30-F206NBA200SA-M295L33 DC Boost Application

30-F206NBA200SA-M295L33
preliminary datasheet
DC Boost Application
flowBOOST2
600V/200A
General conditions
Boost
VGEon
VGEoff
Rgon
Rgoff
Vin
=
=
=
=
=
15 V
0V
2Ω
2Ω
Vinpk*sinωt
IGBT
Figure 1
FWD
Figure 2
Typical average static loss as a function of input current
Ploss = f(Iin)
Typical average static loss as a function of input current
Ploss = f(Iin)
120
Ploss (W)
Ploss (W)
80
100
Vinpk/Vout=1
Vinpk/Vout
=0.1
80
60
● 30-F206NBA200SA-M295L33
60
40
40
20
20
Vinpk/Vout=1
0
Vinpk/Vout
=0.1
0
0
40
80
120
160
0
I in (A)
At
Tj =
150
At
Tj =
°C
Vinpk / Vout from 0,1 to 1 in steps of 0,1
40
150
80
120
I in (A)
160
°C
Vinpk / Vout from 0,1 to 1 in steps of 0,1
IGBT
Figure 3
Typical average switching loss
as a function of input current
FWD
Figure 4
Typical average switching loss
as a function of input current
Ploss = f(Iin)
400
Ploss = f(Iin)
Ploss (W)
Ploss (W)
150
fsw="to"kHz
120
300
fsw="to"kHz
90
200
60
100
30
fsw= "from"kHz
fsw= "from"kHz
0
0
0
40
80
120
160
0
I in (A)
At
Tj =
150
At
Tj =
°C
DC link = 400
V
fsw from 8 kHz to 64 kHz in steps of factor 2
copyright by Vincotech
40
150
80
120
I in (A)
160
°C
DC link = 400
V
fsw from 8 kHz to 64 kHz in steps of factor 2
1
Revision: 1
30-F206NBA200SA-M295L33
preliminary datasheet
DC Boost Application
flowBOOST2
per PHASE
Figure 5
Typical available input current
as a function of Vinpk / Vout
600V/200A
per PHASE
Figure 6
Typical available input current
as a function of switching frequency
Iin = f(Vinpk/Vout)
120
Iin = f(fsw)
Iin(A)
Iin (A)
160
140
100
Th=60°C
120
80
100
60
80
60
Th=60°C
40
Th=100°C
40
Th=100°C
20
20
0
0
0,0
0,2
0,4
0,6
0,8
1,0
Vi npk /V out
1,2
10
100
At
Tj =
150
°C
At
Tj =
DC link =
fsw =
400
64
V
kHz
DC link = 400
Vinpk/Vout = 0,8
Th from 60 °C to 100 °C in steps of 5 °C
150
f sw (kHz)
1000
°C
V
Th from 60 °C to 100 °C in steps of 5 °C
per PHASE
Figure 7
Typical available input current
as a function of switching frequency
0,10
Iin = f(fsw)
Iin(A)
160
Vinpk/Vout
0,20
per PHASE
Figure 8
Typical available input current as a function of
of Vinpk / Vout and switching frequency
Iin = f(fsw, Vinpk/Vout)
140
0,30
Iin (A)
120
120,0-140,0
0,40
100
100,0-120,0
0,50
80,0-100,0
80
0,60
60,0-80,0
40,0-60,0
60
0,70
Th=60°C
20,0-40,0
40
0,80
0,0-20,0
Th=100°C
0,90
4
8
16
32
64
20
1,00
128
0
10
f sw (kHz)
100
At
Tj =
150
°C
At
Tj =
DC link =
Th =
400
80
V
°C
DC link = 400
Vinpk/Vout = 0,40
150
f sw (kHz)
1000
°C
V
Th from 60 °C to 100 °C in steps of 5 °C
copyright by Vincotech
2
Revision: 1
30-F206NBA200SA-M295L33
preliminary datasheet
DC Boost Application
flowBOOST2
600V/200A
per PHASE
Figure 9
Typical available electric input power as a function of
Pin = f(Th)
heatsink temperature
Pin (kW)
40
"from"kHz
30
20
"to"kHz
10
0
60
At
Tj =
70
150
DC link = 400
Vinpk/Vout = 0,8
80
90
Th ( o C)
100
°C
V
kHz
fsw from 8 kHz to 64 kHz in steps of factor 2
copyright by Vincotech
3