Wireless I/O Unidirectional Transmitter/Receiver Units — Introduction Unidirectional Transmitter/ Receiver Units – Introduction Wireless Input/Output (I/O) WirelessI/Oconnectsdirectlytoanalog,discreteandpulse transducersignals.Thesignalsaretransmittedbyradioand eitherre-createdasoutputsignals,oroutputviaseriallink orfield-bus. WeidmullerWirelessI/Ounitshavetheabilitytoform sophisticatedpeer-to-peernetworks,withevent-reporting messaging to optimize wireless density. Weidmuller products aredesignedforhighreliabilityoperationonopenlicensefreeradiobands. WI-I/O 9-L Unidirectional Transmitter/Receiver Units TheUnidirectionalWirelessI/Orangeofproductsissuitable forconnectingtoasinglesensororgroupofsensorsand providesaneconomicalsolutionforremotemonitoring systems.TheUnidirectionalLproductscanalsobeusedin morecomplexnetworksassignaltransmittersorreceivers. • Frequencyhoppingspreadspectrum902-928MHz1W license-freeUSA/Canada/Mexico • Configurablesub-bandslicense-freeSouthAmerica, Australia/NZ,Asia,Europe Applications • Wirelessconnectionofflowmetersorenergymeters • Monitoringstoragetanks • Monitoring cathodic protection on pipelines • Wirelessalarmsfrompowerreticulationfaultrelays Digital Analog Thermocouple Digital Analog Features Matched transmitter/receiver pair of modules, or individual transmitter and receiver units • Peer-to-peercommunications.Exceptionreporting. Reliableself-checkingmessages.Highlysecuredata encryption. • Multi-hoprepeaterfunctions-upto5intermediate unitscanbeconfiguredinanyinput-outputlink • FactoryconfiguredasamatchedTransmitter/Receiver pairoruser-configurablewithE-SeriesWindows configurationprogram 16 Transmitter unit • Input-onlytransmitterunit-twodigital/pulseinputs,one analog input and one thermocouple mV input • Transmits to Receiver unit as a matched pair where the inputsignalsarere-createdasoutputsignals,orcan transmit to a Multi-I/O or Gateway unit • Class1Div2hazardousareasapproval • Upto3000wirelessunitspernetwork • External inputs plus internally calculated values - analog setpointstatus,pulsecount,powersupplyvoltage • Thermocoupleinput–20to+100mVwithcold-junction compensationandlinearizationforJ,KorT-type • Setpointsstatusgeneratedbycomparinganaloginputto high and low setpoints • Digitalinputscanalsobeusedaspulsecountinputs • Powersupply9–30VDC,measuredandavailableasa transmittedvariable • 24VDCanalogloopsupplyinternallyprovided • RS232Configurationanddiagnosticsport C US Unidirectional Transmitter/Receiver Units — Introduction Receiver unit C Wireless I/O • Output-only receiver unit - three digital contact outputs and one analog output • ReceivesradiocommandsfromTransmitterunitasa matched pair where the input signals are re-created as outputsignals,orcanreceivecommandsfromaMulti-I/O or Gateway unit • Class1Div2hazardousareasapproval • Upto3000wirelessunitspernetwork • Powersupply9–30VDC;24VDCanalogloopsupply internally provided • Communicationsfailureindicationandconfigurable output • Outputscanbeconfiguredasretainedorreset(fail-safe) oncommunicationsfailure • LEDindicationofradiosignalstrength • RS232Configurationanddiagnosticsport US Transmitter/Receiver Unit Ordering Information Unit Description WI-I/O9-L-T WI-I/O9-L-R WI-I/O9-L-P1 WI-I/O9-L-P2 WirelessTransmitter(900MHz) WirelessReceiver(900MHz) 900MHzWirelessTransmitter/ReceiverPairwithtwo-2dBDipoleAntennas 900MHzWirelessTransmitter/ReceiverPairwithtwo0dBDipoleAntennas