Datasheet SAFESERIES SIL RELAYS SCS Series NEW Safe control of back-up systems The monitoring circuit option takes inputs from 24 to 230 V AC/DC and the safety relay is intended for use in back-up systems or storage tank overfill prevention. Safe control of burner operation Fuel flow to the burner may be cut-off in a boiler alarm condition. SAFESERIES offers a SIL3 fuel cut-off relay which interfaces with the burner management controls. Safe use in corrosive environments The SIL3 relay is also available with a G3 coating, which makes it especially suitable for use in aggressive environmental conditions. Safe activation and deactivation This flexible safety relay can be used in either energize-to-safe or de-energizeto-safe mode. This makes it suitable for use both with actuators which should be powered-on under safe conditions or those which should be powered-off. Weidmuller’s single and dual channel DIN rail-mounted SCS Series are relay modules suitable for switching safety related circuits up to SIL3 level according to IEC 61508, for high risk installations. Typical applications include safety interlocks for burner management systems, over-fill controls for bulk liquid storage tanks and plant shut-down systems. The SCS Series is part of Weidmuller’s broad range of high reliability electronics and electrical connectivity products which services process industries and factory automation systems worldwide. • • • • • SIL relays for process Emergency Shut-Down systems Certified cULus and to IEC 61508 for SIL3 (TÜV) Energized or de-energized to safe modes Single and two-channel models Monitoring options with wide-range input voltage Weidmuller, Canada 10 Spy Court Markham, Ontario L3R 5H6 Telephone: (800) 268-4080 Facsimile: (877) 300-5635 Email: [email protected] Website: www.weidmuller.ca Weidmuller, Mexico Blvd. Hermanos Serdán 698, Col. San Rafael Oriente Puebla, Puebla, Mexico C.P. 72029 Telephone: 01 222 2686267 Facsimile: 01 222 2686219 Email: [email protected] Website: www.weidmuller.com.mx Weidmuller, United States 821 Southlake Blvd. Richmond, Virginia 23236 Telephone: (800) 849-9343 Facsimile: (804) 379-2593 Email: [email protected] Website: www.weidmuller.com SAFESERIES SIL relays SIL3 relays The SCS 24VDC P1SIL3DS safety relay is used in areas that require a functionally safe shutdown. This component The V DC P1SIL3DS safetySIL relay fulfillsSCS the 24 requirements of IEC 61508, 3. is used SCS 24 V DC P1SIL3DS •W ith and without monitoring circuit •W ide-range input voltage in the monitoring circuit •E xternally accessible fuse •T ÜV certified “Safety Approved“ •S IL3 rated when internal or external output fuse used in areas that require a functionally safe shutdown. This component fulfills the requirements of IEC 61508, SIL3. cULus Listed to UL 508 and CSA C22.2 No.14 under file E223474. Monitor IN Safety OUT max. 240 V AC switching voltage Technical data Ordering data Note 2 with monitoring without monitoring with monitoring and G3 gas-corrosion resistant 13 14 T 24 V UC...230 V UC 15 M1 M2 5A T -25...+50 °C -40...+85 °C Monitor Yes (art. No.: 1304040000 only) 24 V DC ± 20% 35 mA 42 mA LED yellow Relay Output A1 24 V AC/DC…230 V AC/DC ±10 % 23 mA @ 24 V DC, 4,4 mA @ 230 V AC LED yellow A2 +24 V 0 V Logic Input 21 22 24 max. 24 V DC switching voltage 1303890000 SCS 24VDC P1SIL3DS NO contact 5 A (refer to derating curve) 5 A (refer to derating curve) 250 V AC / 30 V DC 8A 12 V / 10 mA 2000 VA typ. 7 ms Ag Ni 0.15 5 A time-lag 5 A time-lag No 1304040000 SCS 24VDC P1SIL3DC MG3 6 Derating curve 5 4 3 CO contact 24 V DC 30 A 1 V / 1 mA AgNi 5µm Au typ. 17 