1 5 W U l t r a m i n i a t ure Medical Grade Switching Power Supplies ASM15 series Universal 90-264VAC Input High Efficiency Regulated Outputs 4000VAC Isolation Single Output from 3.3 to 24 VDC 3”W x 2.18”L x 0.93”H Model Number Output Voltage Output Amps (max) (pk) ASM-1500 ASM-1501 ASM-1502 ASM-1503 ASM-1505 3.3 VDC 5 VDC 12 VDC 15VDC 24VDC 3.5A 3A 1.25A 1A 0.63A 3.8A 3.6A 1.5A 1.25A 0.75A WWW.ASTRODYNE.COM ASTRODYNE USA: 1-800-823-8082 ASTRODYNE PACIFIC: 886-2-26983458 ASM15 1 5 W U l t r a m i n i a t ure Medical Grade Switching Power Supplies INPUT SPECIFICATIONS Input Voltage Range Frequency Range Inrush Current, typ: Leakage Current PHYSICAL SPECIFICATIONS 90-264 VAC 47-63 Hz 20A @ 100VAC Input * 40A @ 200VAC Input * <0.3mA @ 264VAC, 50Hz OUTPUT SPECIFICATIONS Voltage and Current Load Regulation Line Regulation Preset Accuracy DC Voltage Adjust (typ) Temperature Coefficient Ripple/Noise Over Voltage Protection Over Temp. Protection Short Circuit Protection Hold Up Time series See Selection Chart +/- 3% (20% to 100% Load) Singles +/- 0.1~1%, typ 1% +/- 6% of FS (Primary) +/-0.03%/°C 100mV Pk-Pk, typ Clamp, 130-150% * Latching, Cool and Repower Continuous, self-recovering 20 mS, typ Size Construction Weight Connectors: Molex P/N: 3” x 2.18” x 0.93” Open Frame 2.5oz (70g) 50-37-5043 (Input) 50-37-5043 (Output) Contact: 08-70-1040 ENVIRONMENTAL SPECIFICATIONS Oper. Temperature Storage Temperature Relative Humidity EMC MTBF -10 to +50°C(FL) -25 to +71°C * 0 to + 95%, non-cond * EN55011 Class A 180,000 Hrs Mil Std 217, 25°C OUTPUT DERATING CURVE 100 90 80 GENERAL SPECIFICATIONS I/P-O/P: 4000VAC I/P-Ground: 2500VAC O/P-Ground: 1000VAC 75%~78%, typ 100Khz, (fixed, typical) ANSI/AAMI ES60601-1 3rd ed. CSA C22.2 No. 60601-1 3rd ed. EN60601-1 3rd ed. IEC60601-1 3rd ed. EN60601-1-2 All specifications are typical at nominal input, full load, and 25°C unless otherwise noted * These are stress ratings. Exposure of the devices to any of these conditions may adversely affect long term reliability. Proper operation under conditions other than the standard operating conditions is neither warranteed nor implied. WWW.ASTRODYNE.COM Load (%) Isolation Efficiency Switching Frequency Safety UL/cUL: UL-EU: CB: CE: 70 60 50 40 30 20 10 0 0 10 20 30 40 50 60 70 Ambient Temperature °C Astrodyne products are not authorized or warranteed for use as critical components in life support systems, equipment used in hazardous environments, nuclear controls systems, or other mission-critical applications. ASTRODYNE USA: 1-800-823-8082 ASTRODYNE PACIFIC: 886-2-26983458 A S M 1 5 series 15W U l t r a m i n i a t ure Medical Grade Switching Power Supplies MECHANICAL DIMENSIONS ���������������������������� ��� ���� 0.93 ���� max ���� 2.18 ���� max WWW.ASTRODYNE.COM ASTRODYNE USA: 1-800-823-8082 ASTRODYNE PACIFIC: 886-2-26983458