Dimensions • Humidity:0-99%RH • Regulatory Approvals:EMCcompliant89/336EEC, EN301489,AS3548,FCCPart15,ApprovedtoFCC Part15.247,RS210 • Housing:DIN-railthermo-plasticenclosure100x22x 120mm/3.9x0.9x4.7inches • Transmitter Unit:Power/OK,radioTX,DIN1,DIN2, analog set-point status • Receiver Unit:Power/OK,radioRX,DO1,DO2,DO3, communicationsfailLEDsalsousedtoprovideradio signal strength indication WI-I/O 9-L-T OK D1 D2 SP TX AZ PG 3.9" (100 mm) SET 6720005005 Transmitter Inputs 4.7" (120 mm) .09" (23mm) General • Frequency:frequencyhoppingspreadspectrum 902-928MHz,sub-bandsavailable,1W • Sensitivity:line-of-sightrange20miles(4WERP- “effectiveradiatedpower”),15km(1WERP);3000ft /1000minobstructedindustrialenvironments;radio distancescanbeincreasedbyupto5intermediate transceiver or gateway units • Antenna Connector:SMAconnectorforantennaor coaxialcableconnection • Temperature:-40to60°C/-40to140°F Input Type Digital PulseTotal Analog Thermocouple SetPoint Supply Voltage Source external external external external internal internal Function status count analog analog status analog InputvaluestransmittedasperWIB-net(seepage8)protocol-exceptionreportingonsignalchange,andupdatetime.Upto5repeateraddresses, configurable. 17 Unidirectional Transmitter/Receiver Units — Introduction Wireless I/O Digital / Pulse Inputs • Twoinputs,suitableforvoltage-freecontacts/NPN, orvoltageinput0-1VDCon/>3VDCoffpulseinput max.rate10Hz,50msecontime.Pulsecountedas 16-bitregister. Analog Inputs • 0-20mA(4-20mA) • “Floating”differentialinput,resolution16-bit, accuracy < 0.1 % Thermocouple Inputs • Millivolt(-20mVto+100mV),J,K,orTtype linearizationwithon-boardcold-junctioncompensation • Accuracybetterthan1°C Power Supply • Normal Supply: 9-30VDC,powerconsumption @12VDC-receivernormal70mA,max.250mA • Transmitternormal70mA,transmittingmax.600mA • Analogloopsupplyinternallygenerated,24VDC35mA • Internalmonitoringofsupplyvoltagemaybe transmitted as an “input” (transmitter unit only) Set-point Status • Highandlowset-pointsgenerateinternaldigitalstatus- set-point status sets (on) when analog value < low setpointandresets(off)whenanalogvalue>highset-point. Statusistransmittedasperdigitalinput,set-pointvalues aresetviathefrontpanelrotaryswitchorconfiguration software. • Separateset-pointsfor(4-20mA),thermocoupleand supplyinputsareconfigurable Receiver Outputs Digital Outputs • Threerelaycontactoutputs,260V1A Analog Outputs • 0-20mA,sourceoutput,12-bitresolution, 0.1% accuracy Communication Failure • Internalstatusbasedonconfigurabletime-outvalue • “Comms-fail”statuscanbeconfiguredtoalocaloutput Fail-Safe • On“comms-fail,”outputsuser-configurableasretained lastcorrectvalueorreset(fail-safe) 18 Serial Port • RS232RJ45femaleDCE,usedforconfiguration and diagnostics LED Indication Transmitter Unit • Power/OK,radioTX,DIN1,DIN2,analog set-point status Receiver Unit • Power/OK,radioRX,DO1,DO2,DO3, communicationsfail • LEDsalsousedtoprovideradiosignalstrength indication Configuration and Diagnostics • Factoryconfigurationtransmitter/receivermatched pair,AItoAO,2DIto2DO,SPstatustoDO3via RS232-RJ45cable • Userconfigurationviaserialport.Unidirectionalunits canbeconfiguredtonetworkwithmulti-I/Oand gateway units. • Diagnosticsfeatures:readinputvalues,writeoutput values,radiosignalstrength,monitorcommunication messages Unidirectional Transmitter/Receiver Units — 900 MHz C WI-I/O 9-L-R Receiver Wireless I/O WI-I/O 9-L-T Transmitter C1D2 US Technical Data Transmitter Inputs Digital Pulse Analog “floating”differentialinput: resolution accuracy Thermocouple Accuracy twoinputs,suitableforvoltagefreecontacts/NPN, orvoltageinput0-1VDCon/>3VDCoff maxrate10Hz,50msecontime. Pulsecountedas16bitregister. 