.47
1
2
Connectors
R3
26.3
+0.20
0
C20F
Power Entry Modules with Line Filter
www.schurter.com/PG06
Diagrams
Standard or medical version (M80)
Medical version (M5)
L
L’
L
L’
L1
1) PE
Cx
L1
Cy
R
L2
N
Cy
PE’ 2)
1) PE
N’
1) Line
2) Load
Cx
PE’ 2)
R
L2
N
N’
1) Line
2) Load
Attenuation Loss
- - - - differential mode _____ common mode
Standard version
20 A
Medical version (M5)
20 A
All Variants
Rated Current
IEC [A]
Rated Current Filter-Type
UL [A]
Panel mounting
Mounting side
Terminal
Capacitor
Order Number
16
20
Standard Version
Snap-in
Front Side
Quick connect terminals 6.3 x 0.8
X2 100nF
C20F.0111
16
20
Standard Version
Snap-in
Front Side
Quick connect terminals 6.3 x 0.8
X1 100nF
C20F.0113
16
20
Standard Version
Snap-in
Front Side
Solder terminals
X2 100nF
C20F.0011
16
20
Standard Version
Snap-in
Front Side
Solder terminals
X1 100nF
C20F.0013
16
20
Standard Version
Screw
Front Side
Quick connect terminals 6.3 x 0.8
X2 100nF
C20F.0101
16
20
Standard Version
Screw
Front Side
Quick connect terminals 6.3 x 0.8
X2 100nF
C20F.0101.21
16
20
Standard Version
Screw
Front Side
Quick connect terminals 6.3 x 0.8
X1 100nF
C20F.0103
16
20
Standard Version
Screw
Front Side
Solder terminals
X2 100nF
C20F.0001
16
20
Standard Version
Screw
Front Side
Solder terminals
X2 100nF
C20F.0001.21
16
20
Standard Version
Screw
Front Side
Solder terminals
X1 100nF
C20F.0003
16
20
Standard Version
Screw
Rear Side
Flexible wire AWG14
X2 100nF
C20F.0221
16
20
Standard Version
Screw
Rear Side
Flexible wire AWG14
X1 100nF
C20F.0223
16
20
Standard Version
Screw
Rear Side
Quick connect terminals 6.3 x 0.8
X2 100nF
C20F.0121
16
20
Standard Version
Screw
Rear Side
Quick connect terminals 6.3 x 0.8
X1 100nF
C20F.0123
16
20
Standard Version
Screw
Rear Side
Solder terminals
X2 100nF
C20F.0021
16
20
Standard Version
Screw
Rear Side
Solder terminals
X1 100nF
C20F.0023
16
20
Medical Version (M5)
Snap-in
Front Side
Quick connect terminals 6.3 x 0.8
X2 100nF
C20F.0112
16
20
Medical Version (M5)
Snap-in
Front Side
Quick connect terminals 6.3 x 0.8
X1 100nF
C20F.0114
Connectors
█
█
█
3
C20F
Rated Current
IEC [A]
Power Entry Modules with Line Filter
www.schurter.com/PG06
Rated Current Filter-Type
UL [A]
Panel mounting
Mounting side
Terminal
Capacitor
Order Number
16
20
Medical Version (M5)
Snap-in
Front Side
Solder terminals
X2 100nF
C20F.0012
16
20
Medical Version (M5)
Snap-in
Front Side
Solder terminals
X1 100nF
C20F.0014
16
20
Medical Version (M5)
Screw
Front Side
Quick connect terminals 6.3 x 0.8
X2 100nF
C20F.0102
16
20
Medical Version (M5)
Screw
Front Side
Quick connect terminals 6.3 x 0.8
X1 100nF
C20F.0104
16
20
Medical Version (M5)
Screw
Front Side
Solder terminals
X2 100nF
C20F.0002
16
20
Medical Version (M5)
Screw
Front Side
Solder terminals
X1 100nF
C20F.0004
16
20
Medical Version (M5)
Screw
Rear Side
Flexible wire AWG14
X2 100nF
C20F.0222
16
20
Medical Version (M5)
Screw
Rear Side
Flexible wire AWG14
X1 100nF
C20F.0224
16
20
Medical Version (M5)
Screw
Rear Side
Quick connect terminals 6.3 x 0.8
X2 100nF
C20F.0122
16
20
Medical Version (M5)
Screw
Rear Side
Quick connect terminals 6.3 x 0.8
X1 100nF
C20F.0124
16
20
Medical Version (M5)
Screw
Rear Side
Solder terminals
X2 100nF
C20F.0022
16
20
Medical Version (M5)
Screw
Rear Side
Solder terminals
X1 100nF
C20F.0024
█ Most Popular.
Availability for all products can be searched real-time:http://www.schurter.com/en/Stock-Check/Stock-Check-SCHURTER
Wire length: 150 mm
Suffix "21" corresponds to the version with V-Lock mating cordset. The connector is equipped with a notch intended for use with the latching cordset. The cord latching system prevents against accidental removal of the cordset. Available only for screw-on versions.
Packaging unit 20 Pcs Accessories
Description
Wire Harness
Wire harness for SCHURTER products
Assorted Covers
Rear Cover
0859.0047
Cord retaining kits
Cord retaining strain relief
Countersunk, K
Flat head, L
4
Connectors
4700.0010
4700.0011
█
C20F
Power Entry Modules with Line Filter
www.schurter.com/PG06
Mating Outlets/Connectors
Category / Description
Connector Overview complete
IEC Connector C19, Rewireable, Straight
4795
IEC Connector C19, Rewireable, Angled
4790
IEC Connector C19, Rewireable, Straight
0104U
Connector further types to C20F
Mating Outlets/Connectors shuttered
Power Cord Overview complete
Overview Power Cord with IEC Appliance Connector C19, V-Lock, straight
VAC19KS
Power Cord further types to C20F
24.08.2015
The specifications, descriptions and illustrations indicated in this document are based on current
information. All content is subject to modifications and amendments. Information furnished is believed
to be accurate and reliable. However, users should independently evaluate the suitability and test each
product selected for their own applications.
Connectors
5