ms No Load current in A 2 300 V ≥ 5.5 mm ≥ 5.5 mm 1.2 kVeff / 1 min. 1.2 kVeff / 1 min. 1.2 kVeff / 1 min. 6 kV (1.2/50 µs) III 2 1 0 0 114 EN 61000, EN 61326-3-2, EN 61508 / cULus, SIL3 1.5 / 0.13 / 2.5 114 / 22.5 / 117.2 Type Qty. SCS 24VDC P1SIL3DS M 1 SCS 24VDC P1SIL3DS 1 SCS 24VDC P1SIL3DS MG3 1 10 20 30 117.2 Part No. 1303760000 1303890000 1304040000 22.5 Temperatures Ambient temperature (operational) Storage temperature General data Noxious gas resistance to EN 60068-2-60 Input (safety circuit) Rated control voltage Guaranteed current consumption of 24 V DC -10 % Power consumption Status indicator Input (monitor circuit) Rated control voltage Current consumption Status indicator Output (safety circuit) Contact design Max. switching current, internal fuse Max. switching current, external fuse Max. permitted switching voltage Max. permitted switching current Min. switching power Max. switching power Switch-on time Base material of the contact Internal fuse External back-up fuse Short-circuit-proof Output (monitor circuit) Contact design Max. permitted switching voltage Max. allowed switching current Min. switching capacity Contact base material Switch-on time Short circuit resistant Insulation coordination (EN 50178) Rated voltage Creepage and clearance distance input – output Creepage and clearance distance output – output Dielectric strength input – output Dielectric strength output – output Dielectric strength to mounting rail Impulse withstand voltage Surge voltage category Pollution severity Further details of approvals / standards Standards / Approvals Dimensions Clamping range (nominal / min. / max.) mm² Depth x width x height mm Note Field 40 50 60 Ambient temperature in °C SAFESERIES SIL relays SIL3 relays SCS 24 V DC P2SIL3DSES •E nergized / de-energized to safe •T est inputs for testing the relay contacts •E xternally accessible fuse •T ÜV certified “Safety Approved“ •S IL3 rated when internal or external output fuse used The safety relay SCS 24 V DC P2SIL3DSES is used in areas that require functionally safe deactivation or activation. The requirements according to IEC 61508, SIL3 can be fulfilled with this module. The safety relay SCS 24VDC P2SIL3DSES is used in areas that require functionally safe deactivation or activation. The requirements according to IEC 61508, SIL3 can be fulfilled with this module. Technical data Note Ordering data Note Safety OUT max. 240 V AC switching voltage 24 V DC -15 / +20% 35 mA 45 mA LED yellow F 13 14 23 24 5A T 24 V DC LED red flashing: test input is triggered 2 1 x de-energized to safe (NO contact), 1 x energized to safe (NO contact) 5 A (refer to derating curve) 5 A (refer to derating curve) 250 V AC 8A 12 V / 10 mA 2000 VA < 5.5 ms (DTS), < 5 ms (ETS) Ag Ni 0.15 5 A time-lag 5 A time lag No TEST 1 RELAY OUTPUT A1 2 A2 X1 +24 V DC 0 V Logic Input X2 X3 +24 V DC 0 V Test Input 117.2 300 V ≥ 5.5 mm ≥ 5.5 mm 1.2 kVeff / 1 min. 1.2 kVeff / 1 min. 1.2 kVeff / 1 min. 6 kV (1.2/50 µs) III 2 114 Max. switching current, internal fuse Max. switching current, external fuse Max. permitted switching voltage Max. permitted switching current Min. switching power Max. switching power Switch-on time Base material of the contact Internal fuse External back-up fuse Short-circuit-proof Insulation coordination (EN 50178) Rated voltage Creepage and clearance distance input – output Creepage and clearance distance output – output Dielectric strength input – output Dielectric strength output – output Dielectric strength to mounting rail Impulse withstand voltage Surge voltage category Pollution severity Further details of approvals / standards Standards / Approvals Dimensions Clamping range (nominal / min. / max.) mm² Depth x width x height mm -25 °C...