0-20mA(4-20mA) 16bit < 0.1 % Millivolt(-20mVto+100mV),J,KorTtypelinearization withon-boardcold-junctioncompensation greaterthan1°C Receiver Outputs Digital Analog resolution accuracy Comms-Fail Fail-safe Power Supply Powerconsumption@12VDC Analogloopsupplyinternallygenerated Internalmonitoringofsupplylowvoltagestatus Powerconsumptionincreasesforpulseinputs>10Hz. Serial Port 9-30VDC Receiver100mA,Transmitter40mAquiescent, duringradiotransmission(50msec)300mA 24VDC30mA maybetransmittedasan“input”(Transmitterunitonly) threerelaycontactoutputs,260V1A 0-20mA 12bit 0.10% Internalstatusbasedonconfigurabletime-outvalue. Comms-failstatuscanbeconfiguredtoalocaloutput. On“comms-fail”,outputsuser-configurableasretained (lastcorrectvalue)orreset(fail-safe) 9-30VDC Receiver100mA,Transmitter40mAquiescent,during radiotransmission(50msec)300mA 24VDC30mA RS232RJ45femaleDCE,usedforconfiguration and diagnostics RS232RJ45femaleDCE,usedforconfiguration and diagnostics -40to60°C(-40to140°F) 0-99%RH FCCPart15.247,RS210 DIN-railmounting Power/OK,RadioTX,DIN1,DIN2,AnalogSetpointstatus -40to60°C(-40to140°F) 0-99%RH FCCPart15.247,RS210 DIN-railmounting General Data Operating Temperature Humidity EMC Standards Mounting LEDindication:TransmitterUnit LEDindication:ReceiverUnit frequencyhoppingspreadspectrum Transmit power Maximumlineofsightrange Antenna connector Dimensions mm (in) Configuration Diagnostics 902-928MHz,sub-bandsavailable 1W 20miles(4WERP),15km(1WERP);3000ft/ 1000minobstructedindustrialenvironments.Radio distancescanbeincreasedbyupto5intermediate repeaterunits.Eachtransmissionmaybeconfigured tobesent1to5times. SMAfemalecoaxial 100x23x120(3.9x0.9x4.7) Userconfigurationviaserialport.Unidirectionalunits canbeconfiguredtonetworkwithMulti-I/Oand Gateway units. Diagnosticsfeatures-readinputvalues,writeoutput values,radiosignalstrength,monitorcommunication messages. Power/OK,RadioRX,DO1,DO2,DO3,CommunicationsFail. 902-928MHz,sub-bandsavailable 1W 20miles(4WERP),15km(1WERP);3000ft/ 1000minobstructedindustrialenvironments.Radio distancescanbeincreasedbyupto5intermediate repeaterunits.Eachtransmissionmaybeconfigured tobesent1to5times. SMAfemalecoaxial 100x23x120(3.9x0.9x4.7) Userconfigurationviaserialport.Unidirectionalunits canbeconfiguredtonetworkwithMulti-I/Oand Gateway units. Diagnosticsfeatures-readinputvalues,writeoutput values,radiosignalstrength,monitorcommunication messages. Type Type Ordering Data Accessories:DB9Female-RJ45Serialconfigurationcable WI-I/O 9-L-T WI-CSER-RJ45 Part No. 6720005005 6720005108 WI-I/O 9-L-R WI-CSER-RJ45 Part No. 6720005006 6720005108 19 Wireless I/O Unidirectional Transmitter/Receiver Units — 900 MHz C WI-I/O 9-L-P1 Set - 1 Transmitter, 1 Receiver WI-I/O 9-L-P2 Set with 2 WI-ANT-DPL-0-8 twoinputs,suitableforvoltagefreecontacts/NPN, orvoltageinput0-1VDCon/>3VDCoff maxrate10Hz,50msecontime.Pulsecountedas16 bitregister. 0-20mA(4-20mA) twoinputs,suitableforvoltagefreecontacts/NPN,or voltageinput0-1VDCon/>3VDCoff maxrate10Hz,50msecontime.Pulsecountedas16 bitregister. 