OFM5 series

OFM5
5 W U l t r a m i n i a t u re Open Frame Switchin g Power Supplies
series
Universal 90-264VAC Input
High Efficiency
Regulated Outputs
3000V Isolation
Single and Dual Outputs
UL60950-1, IEC60950-1 Approved
1.77”W x 2.28”L x 0.89”H
Model Number
Output Voltage
Output Amps(max)
(pk)
SINGLE OUTPUT
OFM-5000
OFM-5001
OFM-5002
OFM-5003
OFM-5005
3.3 VDC
5 VDC
12 VDC
15VDC
24VDC
1.25A
1A
0.42A
0.33A
0.23A
1.56A
1.5A
0.63A
0.5A
0.35A
DUAL OUTPUT
OFM-5006
OFM-5007
+/-12VDC
+/-15VDC
+/-0.21A
+/-0.17A
+/-0.26A
+/-0.21A
WWW.ASTRODYNE.COM
ASTRODYNE USA: 1-800-823-8082
ASTRODYNE PACIFIC: 886-2-26983458
OFM5
5 W U l t r a m i n i a t u re Open Frame Switchin g Power Supplies
GENERAL SPECIFICATIONS
INPUT SPECIFICATIONS
Input Voltage Range
Frequency Range
Inrush Current, typ:
90-264 VAC
47-440 Hz
20A@100V, 40A@200V Input *
OUTPUT SPECIFICATIONS
Voltage and Current
Load Regulation (20%-FL)
Line Regulation
Cross Regulation (Duals)
Preset Accuracy
DC Voltage Adjust (typ)
Temperature Coefficient
Ripple/Noise
Over Voltage Protection
Over Temp. Protection
Short Circuit Protection
Hold Up Time
series
See Selection Chart
Singles: +/- 3%, Duals: +/- 3%
Singles +/- 0.1~1%, typ
Duals +/- 0.3~1%, typ
2%
1%
+/- 6% of FS (Primary)
+/-0.03%/°C
100mV Pk-Pk, typ Clamp, 130-150% *
Latching, Cool and Repower
Continuous, self-recovering
20 mS, typ
All specifications are typical at nominal input, full load, and 25°C unless otherwise noted
* These are stress ratings. Exposure of the devices to any of these conditions
may adversely affect long term reliability. Proper operation under conditions
other than the standard operating conditions is neither warranteed nor implied.
WWW.ASTRODYNE.COM
Input-Out Isolation
I/P-Ground
O/P-Ground
Efficiency
Switching Frequency
Safety UL/cUL: UL-EU:
CE: CB: 3KVAC
2500VAC
1000VAC
75%~78%, typ
100Khz, (fixed, typical)
UL60950-1 2nd ed./
C22.2 60950-1 2nd ed.
EN60950-1 2nd ed.
EN60601-1-2
IEC60950-1 2nd ed. PHYSICAL SPECIFICATIONS
Size
Construction
Weight
1.77” x 2.28” x 0.89”
Open Frame
1.4oz (38g)
ENVIRONMENTAL SPECIFICATIONS
Oper. Temperature
Storage Temperature
Relative Humidity
EMC
MTBF 0 to +70°C (See Derate)
-25 to +71°C *
0 to + 95%, non-cond *
FCC/A, VDE 0871/A (Mil Std 217, 25°C)
180,000 Hrs
Astrodyne products are not authorized or warranteed for use
as critical components in life support systems, equipment used
in hazardous environments, nuclear controls systems, or other
mission-critical applications.
ASTRODYNE USA: 1-800-823-8082
ASTRODYNE PACIFIC: 886-2-26983458
O F M 5 series

5 W U l t r a m i n i a t u re Open Frame Switchin g Power Supplies
MECHANICAL
DIMENSIONS


†
WWW.ASTRODYNE.COM
 ­€‚ƒ„‚ƒ ‚…€‚ƒ„‚ƒ







ASTRODYNE USA: 1-800-823-8082
ASTRODYNE PACIFIC: 886-2-26983458
5 W U l t r a m i n i a t u re Open Frame Switchin g Power Supplies
OFM5
series
OUTPUT DERATING CURVE
100
90
Load, %
80
70
60
50
40
30
20
0
10
20
30
40
50
60
70
Ambient Temperature, °C
WWW.ASTRODYNE.COM
ASTRODYNE USA: 1-800-823-8082
ASTRODYNE PACIFIC: 886-2-26983458