+50 °C -40 °C...+85 °C EN 61000, EN 61326-3-2, EN 61508 / SIL3 1.5 / 0.13 / 2.5 114 / 22.5 / 117.2 DTS (de-energized to safe) ETS (energized to safe) Type SCS 24VDC P2SIL3DSES Qty. 1 Part No. 1319270000 22.5 Temperatures Ambient temperature (operational) Storage temperature Input (safety circuit) Rated control voltage Guaranteed current consumption of 24 V DC -10 % Power consumption Status indicator Test inputs Rated control voltage Status indicator Number of test inputs Output (safety circuit) Contact design 3 SAFESERIES SIL relays SCS 24 V DC P2SIL3ES •P ositively-driven contacts •2 -channel design • Insert according to EN 50156 •T ÜV certified “Safety Approved“ Use where fuel flow to the burner may be cut-off in a boiler alarm condition. SAFESERIES model SCS 24 V DC P2SIL3ES offers a SIL3 fuel cut-off relay which interfaces with the burner management controls. Use where fuel flow to the burner may be cut-off in a boiler alarm condition. SAFESERIES model SCS 24VDC P2SIL3ES offers a SIL3 fuel cut-off relay which interfaces with the burner management controls. Technical data Input (supply) Rated control voltage Current consumption Guaranteed current consumption at 24 V DC -10 % Response time Status display Short-circuit detection Monitoring circuit Operating voltage Input Output (release circuit) Contact version Switching voltage AC, max. Max. permitted switching current Min. switching capacity Max. switching power Switch-on time Switch-off time Contact base material Max. switching current, external fuse External back-up fuse Feedback output Contact version Switching voltage AC, max. Max. switching current Insulation coordination (EN 50178) Rated voltage Creepage and clearance distance input – output Creepage and clearance distance output – output Dielectric strength input – output Dielectric strength output – output Dielectric strength to mounting rail Impulse withstand voltage Surge voltage category Pollution severity Further details of approvals / standards Standards / Approvals Dimensions Clamping range (nominal / min. / max.) mm² Depth x width x height mm Note Ordering data Note 4 -25 °C...+55 °C -40 °C...+85 °C 22 V DC, from internal power supply falling edge (button via S33/S34), rising edge (permanent bridge via S33/S35) 24 V DC ±15 % 55 mA (release circuit enabled), 6 mA (release circuit not enabled) 35 mA with bridge via C1/C2: typ. 50 ms, without bridge via C1/C2: typ. 20 ms LED green, power, LED yellow, signal Yes, max 4 s up to switch-off (Polyfuse) Safety OUT max. 240 V AC switching voltage 31 32 13 23 24 14 22 V DC, from internal power supply 2, each externally bridgeable 2 NO positively-driven (EN 50205) 250 V 6A 12 V / 10 mA 2000 VA 55 ms (C1/C2 bridged, switched via A1/A2), 30 ms (opening/closing of monitoring circuit) 20 ms (C1/C2 bridged, switched via A1/A2), 15 ms (opening/closing of monitoring circuit) AgSnO 5A 5 A time lag K1 POWER CH1 CH2 A1 A2 C1 C2 S33 S34 S35 S11 S12 S21 S22 +24 V DC 0 V Logic Input tr C1 C2 1 NC positively-driven (EN 50205 type B) 250 V 1A 300 V ≥ 5.5 mm ≥ 5.5 mm 1.2 kVeff / 1 min. 1.2 kVeff / 1 min. 1.2 kVeff / 1 min. 6 kV (1.2/50 µs) III 2 K2 Reset Auto Start Activation tr > 50 ms > 20 ms 117.2 114 Temperatures Ambient temperature (operational) Storage temperature Start circuit Operating voltage Function EN 61000, EN 61326-3-2, EN 61508 / SIL3 1.5 / 0.13 / 2.5 114 / 22.5 / 117.2 Type SCS 24VDC P2SIL3ES Qty. 1 Part No. 1319280000 22.5 SIL3 relays Subject to technical changes • 08/14 •1M • LIT1420