0-20mA(4-20mA) 16bit < 0.1 % Millivolt(-20mVto+100mV),J,KorTtypelinearization withon-boardcold-junctioncompensation greaterthan1°C threerelaycontactoutputs,260V1A 0-20mA 12bit 0.10% Internalstatusbasedonconfigurabletime-outvalue. Comms-failstatuscanbeconfiguredtoalocaloutput. On“comms-fail”,outputsuser-configurableasretained (lastcorrectvalue)orreset(fail-safe) 9-30VDC Receiver100mA,Transmitter40mAquiescent, duringradiotransmission(50msec)300mA 24VDC30mA maybetransmittedasan“input”(Transmitterunitonly) 16bit < 0.1 % Millivolt(-20mVto+100mV),J,KorTtypelinearization withon-boardcold-junctioncompensation greaterthan1°C threerelaycontactoutputs,260V1A 0-20mA 12bit 0.10% Internalstatusbasedonconfigurabletime-outvalue. Comms-failstatuscanbeconfiguredtoalocaloutput. On“comms-fail”,outputsuser-configurableasretained (lastcorrectvalue)orreset(fail-safe) 9-30VDC Receiver100mA,Transmitter40mAquiescent,during radiotransmission(50msec)300mA 24VDC30mA maybetransmittedasan“input”(Transmitterunitonly) RS232RJ45femaleDCE, usedforconfigurationanddiagnostics RS232RJ45femaleDCE, usedforconfigurationanddiagnostics -40to60°C(-40to140°F) 0-99%RH FCCPart15.247,RS210 DIN-railmounting Power/OK,RadioTX,DIN1,DIN2,AnalogSetpointstatus Power/OK,RadioRX,DO1,DO2,DO3, Communications Fail. 902-928MHz,sub-bandsavailable 1W 20miles(4WERP),15km(1WERP);3000ft/1000m inobstructedindustrialenvironments.Radiodistances canbeincreasedbyupto5intermediaterepeaterunits. Eachtransmissionmaybeconfiguredtobesent1to5 times. SMAfemalecoaxial 100x23x120(3.9x0.9x4.7) Factoryconfigurationtransmitter/receivermatched pair,AItoAO,2DIto2DO,SPstatustoDO3.User configurationviaserialport.Unidirectionalunitscanbe configuredtonetworkwithMulti-I/OandGatewayunits. Diagnosticsfeatures-readinputvalues,writeoutputvalues, radiosignalstrength,monitorcommunicationmessages. -40to60°C(-40to140°F) 0-99%RH FCCPart15.247,RS210 DIN-railmounting Power/OK,RadioTX,DIN1,DIN2,AnalogSetpointstatus Power/OK,RadioRX,DO1,DO2,DO3,CommunicationsFail. LEDsalsousedtoprovideradiosignalstrengthindication 902-928MHz,sub-bandsavailable 1W 20miles(4WERP),15km(1WERP);3000ft/1000m inobstructedindustrialenvironments.Radiodistances canbeincreasedbyupto5intermediaterepeaterunits. Eachtransmissionmaybeconfiguredtobesent1to5 times. SMAfemalecoaxial 100x23x120(3.9x0.9x4.7) Factoryconfigurationtransmitter/receivermatched pair,AItoAO,2DIto2DO,SPstatustoDO3.User configurationviaserialport.Unidirectionalunitscanbe configuredtonetworkwithMulti-I/OandGatewayunits. Diagnosticsfeatures-readinputvalues,writeoutputvalues, radiosignalstrength,monitorcommunicationmessages. Type Part No. WI-I/O9-L-P1 6720005007 •Two-2dBDipoleantennas(6720005086) •Two3ft.antennaconnectingcables/brackets •Oneconfigurationcable Type Part No. WI-I/O9-L-P2 6720005008 •Two0dBDipoleantennas(6720005080) •Two15ft.antennaconnectingcables/brackets •Oneconfigurationcable C1D2 US Technical Data Transmitter Inputs Digital Pulse Analog “floating”differentialinput: resolution accuracy Thermocouple Accuracy ReceiverOutputs Digital Analog resolution accuracy Comms-Fail Fail-safe Power Supply Powerconsumption@12VDC Analogloopsupplyinternallygenerated Internalmonitoringofsupplylowvoltagestatus Powerconsumptionincreasesforpulseinputs>10Hz. Serial Port General Data Operating Temperature Humidity EMC Standards Mounting LEDindication:TransmitterUnit LEDindication:ReceiverUnit frequencyhoppingspreadspectrum Transmit power Maximumlineofsightrange Antenna connector Dimensions mm (in) Configuration Diagnostics Ordering Data KitContents 20