October 12, 2006 219 SERIES CURRENT SENSE INDUCTORS 40Hz TO 20kHz Features z z z z z Designed to meet large Secondary Saturation Voltage Accurate Turns Ratio High Dielectric Strength Capacity 2500VRMS Fully molded construction with center thru hole for Primary Load Tinned Leads with Leaded Solder is Available (note 2) ELECTRICAL SPECIFICATIONS AT 25ºC I Peak AMP Part Number PT21901 PT21903 PT21905 PT21906 PT21907 PT21925 PT21926 3.5 5.0 10.0 15.0 20.0 25.0 30.0 Volt Per AMP Rated Terminating Ohms (Nominal) 0.20 0.20 0.10 0.05 0.025 0.10 0.10 200 200 200 100 50 100 100 R.C.F. at 100% IP 100.0 100.0 100.0 100.0 100.0 100.0 100.0 Outline Dimensions 10% IP 102.80 101.37 100.87 100.40 100.30 100.90 100.80 L 0.625 0.625 0.625 0.625 0.625 1.375 1.375 W 0.625 0.625 0.625 0.625 0.625 0.625 0.625 H 0.625 0.625 0.625 0.625 0.625 1.375 1.375 ID 0.188 0.188 0.188 0.188 0.188 0.500 0.500 X 0.5 0.5 0.5 0.5 0.5 1.0 1.0 Notes: 1. 2. 3. Please consult factory for additional or custom requirements. For non-RoHS parts, replace PT prefix with 42- (e.g. PT12910 becomes 42-12910). Terminal finish is compliant to RoHS requirements 1 ID H 3 2 2 2 3 1 SCHEMATIC 1.000 TYP Ø .030 TYP X/2 X/2 W Y L DATATRONIC: 28151 Highway 74, Romoland, CA 92585 Tel: 951-928-7700 Toll Free Tel: 888-889-5391 Fax: 951-928-7701 Email: [email protected] 499 King’s Road, Hong Kong Tel: (852) 2562 3858, (852) 2564 8477 Fax: (852) 2565 7214, (852) 2563 1290 All specifications are subject to change without notice. Y 0.40 0.40 0.40 0.40 0.40 0.50 0.50